ETE. Tatulli

E. Tatulli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


E. Tatulli has a total of 66 co-authors. Here are the top co-authors by number of shared publications:

  • A. Chelli

    Laboratoire d’Astrophysique, Observatoire de Grenoble, 38041 Grenoble Cedex, France

    3 shared publications
  • Leonardo Testi

    Alma Mater Studiorum – Università di Bologna, Dipartimento di Fisica e Astronomia “Augusto Righi

    2 shared publications
  • A. Delboulbé

    Lab. d'Astrophysique de l'Observatoire de Grenoble, Univ. J. Fourier, CNRS (France)

    1 shared publication
  • A. Natta

    INAF-Osservatorio Astrofisico di Arcetri, Istituto Nazionale di Astrofisica, Largo E. Fermi 5, 50125 Firenze, Italy

    1 shared publication
  • A. Natta

    INAF – Osservatorio Astrofisico di Arcetri, Largo E. Fermi 5, 50125 Firenze, Italy

    1 shared publication
  • Alain Chelli

    Laboratoire d'Astrophysique de Grenoble and Mariotti Center, UMR 5571 Université Joseph Fourier/CNRS, BP 53, 38041 Grenoble Cedex 9, France

    1 shared publication

Latest Publications

  • VSI: the VLTI spectro-imager

    by F. Malbet, D. Buscher, G. Weigelt, P. Garcia, M. Gai, D. Lorenzetti, J. Surdej, J. Hron, R. Neuhäuser, P. Kern, et al.

    The VLTI Spectro Imager (VSI) was proposed as a second-generation instrument of the Very Large Telescope Interferometer providing the ESO community with spectrally-resolved, near-infrared images at angular resolutions down to 1.1 milliarcsecond and spectral resolutions up to R = 12000. Targets as faint as K = 13 will be imaged without requiring a brighter nearby reference object; fainter targets can be accessed if a suitable reference is available. The unique combination of high-dynamic-range imaging at high angular resolution and high spectral resolution enables a scientific program which serves a broad user community and at the same time provides the opportunity for breakthroughs in many areas of astrophysics. The high level specifications of the instrument are derived from a detailed science case based on the capability to obtain, for the first time, milliarcsecond-resolution images of a wide range of targets including: probing the initial conditions for planet formation in the AU-scale environments of young stars; imaging convective cells and other phenomena on the surfaces of stars; mapping the chemical and physical environments of evolved stars, stellar remnants, and stellar winds; and disentangling the central regions of active galactic nuclei and supermassive black holes. VSI will provide these new capabilities using technologies which have been extensively tested in the past and VSI requires little in terms of new infrastructure on the VLTI. At the same time, VSI will be able to make maximum use of new infrastructure as it becomes available; for example, by combining 4, 6 and eventually 8 telescopes, enabling rapid imaging through the measurement of up to 28 visibilities in every wavelength channel within a few minutes. The current studies are focused on a 4-telescope version with an upgrade to a 6-telescope one. The instrument contains its own fringe tracker and tip-tilt control in order to reduce the constraints on the VLTI infrastructure and maximize the scientific return.


  • Open Access

    Spatially resolving the hot CO around the young Be star 51 Ophiuchi

    by E. Tatulli, F. Malbet, F. Ménard, C. Gil, L. Testi, A. Natta, S. Kraus, P. Stee, S. Robbe-Dubois

    Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics


  • Open Access

    Gas and dust in the inner disk of the Herbig Ae star MWC 758

    by A. Isella, E. Tatulli, A. Natta, L. Testi

    Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics


  • Fiber optic interferometry: statistics of visibility and closure phase

    by E. Tatulli, A. Chelli

    Interferometric observations with three telescopes or more provide two observables: closure phase information and visibility measurements. When single-mode interferometers are used, both observables have to be redefined in the light of the coupling phenomenon between the incoming wave front and the fiber. We introduce the estimator of both the so-called modal visibility and the modal closure phase. Then we compute the statistics of the two observables in the presence of partial correction by adaptive optics, paying attention to the correlation between the measurements. We find that the correlation coefficients are mostly zero and in any case are never greater than 1∕2 for the visibilities and 1∕3 for the closure phases. From this theoretical analysis, a data-reduction process using classic least-squares minimization is investigated. In the framework of the AMBER instrument, the three-beam recombiner of the Very Large Telescope Interferometer (VLTI), we simulate the observation of a single Gaussian source and study the performances of the interferometer in terms of diameter measurements. We show that the observation is optimized, i.e., that the signal-to-noise ratio (SNR) of the diameter is maximal when the FWHM of the source is roughly 1∕2 of the mean resolution of the interferometer. We finally point out that, in the case of an observation with three telescopes, neglecting the correlation between the measurements leads to overestimating the SNR by a factor of 2. We infer that in any case this value is an upper limit.


  • Open Access

    Single-mode versus multimode interferometry: A performance study

    by E. Tatulli, P. Mège, A. Chelli

    We compare performances of ground-based single-mode and multimode (speckle) interferometers in the presence of partial Adaptive Optics correction of atmospheric turbulence. It is first shown that for compact sources (i.e. sources smaller than the Airy disk of a single telescope) not entirely resolved by the interferometer, the remarkable property of spatial filtering of single-mode waveguides coupled with AO correction significantly reduces the speckle noise which arises from residual wavefront corrugations. Focusing on those sources, and in the light of the AMBER experiment (the near infrared instrument of the VLTI), we show that single-mode interferometry produces a better Signal-to-Noise Ratio on the visibility than speckle interferometry. This is true for bright sources (), and in any case as soon as Strehl ratio of 0.2 is achieved. Finally, the fiber estimator is much more robust – by two orders of magnitude – than the speckle estimator with respect to Strehl ratio variations during the calibration procedure. The present analysis theoretically explains why interferometry with fibers can produce visibility measurements with a very high precision, or less.


  • Open Access

    Single-Mode versus multimode interferometry: a performance study

    by E. Tatulli, P. Mege, A. Chelli

    We compare performances of ground-based single-mode and multimode (speckle) interferometers in the presence of partial Adaptive Optics correction of atmospheric turbulence. It is first shown that for compact sources (i.e. sources smaller than the Airy disk of a single telescope) not entirely resolved by the interferometer, the remarkable property of spatial filtering of single-mode waveguides coupled with AO correction significantly reduces the speckle noise which arises from residual wavefront corrugations. Focusing on those sources, and in the light of the AMBER experiment (the near infrared instrument of the VLTI), we show that single-mode interferometry produces a better Signal-to-Noise Ratio on the visibility than speckle interferometry. This is true for bright sources (K < 5), and in any case as soon as Strehl ratio of 0.2 is achieved. Finally, the fiber estimator is much more robust -- by two orders of magnitude -- than the speckle estimator with respect to Strehl ratio variations during the calibration procedure. The present analysis theoretically explains why interferometry with fibers can produce visibility measurements with a very high precision, 1% or less