Chengxun Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengxun Liu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Liesbet Lagae
Department of Physics and Astronomy KU Leuven Leuven Belgium
2 shared publications- Willem Van Roy
Imec, Kapeldreef 75, 3001 Leuven, Belgium
2 shared publications Alexandra Dusa
IMEC, Kapeldreef 75, 3001 Leuven, Belgium.
1 shared publication- Benjamin Jones
Interuniversitair Micro-Electronica Centrum (IMEC), Leuven, Belgium
1 shared publication Bivragh Majeed
IMEC, Kapeldreef 75, 3001 Leuven, Belgium.
1 shared publication- Camila Dalben Madeira Campos
IMEC, Leuven, Belgium
1 shared publication
Latest Publications
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Inertial focusing of neutrally buoyant spherical particle in shallow microchannels
This study investigates the lift force acting on a finite-size, neutrally buoyant spherical particle suspended in a liquid while flowing through a shallow channel at low Reynolds numbers. Using an immersed boundary method, we calculate the lift force for particle radius-to-channel height ratios spanning 0.03≤a/H≤0.35 in 2D planar Poiseuille flows. We propose an explicit formula that accurately predicts the lift force for particles as large as a/H=0.35 and remains valid for particle Reynolds number Rep≤1, despite a reduction in near-wall lift force at higher Rep. The influence of slip boundary conditions is also explored, demonstrating that increased slip length reduces near-wall lift force and shifts the particle equilibrium position closer to the wall. Predictions of the particle trajectory from the derived model are in good agreement with the published experimental data. These findings offer a practical framework for estimating the migration of large particles in microfluidic devices.
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Inertial focusing of neutrally buoyant spherical particle in shallow microchannels
This study investigates the lift force acting on a finite-size, neutrally buoyant spherical particle suspended in a liquid while flowing through a shallow channel at low Reynolds numbers. Using an immersed boundary method, we calculate the lift force for particle radius-to-channel height ratios spanning 0.03≤a/H≤0.35 in 2D planar Poiseuille flows. We propose an explicit formula that accurately predicts the lift force for particles as large as a/H=0.35 and remains valid for particle Reynolds number Rep≤1, despite a reduction in near-wall lift force at higher Rep. The influence of slip boundary conditions is also explored, demonstrating that increased slip length reduces near-wall lift force and shifts the particle equilibrium position closer to the wall. Predictions of the particle trajectory from the derived model are in good agreement with the published experimental data. These findings offer a practical framework for estimating the migration of large particles in microfluidic devices.
- 20 March 2026
- Published by Wiley in Electrophoresis
- Vol. 47 (5) , 396-405
A Continuum Modeling Approach to Nanoparticle Polarizability Characterization Using Fluorescence Intensity Profiles
The use of dielectrophoresis (DEP) for the manipulation of electrically polarizable particles has received a lot of interest in the past decades. Theories relying on the Clausius–Mossotti (CM) factor describe the DEP behavior of macroscale particles with great accuracy. However, under nanoscale conditions, these classical CM factor theories can break down. Therefore, experimental characterization of particle polarizabilities is of utmost importance. We present an integrated experimental–computational methodology that allows the quantification of effective particle polarizabilities from DEP experiments. The methodology is based on the comparison of experimental and simulated concentration profiles of fluorescent nanoparticles captured by a set of electrodes. We obtain effective particle polarizabilities for 52 and 105 nm particles that agree well with values predicted by CM theory. The considered particles hence serve as a calibration model for our approach, demonstrating that realistic particle polarizabilities can be obtained and paving the way for polarizability quantification for particles where existing theories are inadequate.
- 20 March 2026
- Published by Wiley in Electrophoresis
- Vol. 47 (5) , 396-405
A Continuum Modeling Approach to Nanoparticle Polarizability Characterization Using Fluorescence Intensity Profiles
The use of dielectrophoresis (DEP) for the manipulation of electrically polarizable particles has received a lot of interest in the past decades. Theories relying on the Clausius–Mossotti (CM) factor describe the DEP behavior of macroscale particles with great accuracy. However, under nanoscale conditions, these classical CM factor theories can break down. Therefore, experimental characterization of particle polarizabilities is of utmost importance. We present an integrated experimental–computational methodology that allows the quantification of effective particle polarizabilities from DEP experiments. The methodology is based on the comparison of experimental and simulated concentration profiles of fluorescent nanoparticles captured by a set of electrodes. We obtain effective particle polarizabilities for 52 and 105 nm particles that agree well with values predicted by CM theory. The considered particles hence serve as a calibration model for our approach, demonstrating that realistic particle polarizabilities can be obtained and paving the way for polarizability quantification for particles where existing theories are inadequate.
- 6 October 2023
- Published by Springer Nature in Biomedical Microdevices
- Vol. 25 (4) , 1-14
Use of high frequency electrorotation to identify cytoplasmic changes in cells non-disruptively
In this paper we demonstrate how the use of frequencies ranging from 50 kHz to 5 GHz in the analysis of cells by electrorotation can open the path to the identification of differences not detectable by conventional set-ups. Earlier works usually reported electrorotation devices operating below 20 MHz, limiting the response obtained to properties associated with the cell membrane. Those devices are thus unable to resolve the physiological properties in the cytoplasm. We used microwave-based technology to extend the frequency operation to 5 GHz. At high frequencies (from tens of MHz to GHz), the electromagnetic signal passes through the membrane and allows probing the cytoplasm. This enables several applications, such as cell classification, and viability analysis. Additionally, the use of conventional microfabrication techniques reduces the cost and complexity of analysis, compared to other non-invasive methods. We demonstrated the potential of this set-up by identifying two different populations of T-lymphocytes not distinguishable through visual assessment. We also assessed the effect of calcein on cell cytoplasmic properties and used it as a controlled experiment to demonstrate the possibility of this method to detect changes happening predominantly in the cytoplasm. Graphical Abstract
- 6 October 2023
- Published by Springer Nature in Biomedical Microdevices
- Vol. 25 (4) , 1-14
Use of high frequency electrorotation to identify cytoplasmic changes in cells non-disruptively
In this paper we demonstrate how the use of frequencies ranging from 50 kHz to 5 GHz in the analysis of cells by electrorotation can open the path to the identification of differences not detectable by conventional set-ups. Earlier works usually reported electrorotation devices operating below 20 MHz, limiting the response obtained to properties associated with the cell membrane. Those devices are thus unable to resolve the physiological properties in the cytoplasm. We used microwave-based technology to extend the frequency operation to 5 GHz. At high frequencies (from tens of MHz to GHz), the electromagnetic signal passes through the membrane and allows probing the cytoplasm. This enables several applications, such as cell classification, and viability analysis. Additionally, the use of conventional microfabrication techniques reduces the cost and complexity of analysis, compared to other non-invasive methods. We demonstrated the potential of this set-up by identifying two different populations of T-lymphocytes not distinguishable through visual assessment. We also assessed the effect of calcein on cell cytoplasmic properties and used it as a controlled experiment to demonstrate the possibility of this method to detect changes happening predominantly in the cytoplasm. Graphical Abstract
- 17 April 2018
- Published by Wiley in Cytometry Part A
- Vol. 93 (6) , 589-591
Microfluidic FACS becoming real
- 17 April 2018
- Published by Wiley in Cytometry Part A
- Vol. 93 (6) , 589-591
Microfluidic FACS becoming real
- 23 February 2017
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 17 (7) , 1287-1296
Micro vapor bubble jet flow for safe and high-rate fluorescence-activated cell sorting
High rate and safe cell sorting is enabled by rapid thermal bubble jet flow in a closed microfluidic chip.
- 23 February 2017
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 17 (7) , 1287-1296
Micro vapor bubble jet flow for safe and high-rate fluorescence-activated cell sorting
High rate and safe cell sorting is enabled by rapid thermal bubble jet flow in a closed microfluidic chip.