Kerstin Leopold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kerstin Leopold has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Paul J. Worsfold
University of Plymouth, UK
3 shared publications Michael Foulkes
2 shared publicationsMichael Schuster
Technische Universität München
2 shared publications- A. Zierhut
Technische Universität München
1 shared publication Anja Zierhut
Arbeitsgruppe für Analytische Chemie, Technische Universität München, Lichtenbergstrasse 4, Garching, Germany
1 shared publicationL. Harwardt
Technische Universität München
1 shared publication
Latest Publications
- 5 November 2010
- Published by Springer Nature
- p. 399-410
Pd Particles as Standardized Test Material for Bioavailability Studies of Traffic Related Pd Emissions to Barley Plants
- 5 November 2010
- Published by Springer Nature
- p. 399-410
Pd Particles as Standardized Test Material for Bioavailability Studies of Traffic Related Pd Emissions to Barley Plants
- Top Cited Papers
- 1 March 2010
- Published by Elsevier in Analytica Chimica Acta
- Vol. 663 (2) , 127-138
Methods for the determination and speciation of mercury in natural waters—A review
- 1 March 2010
- Published by Elsevier in Analytica Chimica Acta
- Vol. 663 (2) , 127-138
Top Cited PapersMethods for the determination and speciation of mercury in natural waters—A review
- 28 January 2010
- Published by Springer Nature in Environmental Sciences Europe
- Vol. 22 (1) , 72-77
Reagenzienfreie Bestimmung von Quecksilberspuren in Wasserproben
- 28 January 2010
- Published by Springer Nature in Environmental Sciences Europe
- Vol. 22 (1) , 72-77
Reagenzienfreie Bestimmung von Quecksilberspuren in Wasserproben
- 31 March 2009
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (9) , 3421-3428
Gold-Coated Silica as a Preconcentration Phase for the Determination of Total Dissolved Mercury in Natural Waters Using Atomic Fluorescence Spectrometry
A novel solid-phase preconcentration method is reported, using in-house gold-coated silica adsorbent packed in a microcolumn, for the determination of dissolved mercury in natural waters by atomic fluorescence spectrometry (AFS). The adsorbent was prepared by chemical reduction of a Au(III) solution with hydroxylamine in the presence of suspended silica particles. The resulting Au nanoparticles on the silica surface were highly efficient for adsorbing different mercury species from acidified waters without additional reagents. The acidified aqueous samples were passed over the microcolumn, either incorporated in a fully automated flow injection (FI) system directly coupled to the AFS or as part of a portable FI system for in situ preconcentration. After rinsing and drying of the column, Hg0 was released by heating and directed to the AFS cell for quantification. The method offers significant advantages because no reagents are needed for species conversion, preconcentration, sample storage, or desorption and therefore the risk of contamination is minimized and blank values are lowered. This results in a low detection limit of 180 pg L−1 using a sample volume of only 7 mL and good reproducibility, with relative standard deviations 90% in spiked river waters (spiked [Hg] = 0, 1, 5, 10 ng L−1), and the experimental value for the certified reference material ORMS-4 (elevated mercury in river water) was 22.3 ± 2.6 ng Hg L−1 which was in good agreement with the certified value of 22.0 ± 1.6 ng Hg L−1 (recovery = 101%). The method was successfully applied to seven different natural waters and wastewaters ([Hg] 0.5−4.6 ng L−1) from south west England.
- 31 March 2009
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (9) , 3421-3428
Gold-Coated Silica as a Preconcentration Phase for the Determination of Total Dissolved Mercury in Natural Waters Using Atomic Fluorescence Spectrometry
A novel solid-phase preconcentration method is reported, using in-house gold-coated silica adsorbent packed in a microcolumn, for the determination of dissolved mercury in natural waters by atomic fluorescence spectrometry (AFS). The adsorbent was prepared by chemical reduction of a Au(III) solution with hydroxylamine in the presence of suspended silica particles. The resulting Au nanoparticles on the silica surface were highly efficient for adsorbing different mercury species from acidified waters without additional reagents. The acidified aqueous samples were passed over the microcolumn, either incorporated in a fully automated flow injection (FI) system directly coupled to the AFS or as part of a portable FI system for in situ preconcentration. After rinsing and drying of the column, Hg0 was released by heating and directed to the AFS cell for quantification. The method offers significant advantages because no reagents are needed for species conversion, preconcentration, sample storage, or desorption and therefore the risk of contamination is minimized and blank values are lowered. This results in a low detection limit of 180 pg L−1 using a sample volume of only 7 mL and good reproducibility, with relative standard deviations 90% in spiked river waters (spiked [Hg] = 0, 1, 5, 10 ng L−1), and the experimental value for the certified reference material ORMS-4 (elevated mercury in river water) was 22.3 ± 2.6 ng Hg L−1 which was in good agreement with the certified value of 22.0 ± 1.6 ng Hg L−1 (recovery = 101%). The method was successfully applied to seven different natural waters and wastewaters ([Hg] 0.5−4.6 ng L−1) from south west England.
- 12 March 2009
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (6) , 767-774
Activated gold surfaces for the direct preconcentration of mercury species from natural waters
This paper describes for the first time the mechanism of adsorption of different dissolved mercury species onto gold surfaces directly from aqueous solutions. The surface morphology of the gold collector is critical for the adsorption behaviour of the different mercury species. Smooth gold surfaces selectively trap elemental mercury (Hg0), whereas nano-structured gold surfaces quantitatively retain all dissolved mercury species (Hg0, Hg2+, and MeHg+) from aqueous solutions. The mechanism of Hg2+ and MeHg+ adsorption can be explained by the catalytic activity of the nano-structured gold surface, whereas Hg0 adsorption is an amalgamation process. Nano-structured gold surfaces can easily be generated from gold collectors with smooth surfaces by adsorbing and thermally desorbing Hg0. Both types of gold collectors, selective collectors (smooth surface) for species specific trapping of Hg0 and active collectors (nano-structured) for the preconcentration of all Hg species can be used for quantitative analysis with recoveries of 97.0 ± 6.8% in ocean water after thermal desorption at 700 °C and atomic fluorescence spectrometric detection. This preconcentration method for the determination of total dissolved mercury in natural waters offers significant advantages over existing methods because no reagents are needed for sample pre-treatment, preconcentration or desorption and therefore the risk of contamination is minimized and blank values are lowered. This results in low detection limits for Hg2+ and MeHg+ of 101 pg L−1 and 144 pg L−1, respectively, using a sample volume of only 7 mL, and good reproducibility, with uncertainties less than 3.7% (n = 5). In addition the preparation of the active phases is very straightforward.
- 12 March 2009
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (6) , 767-774
Activated gold surfaces for the direct preconcentration of mercury species from natural waters
This paper describes for the first time the mechanism of adsorption of different dissolved mercury species onto gold surfaces directly from aqueous solutions. The surface morphology of the gold collector is critical for the adsorption behaviour of the different mercury species. Smooth gold surfaces selectively trap elemental mercury (Hg0), whereas nano-structured gold surfaces quantitatively retain all dissolved mercury species (Hg0, Hg2+, and MeHg+) from aqueous solutions. The mechanism of Hg2+ and MeHg+ adsorption can be explained by the catalytic activity of the nano-structured gold surface, whereas Hg0 adsorption is an amalgamation process. Nano-structured gold surfaces can easily be generated from gold collectors with smooth surfaces by adsorbing and thermally desorbing Hg0. Both types of gold collectors, selective collectors (smooth surface) for species specific trapping of Hg0 and active collectors (nano-structured) for the preconcentration of all Hg species can be used for quantitative analysis with recoveries of 97.0 ± 6.8% in ocean water after thermal desorption at 700 °C and atomic fluorescence spectrometric detection. This preconcentration method for the determination of total dissolved mercury in natural waters offers significant advantages over existing methods because no reagents are needed for sample pre-treatment, preconcentration or desorption and therefore the risk of contamination is minimized and blank values are lowered. This results in low detection limits for Hg2+ and MeHg+ of 101 pg L−1 and 144 pg L−1, respectively, using a sample volume of only 7 mL, and good reproducibility, with uncertainties less than 3.7% (n = 5). In addition the preparation of the active phases is very straightforward.