Ulrich Tallarek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ulrich Tallarek has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Henk Van As
Laboratory of Biophysics , Wageningen University , Stippeneng 4 , 6708 WE Wageningen , The Netherlands
4 shared publications - Erdmann Rapp
Bioprocess Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany
3 shared publications Ernst Bayer
Forschungsstelle für Nukleinsäure‐ und Peptidchemie Institut für Organische Chemie der Universität Tübingen Auf der Morgenstelle 18, 72076 Tübingen, Deutschland
3 shared publications- Dagmar van Dusschoten
Department of Molecular Physics & Wageningen NMR Centre, Wageningen Agricultural University, Dreijenlaan 3, NL‐6703 HA Wageningen (The Netherlands)
1 shared publication - Ernst Bayer
Institut für Organische Chemie der Universität Tübingen, Auf der Morgenstelle 18, D-72076 Tübingen, Germany
1 shared publication Georges Guiochon
Department of Chemistry, University of Tennessee at Knoxville, Knoxville, TN 37996‐1600 (USA) (and) Chemical and Analytical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (USA)
1 shared publication
Latest Publications
- 4 May 2001
- Published by Wiley in Angewandte Chemie
- Vol. 113 (9) , 1741-1745
Untersuchungen zur elektroosmotischen Perfusion in kapillaren Festbetten
- 4 May 2001
- Published by Wiley in Angewandte Chemie
- Vol. 113 (9) , 1741-1745
Untersuchungen zur elektroosmotischen Perfusion in kapillaren Festbetten
- 4 May 2001
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 40 (9) , 1684-1687
Electrokinetics in Fixed Beds: Experimental Demonstration of Electroosmotic Perfusion
- 4 May 2001
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 40 (9) , 1684-1687
Electrokinetics in Fixed Beds: Experimental Demonstration of Electroosmotic Perfusion
- 1 April 2001
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 19 (3-4) , 453-456
Using NMR displacement imaging to characterize electroosmotic flow in porous media
- 1 April 2001
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 19 (3-4) , 453-456
Using NMR displacement imaging to characterize electroosmotic flow in porous media
- 12 April 2000
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (10) , 2292-2301
Electroosmotic and Pressure-Driven Flow in Open and Packed Capillaries: Velocity Distributions and Fluid Dispersion
The flow field dynamics in open and packed segments of capillary columns has been studied by a direct motion encoding of the fluid molecules using pulsed magnetic field gradient nuclear magnetic resonance. This noninvasive method operates within a time window that allows a quantitative discrimination of electroosmotic against pressure-driven flow behavior. The inherent axial fluid flow field dispersion and characteristic length scales of either transport mode are addressed, and the results demonstrate a significant performance advantage of an electrokinetically driven mobile phase in both open-tubular and packed-bed geometries. In contrast to the parabolic velocity profile and its impact on axial dispersion characterizing laminar flow through an open cylindrical capillary, a pluglike velocity distribution of the electroosmotic flow field is revealed in capillary electrophoresis. Here, the variance of the radially averaged, axial displacement probability distributions is quantitatively explained by longitudinal molecular diffusion at the actual buffer temperature, while for Poiseuille flow, the preasymptotic regime to Taylor−Aris dispersion can be shown. Compared to creeping laminar flow through a packed bed, the increased efficiency observed in capillary electrochromatography is related to the superior characteristics of the electroosmotic flow profile over any length scale in the interstitial pore space and to the origin, spatial dimension, and hydrodynamics of the stagnant fluid on the support particles' external surface. Using the Knox equation to analyze the axial plate height data, an eddy dispersion term smaller by a factor of almost 2.5 than in capillary high-performance liquid chromatography is revealed for the electroosmotic flow field in the same column.
- 12 April 2000
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (10) , 2292-2301
Electroosmotic and Pressure-Driven Flow in Open and Packed Capillaries: Velocity Distributions and Fluid Dispersion
The flow field dynamics in open and packed segments of capillary columns has been studied by a direct motion encoding of the fluid molecules using pulsed magnetic field gradient nuclear magnetic resonance. This noninvasive method operates within a time window that allows a quantitative discrimination of electroosmotic against pressure-driven flow behavior. The inherent axial fluid flow field dispersion and characteristic length scales of either transport mode are addressed, and the results demonstrate a significant performance advantage of an electrokinetically driven mobile phase in both open-tubular and packed-bed geometries. In contrast to the parabolic velocity profile and its impact on axial dispersion characterizing laminar flow through an open cylindrical capillary, a pluglike velocity distribution of the electroosmotic flow field is revealed in capillary electrophoresis. Here, the variance of the radially averaged, axial displacement probability distributions is quantitatively explained by longitudinal molecular diffusion at the actual buffer temperature, while for Poiseuille flow, the preasymptotic regime to Taylor−Aris dispersion can be shown. Compared to creeping laminar flow through a packed bed, the increased efficiency observed in capillary electrochromatography is related to the superior characteristics of the electroosmotic flow profile over any length scale in the interstitial pore space and to the origin, spatial dimension, and hydrodynamics of the stagnant fluid on the support particles' external surface. Using the Knox equation to analyze the axial plate height data, an eddy dispersion term smaller by a factor of almost 2.5 than in capillary high-performance liquid chromatography is revealed for the electroosmotic flow field in the same column.
- 3 August 1998
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 37 (13-14) , 1882-1885
Direct Observation of Fluid Mass Transfer Resistance in Porous Media by NMR Spectroscopy
- 3 August 1998
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 37 (13-14) , 1882-1885
Direct Observation of Fluid Mass Transfer Resistance in Porous Media by NMR Spectroscopy