JWJ. Christian Winters

J. Christian Winters

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


J. Christian Winters has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Richard Vanlangendonck

    From the Ochsner Clinic Foundation, Department of Urology

    2 shared publications
  • Anthony J. Woodruff

    1 shared publication
  • Anthony R. Gauthier

    Department of Urology, Ochsner Clinic Foundation, New Orleans, Louisiana 70121, USA

    1 shared publication
  • Christopher C Roth

    Department of Urology, Ochsner Clinic Foundation

    1 shared publication
  • Christopher J. Chermansky

    Department of Urology, Louisiana State University Health Sciences Center, New Orleans, Louisiana, USA

    1 shared publication
  • David C. Owens

    Ochsner Clinic Foundation, Department of Urology, New Orleans, Louisiana 70121, USA

    1 shared publication

Latest Publications

  • Magnetic resonance imaging following interstim®: An institutional experience with imaging safety and patient satisfaction

    by Christopher J. Chermansky, Ryan M. Krlin, Thomas D. Holley, Howard H. Woo, J. Christian Winters

    Aims: We retrospectively assessed patient safety and satisfaction after magnetic resonance imaging (MRI) in patients with an InterStim® unit.Methods: The records of all patients implanted with InterStim® between 1998 and 2006 were reviewed. Nine of these patients underwent MRI following InterStim® implantation. The patients' neurologists requested the MRI exams for medical reasons. Both 0.6 Tesla (T) and 1.5 T machines were used. Patient safety, interference of implanted pulse generator (IPG) with radiological interpretation, and patient satisfaction were assessed in these patients.Results: The first patient in the series had IPG failure following MRI. For this patient, the voltage amplitude was set to zero, the IPG was turned off, and the IPG magnetic switch was left on. The patient underwent MRI uneventfully; however, the IPG did not function upon reprogramming. The IPG magnetic switch was turned off for the eight subsequent patients, all of whom underwent MRI safely. In addition, all of their IPGs functioned appropriately following reprogramming. Of the 15 MRIs performed, the lumbar spine was imaged in eight studies, the pelvis was imaged in one study, and the remaining examinations involved imaging the brain or cervical spine. Neither the IPG nor the sacral leads interfered with MRI interpretation. None of the eight patients perceived a change in perception or satisfaction following MRI.Conclusions: Although we don't advocate the routine use of MRI following InterStim® implantation, our experience suggests MRI may be feasible under controlled conditions and without adverse events. Neurourol. Urodynam. Neurourol. Urodynam. 30: 1486–1488, 2011.


  • Laparoscopic cecostomy tube placement in an Indiana pouch

    by Scott E. Delacroix Jr, Richard Vanlangendonck, J. Christian Winters

    A cecostomy tube is normally placed in an Indiana pouch for drainage and irrigation in the postoperative period. A clinical dilemma occurs when the cecostomy tube fails or is dislodged in the early postoperative period. We present the laparoscopic replacement of a cecostomy tube in the immediate postoperative period.

  • Reply by the Authors

    by Anthony J. Woodruff, J. Christian Winters, Emily E. Cole, Roger R. Dmochowski, Harriette M. Scarpero, Edwin N. Beckman

    • 1 January 2008
      • Vol. 8  (4) , 208-12

    Breast cancer metastatic to the urinary bladder.

    by Jennifer Ramsey, Edwin N Beckman, J Christian Winters

    Breast cancer is common and has the potential to spread to multiple organs. This article describes metastasis to the urinary bladder. In most instances, breast cancer metastatic to the bladder is associated with other pelvic organ metastasis. In patients with known metastatic breast cancer, bladder screening is not warranted. However, if lower urinary tract symptoms persist, an evaluation of the bladder should be considered to rule out metastatic involvement.


  • The use of synthetic mesh in female pelvic reconstructive surgery

    by J. Christian Winters, Mary P. Fitzgerald, Matthew D. Barber


  • InteXen tissue processing and laboratory study

    by J. Christian Winters

    The goal of this manuscript is to discuss the utilization of InteXen graft material, which is a natural, biocompatible matrix. There is unfortunately little data concerning this material; so, many of the concepts introduced in this manuscript are theoretical. We will discuss the rationale behind using InteXen as the biologic material of choice.


    • 1 January 2006
      • Vol. 6  (2) , 54-8

    Insertion of artificial urinary sphincter with preservation of bulbospongiosus muscle in patients at risk for sphincter erosion: an assessment of patient satisfaction.

    by Christopher C Roth, J Christian Winters

    To evaluate the safety and patient satisfaction following artificial urinary sphincter (AUS) placement with preservation of the bulbospongiosus muscle in patients at risk for erosion. The records of 67 patients who underwent AUS placement between the dates of 1997-2004 were reviewed. Patients were identified as being at risk for erosion if they had radiation therapy or previous erosion of an artificial sphincter. These patients underwent sphincter implantation emphasizing preservation of the bulbospongiosus muscle complex. Patients completed a phone interview and also returned an anonymous questionnaire containing the UDI-6, IIQ-7, PGI-I and a 10 point Likert scale to assess satisfaction. 21 men were identified as high risk for erosion. Average daily pad usage preoperatively was 6.4. No urethral injuries or intraoperative complications occurred. Cuff size ranged from 4.0 to 5.0. Three revisions were necessary to downsize the cuff. At a mean follow-up of 35.8 months, 15/21 participated in the surveys. Two-thirds considered themselves "cured" or "greatly improved" following sphincter placement. The average daily pad usage decreased to 3.1. On a scale of 1-10, the average self-grading of satisfaction was 8. None of the patients felt the surgery was difficult to undergo, and all but 3 would repeat the procedure again. No patients developed erosion or infection of the device. AUS placement can be safely done in patients at high risk for erosion by preserving the bulbospongiosus muscle complex. Long-term results are favorable with two-thirds of this difficult population highly satisfied with the result.


  • Open Access

    SUFU 2006 introduction

    by Chris Winters

  • Is there still a place for the pubovaginal sling at the bladder neck in the era of the midurethral sling?

    by Woodie J. Wilson, J. Christian Winters

    Perhaps the most significant advance in the modern-day surgical management of stress urinary incontinence is the introduction of the tension-free midurethral sling procedures. Based on a theory of anatomy and function, which emphasizes the importance of the midurethra in maintaining continence during stress, these minimally invasive procedures are being used widely in the surgical treatment of stress urinary incontinence. As surgeons continue to experience excellent early results, a major concern is defining the role of the traditional pubovaginal sling placed at the bladder neck. In addition to the obvious indications to consider a more traditional sling procedure (markedly atrophic vaginal wall or situations that may promote sling erosion), are there other clinical scenarios in which there still is a role for the traditional pubovaginal sling? Several clinical conditions that warrant consideration of a traditional sling procedure are presented in this review. Based on the mechanism of action and clinical data demonstrating decreased efficacy of midurethral sling procedures, we propose that a traditional pubovaginal sling be considered in the following clinical conditions: lack of urethral mobility, mixed urinary incontinence, concomitant urethral reconstruction, and after a failed sling procedure. In the absence of randomized control trials, we present evidence that makes a case for consideration of the traditional sling procedure in these complex clinical conditions.