  • Influence of nuclear interactions in body tissues on tumor dose in carbon‐ion radiotherapy

    by T. Inaniwa, N. Kanematsu, H. Tsuji, T. Kamada

    Purpose: In carbon‐ion radiotherapy treatment planning, the planar integrated dose (PID) measured in water is applied to the patient dose calculation with density scaling using the stopping power ratio. Since body tissues are chemically different from water, this dose calculation can be subject to errors, particularly due to differences in inelastic nuclear interactions. In recent studies, the authors proposed and validated a PID correction method for these errors. In the present study, the authors used this correction method to assess the influence of these nuclear interactions in body tissues on tumor dose in various clinical cases.Methods: Using 10–20 cases each of prostate, head and neck (HN), bone and soft tissue (BS), lung, liver, pancreas, and uterine neoplasms, the authors first used treatment plans for carbon‐ion radiotherapy without nuclear interaction correction to derive uncorrected dose distributions. The authors then compared these distributions with recalculated distributions using the nuclear interaction correction (corrected dose distributions).Results: Median (25%/75% quartiles) differences between the target mean uncorrected doses and corrected doses were 0.2% (0.1%/0.2%), 0.0% (0.0%/0.0%), −0.3% (−0.4%/−0.2%), −0.1% (−0.2%/−0.1%), −0.1% (−0.2%/0.0%), −0.4% (−0.5%/−0.1%), and −0.3% (−0.4%/0.0%) for the prostate, HN, BS, lung, liver, pancreas, and uterine cases, respectively. The largest difference of −1.6% in target mean and −2.5% at maximum were observed in a uterine case.Conclusions: For most clinical cases, dose calculation errors due to the water nonequivalence of the tissues in nuclear interactions would be marginal compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response. In some extreme cases, however, these errors can be substantial. Accordingly, this correction method should be routinely applied to treatment planning in clinical practice.


  • A dose calculation algorithm with correction for proton-nucleus interactions in non-water materials for proton radiotherapy treatment planning

    by T Inaniwa, N Kanematsu, S Sato, R Kohno

    In treatment planning for proton radiotherapy, the dose measured in water is applied to the patient dose calculation with density scaling by stopping power ratio . Since the body tissues are chemically different from water, this approximation may cause dose calculation errors, especially due to differences in nuclear interactions. We proposed and validated an algorithm for correcting these errors. The dose in water is decomposed into three constituents according to the physical interactions of protons in water: the dose from primary protons continuously slowing down by electromagnetic interactions, the dose from protons scattered by elastic and/or inelastic interactions, and the dose resulting from nonelastic interactions. The proportions of the three dose constituents differ between body tissues and water. We determine correction factors for the proportion of dose constituents with Monte Carlo simulations in various standard body tissues, and formulated them as functions of their for patient dose calculation. The influence of nuclear interactions on dose was assessed by comparing the Monte Carlo simulated dose and the uncorrected dose in common phantom materials. The influence around the Bragg peak amounted to −6% for polytetrafluoroethylene and 0.3% for polyethylene. The validity of the correction method was confirmed by comparing the simulated and corrected doses in the materials. The deviation was below 0.8% for all materials. The accuracy of the correction factors derived with Monte Carlo simulations was separately verified through irradiation experiments with a 235 MeV proton beam using common phantom materials. The corrected doses agreed with the measurements within 0.4% for all materials except graphite. The influence on tumor dose was assessed in a prostate case. The dose reduction in the tumor was below 0.5%. Our results verify that this algorithm is practical and accurate for proton radiotherapy treatment planning, and will also be useful in rapidly determining fluence correction factors for non-water phantom dosimetry.


  • Variation in patient position and impact on carbon-ion scanning beam distribution during prostate treatment

    by S Mori, T Inaniwa, K Miki, K Tanimoto, M Tajiri, D Kuroiwa, M Nakao, Y Shiraishi, K Shibayama, H Tsuji

    We assessed the impact of changes in patient position on carbon-ion scanning beam distribution during treatment for prostate cancer. 68 patients were selected. Carbon-ion scanning dose was calculated. Two different planning target volumes (PTVs) were defined: PTV1 was the clinical target volume plus a set-up margin for the anterior/lateral sides and posterior side, while PTV2 was the same as PTV1 minus the posterior side. Total prescribed doses of 34.4 Gy [relative biological effectiveness (RBE)] and 17.2 Gy (RBE) were given to PTV1 and PTV2, respectively. To estimate the influence of geometric variations on dose distribution, the dose was recalculated on the rigidly shifted single planning CT based on two dimensional–three dimensional rigid registration of the orthogonal radiographs before and after treatment for the fraction of maximum positional changes. Intrafractional patient positional change values averaged over all patients throughout the treatment course were less than the target registration error = 2.00 mm and angular error = 1.27°. However, these maximum positional errors did not occur in all 12 treatment fractions. Even though large positional changes occurred during irradiation in all treatment fractions, lowest dose encompassing 95% of the target (D95)-PTV1 was >98% of the prescribed dose. Intrafractional patient positional changes occurred during treatment beam irradiation and degraded carbon-ion beam dose distribution. Our evaluation did not consider non-rigid deformations, however, dose distribution was still within clinically acceptable levels. Inter- and intrafractional changes did not affect carbon-ion beam prostate treatment accuracy.


  • Open Access

    Carbon-ion scanning lung treatment planning with respiratory-gated phase-controlled rescanning: simulation study using 4-dimensional CT data

    by Wataru Takahashi, Shinichiro Mori, Mio Nakajima, Naoyoshi Yamamoto, Taku Inaniwa, Takuji Furukawa, Toshiyuki Shirai, Koji Noda, Keiichi Nakagawa, Tadashi Kamada

    To moving lung tumors, we applied a respiratory-gated strategy to carbon-ion pencil beam scanning with multiple phase-controlled rescanning (PCR). In this simulation study, we quantitatively evaluated dose distributions based on 4-dimensional CT (4DCT) treatment planning. Volumetric 4DCTs were acquired for 14 patients with lung tumors. Gross tumor volume, clinical target volume (CTV) and organs at risk (OARs) were delineated. Field-specific target volumes (FTVs) were calculated, and 48Gy(RBE) in a single fraction was prescribed to the FTVs delivered from four beam angles. The dose assessment metrics were quantified by changing the number of PCR and the results for the ungated and gated scenarios were then compared. For the ungated strategy, the mean dose delivered to 95% of the volume of the CTV (CTV-D95) was in average 45.3 ± 0.9 Gy(RBE) even with a single rescanning (1 × PCR). Using 4 × PCR or more achieved adequate target coverage (CTV-D95 = 46.6 ± 0.3 Gy(RBE) for ungated 4 × PCR) and excellent dose homogeneity (homogeneity index =1.0 ± 0.2% for ungated 4 × PCR). Applying respiratory gating, percentage of lung receiving at least 20 Gy(RBE) (lung-V20) and heart maximal dose, averaged over all patients, significantly decreased by 12% (p < 0.05) and 13% (p < 0.05), respectively. Four or more PCR during PBS-CIRT improved dose conformation to moving lung tumors without gating. The use of a respiratory-gated strategy in combination with PCR reduced excessive doses to OARs.


  • Effects of Dose-Delivery Time Structure on Biological Effectiveness for Therapeutic Carbon-Ion Beams Evaluated with Microdosimetric Kinetic Model

    by Taku Inaniwa, Masao Suzuki, Takuji Furukawa, Yuki Kase, Nobuyuki Kanematsu, Toshiyuki Shirai, Roland B. Hawkins

    Treatment plans of carbon-ion radiotherapy have been made on the assumption that the beams are delivered instantaneously irrespective to the dose delivery time as well as the interruption time. The advanced therapeutic techniques such as a hypofractionation and a respiratory gating usually require more time to deliver a fractioned dose than conventional techniques. The purpose of this study was to investigate the effects of dose-delivery time structure on biological effectiveness in carbon-ion radiotherapy. The rate equations defined in the microdosimetric kinetic model (MKM) for primary lesions caused in the DNA were reanalyzed and applied to continuous or interrupted irradiation with therapeutic carbon-ion beams. The rate constants characterizing the time of the primary nonlethal lesions to repair or to convert to lethal lesion were experimentally determined for human salivary gland (HSG) tumor cells. Treatment plans were made for a patient case on the assumption that the beam is delivered instantaneously. The RBE weighted absorbed doses of 2.65, 3.45 and 6.86 Gy (RBE) was prescribed to the target. These plans were recalculated by varying the dose delivery time and the interruption time ranging from 1-60 min based on the MKM with the determined parameters. The sum of rate constants for nonlethal lesion to repair a and to convert to lethal lesion c, (a + c), is 2.19 ± 0.40 h⁻¹. The biological effectiveness in the target decreases with the dose delivery time T in continuous irradiation compared to the planned one due to the repair of nonlethal lesions during the irradiation. The biological effectiveness in terms of equivalent acute dose decreases to 99.7% and 96.4% for T = 3 and 60 min in 2.65 Gy (RBE), 99.5% and 94.3% in 4.35 Gy (RBE), and 99.4% and 91.7% in 6.86 Gy (RBE), respectively. For all the cases, the decrease of biological effectiveness is larger at the proximal side with low-LET than the distal side with high-LET. Similar reductions of biological effectiveness with comparable amounts are observed in the interrupted irradiations with prolonged interruption time τ. For the fraction time, i.e., T and/or τ, shorter than 3 min, the decrease of the biological effectiveness with respect to the planned one is less than 1.0%. However, if the fraction time prolongs to 30 min or longer, the biological effectiveness is significantly influenced in carbon-ion radiotherapy, especially with high-prescribed doses. These effects, if confirmed by clinical studies, should be considered in designing the carbon-ion treatment planning.


  • Evaluation of hybrid depth scanning for carbon‐ion radiotherapy

    by Taku Inaniwa, Takuji Furukawa, Nobuyuki Kanematsu, Shinichiro Mori, Kota Mizushima, Shinji Sato, Toshiyuki Toshito, Toshiyuki Shirai, Koji Noda

    Purpose:: In radiotherapy with a scanned carbon‐ion beam, its Bragg peak is shifted along the depth direction either by inserting the range shifter plates or by changing the beam‐extraction energy of a synchrotron. In the former technique (range shifter scanning: RS), the range shifter plates broaden the beam size and produce secondary fragments through nuclear reactions. In the latter technique (active‐energy scanning: ES), it may take several seconds to change the beam energy depending on the synchrotron operation cycle, leading to a long treatment time. The authors propose a hybrid depth scan technique (hybrid scanning: HS), where several beam energies are used in conjunction with the range shifter plates for finer range shift. In this study, HS is evaluated from the viewpoints of dose distribution and treatment time.Methods:: Assuming realistic accelerator and beam‐delivery systems, the authors performed computer simulations usingGEANT4Monte Carlo code for beam modeling and a treatment planning system to evaluate HS. Three target volumes with the same dimensions of 60 × 60 × 60 mm3were generated at depths of 45, 85, and 125 mm in water phantom, and uniform clinical dose was planned for these targets. The sizes of lateral dose falloff and the peak to plateau ratio defined as the ratio of the clinical dose averaged over the target to the clinical dose at the entrance as well as the treatment time were compared among the three depth scan techniques.Results:: The sizes of lateral dose falloffs at the center of SOBP are 11.4, 8.5, and 5.9 mm for the three targets in RS, while they are 5.7, 4.8, and 4.6 mm in ES and 6.6, 5.7, and 5.0 mm in HS, respectively. The peak to plateau ratios are 1.39, 1.96, and 2.15 in RS, while they are 1.48, 2.04, and 2.19 in ES and 1.47, 2.03, and 2.18 in HS, respectively. The treatment times are 128.7, 128.6, and 128.6 s in ES, while they are 61.2, 54.6, and 47.8 s in RS and 43.2, 44.1, and 44.7 s in HS, respectively. The multiple scattering and the nuclear reaction by range shifter degraded the beam qualities such as lateral dose falloff and peak to plateau ratio, which was especially pronounced for the shallow target in RS. The depth scan timing was limited by accelerator cycle in ES. That increased the treatment time by a few times.Conclusions:: This study revealed that HS can provide dose distributions with steeper lateral dose falloffs and higher peak to plateau ratio comparing to RS and comparable to ES. In addition, the treatment time can be considerably reduced in HS compared to ES.


  • A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage

    by Taku Inaniwa, Nobuyuki Kanematsu, Takuji Furukawa, Azusa Hasegawa

    Intensity modulated proton therapy (IMPT) offers the possibility of generating excellent target coverage while sparing the neighbouring organs at risk. However, treatment plans optimized for IMPT may be very sensitive to range and setup uncertainties. We developed a method to deal with these uncertainties in the dose optimization. This method aims at two objectives: one for maintaining the dose coverage within the target, and the other for preventing undesired exposure to organs at risk. The former objective was achieved by the algorithm described in our previous paper to suppress the in-field dose gradient within the target. In this study, the latter objective was achieved by a novel algorithm in which we suppressed pencil beams with high risk to deliver undesired doses to organs at risk under conditions where range and setup uncertainties occur. We defined the risk index that quantifies the likelihood of each pencil beam delivering high doses to organs at risk, and introduced it into the objective function of dose optimizations. In order to test the algorithm's performance, this method was applied to an RTOG benchmark phantom geometry and to a cervical chordoma case. These simulations demonstrated that our method provides IMPT plans that are more robust against range and setup errors compared to conventional IMPT plans. Compared to the conventional IMPT plan, the optimization time for the robust plan increased by a factor of only 3, from 4 to 11 min.


  • Optimization algorithm for overlapping-field plans of scanned ion beam therapy with reduced sensitivity to range and setup uncertainties

    by Taku Inaniwa, Nobuyuki Kanematsu, Takuji Furukawa, Koji Noda

    A 'patch-field' strategy is often used for tumors with large volumes exceeding the available field size in passive irradiations with ion beams. Range and setup errors can cause hot and cold spots at the field junction within the target. Such errors will also displace the field to miss the target periphery. With scanned ion beams with fluence modulation, the two junctional fields can be overlapped rather than patched, which may potentially reduce the sensitivity to these uncertainties. In this study, we have developed such a robust optimization algorithm. This algorithm is composed of the following two steps: (1) expanding the target volume with margins against the uncertainties, and (2) solving the inverse problem where the terms suppressing the dose gradient of individual fields are added into the objective function. The validity of this algorithm is demonstrated through simulation studies for two extreme cases of two fields with unidirectional and opposing geometries and for a prostate-cancer case. With the proposed algorithm, we can obtain a more robust plan with minimized influence of range and setup uncertainties than the conventional plan. Compared to conventional optimization, the calculation time for the robust optimization increased by a factor of approximately 3.


  • Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model

    by Taku Inaniwa, Takuji Furukawa, Yuki Kase, Naruhiro Matsufuji, Toshiyuki Toshito, Yoshitaka Matsumoto, Yoshiya Furusawa, Koji Noda

    We describe a method to calculate the relative biological effectiveness in mixed radiation fields of therapeutic ion beams based on the modified microdosimetric kinetic model (modified MKM). In addition, we show the procedure for integrating the modified MKM into a treatment planning system for a scanned carbon beam. With this procedure, the model is fully integrated into our research version of the treatment planning system. To account for the change in radiosensitivity of a cell line, we measured one of the three MKM parameters from a single survival curve of the current cells and used the parameter in biological optimization. Irradiation of human salivary gland tumor cells was performed with a scanned carbon beam in the Heavy Ion Medical Accelerator in Chiba (HIMAC), and we then compared the measured depth-survival curve with the modified MKM predicted survival curve. Good agreement between the two curves proves that the proposed method is a candidate for calculating the biological effects in treatment planning for ion irradiation.