Noboru Hosono
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Noboru Hosono has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
H. Sakaura
Osaka University Graduate School of Medicine
1 shared publicationH. Yoshikawa
Osaka University Graduate School of Medicine
1 shared publicationHideki Yoshikawa
1 shared publicationHideki Yoshikawa
1 shared publicationHironobu Sakaura
1 shared publicationKazuo Yonenobu
1 shared publication
Latest Publications
- 18 March 2006
- Published by Springer Nature in European Spine Journal
- Vol. 15 (9) , 1375-1379
C3-6 laminoplasty takes over C3-7 laminoplasty with significantly lower incidence of axial neck pain
Five-lamina (C3-7) procedure is the most popular cervical laminoplasty and there have been no studies on the most appropriate number of laminae to be opened. We prospectively reduced the range of laminoplasty from C3-7 to C3-6 in 2002 and compared the outcome of C3-6 laminoplasty (n=37) to that of C3-7 laminoplasty (n=28). In both groups, neurological gain was satisfactory, radiographic changes were minimal, and postoperative MRI indicated sufficient expansion of the dura and the spinal cord. Average operating period was significantly shorter, and length of the operative wound was significantly less in the C3-6 group than in the C3-7 group. Postoperative axial neck pain was significantly rarer after C3-6 laminoplasty than after C3-7 laminoplasty (5.4% vs. 29%, P=0.015). Due to its simplicity and various benefits, C3-6 laminoplasty is a promising alternative to conventional C3-7 laminoplasty for treatment of multisegmental compression myelopathy.
- 18 March 2006
- Published by Springer Nature in European Spine Journal
- Vol. 15 (9) , 1375-1379
C3-6 laminoplasty takes over C3-7 laminoplasty with significantly lower incidence of axial neck pain
Five-lamina (C3-7) procedure is the most popular cervical laminoplasty and there have been no studies on the most appropriate number of laminae to be opened. We prospectively reduced the range of laminoplasty from C3-7 to C3-6 in 2002 and compared the outcome of C3-6 laminoplasty (n=37) to that of C3-7 laminoplasty (n=28). In both groups, neurological gain was satisfactory, radiographic changes were minimal, and postoperative MRI indicated sufficient expansion of the dura and the spinal cord. Average operating period was significantly shorter, and length of the operative wound was significantly less in the C3-6 group than in the C3-7 group. Postoperative axial neck pain was significantly rarer after C3-6 laminoplasty than after C3-7 laminoplasty (5.4% vs. 29%, P=0.015). Due to its simplicity and various benefits, C3-6 laminoplasty is a promising alternative to conventional C3-7 laminoplasty for treatment of multisegmental compression myelopathy.
- 1 July 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 3 (1) , 29-33
En bloc laminoplasty without dissection of paraspinal muscles
Object. Although conducting cervical laminoplasty in patients with multisegmental cord compression provides good neurological results, it is not without shortcomings, including C-5 palsy, axial neck pain, and undesirable radiologically detectable changes. Postoperative kyphosis and segmental instability can cause neurological problems and are believed mainly to result from neck muscle disruption. The authors developed a new laminoplasty technique, with the aim of preserving optimal muscle function. Methods. The present technique is a modification of unilateral open-door laminoplasty. By using an ultrasonic osteotome in small gaps of muscle bellies, a gutter is made without disrupting muscles, spinous processes, or their connections on the hinged side. Ceramic spacers are then positioned between elevated laminae and lateral masses at C-3, C-5, and C-7 on the opened side, which is exposed in a conventional manner. This new procedure was used to treat 37 consecutive patients with compression myelopathy. Postoperative computerized tomography (CT) scanning revealed a significant difference in a cross-sectional area of muscles between the hinged and opened side. The mean follow-up period was 40.2 months (range 24–54 months). Changes in alignment were observed in only one patient, and vertebral slippage developed in two. Performed at regular intervals, CT scanning demonstrated that the elevated laminae remained in situ throughout the study period. Conclusions. In using the present unilateral open-door laminoplasty technique, deep extensor muscles are left intact along with their junctions to spinous processes on the hinged side. Radiologically documented changes were minimal because the preserved muscles functioned normally immediately after the operation.
- 1 July 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 3 (1) , 29-33
En bloc laminoplasty without dissection of paraspinal muscles
Object. Although conducting cervical laminoplasty in patients with multisegmental cord compression provides good neurological results, it is not without shortcomings, including C-5 palsy, axial neck pain, and undesirable radiologically detectable changes. Postoperative kyphosis and segmental instability can cause neurological problems and are believed mainly to result from neck muscle disruption. The authors developed a new laminoplasty technique, with the aim of preserving optimal muscle function. Methods. The present technique is a modification of unilateral open-door laminoplasty. By using an ultrasonic osteotome in small gaps of muscle bellies, a gutter is made without disrupting muscles, spinous processes, or their connections on the hinged side. Ceramic spacers are then positioned between elevated laminae and lateral masses at C-3, C-5, and C-7 on the opened side, which is exposed in a conventional manner. This new procedure was used to treat 37 consecutive patients with compression myelopathy. Postoperative computerized tomography (CT) scanning revealed a significant difference in a cross-sectional area of muscles between the hinged and opened side. The mean follow-up period was 40.2 months (range 24–54 months). Changes in alignment were observed in only one patient, and vertebral slippage developed in two. Performed at regular intervals, CT scanning demonstrated that the elevated laminae remained in situ throughout the study period. Conclusions. In using the present unilateral open-door laminoplasty technique, deep extensor muscles are left intact along with their junctions to spinous processes on the hinged side. Radiologically documented changes were minimal because the preserved muscles functioned normally immediately after the operation.
- 15 July 2003
- Vol. 28 (14) , 1528-33
Mechanical stress-induced apoptosis of endplate chondrocytes in organ-cultured mouse intervertebral discs: an ex vivo study.
Various amounts of static mechanical load were applied to mouse intervertebral discs in organ cultures. The apoptosis then was examined using nick end labeling. Two mitogen-activated protein kinase (MAPK) inhibitors were added to the medium. To establish an experimental model for detecting factors regulating chondrocyte apoptosis induced by mechanical stress, and to determine the role of MAPK and p38 in the stress-induced apoptotic pathway of endplate chondrocytes. The cause of degenerative change in the cartilaginous endplate (CEP) remains unclear. The authors' previous findings using a mouse model suggested that apoptosis in the cartilaginous endplate may play a role in intervertebral disc degeneration, and that mechanical stress may induce apoptosis. If apoptosis of endplate chondrocytes is involved in the cascade of intervertebral disc degeneration, then how apoptosis is induced by mechanical stress should be important in preventing disc degeneration. However, the mechanism of apoptosis induced by mechanical stress remains unclear. Mouse coccygeal discs were harvested and organ cultured. Various static compression loads (0, 0.2, 0.4, 0.8, and 1.0 MPa) were applied on intervertebral discs placed in culture bottles for 24 hours. Paraffin-embedded sections of the harvested discs were stained using Safranin-O and the nick end labeling procedure. The apoptotic cells were counted in the cartilaginous endplate and junctional anulus fibrosus of each intervertebral disc. In addition, U0126 (MAPK inhibitor) and SB202190 (p38 inhibitor) were added to the culture medium to determine their regulatory roles in the apoptosis of endplate chondrocytes induced by mechanical load. Histologically, loaded discs became bulged, and the disc space became narrow. Apoptosis was absent in discs without load, but was particularly noticeable in loaded discs (load weight, 1.0 MPa). The number of apoptotic cells increased depending on the weight of the load. The two MAPK inhibitors significantly increased the number of apoptotic cells. Chondrocyte apoptosis was induced using a static mechanical load especially in the cartilaginous endplate in an organ culture. Apoptosis occurred similarly to previous findings using an in vivo model. This culture system thus reflected the apoptosis demonstrated in vivo. Because biologically active reagents such as MAPK inhibitors can be simply added to culture media, this system may be a useful method for detecting factors that influence apoptosis induced by mechanical stress. Both MAPK inhibitors increased the occurrence of apoptosis. This suggests that these two MAPKs can counteract the apoptotic pathway induced by mechanical stress.
- 15 July 2003
- Vol. 28 (14) , 1528-33
Mechanical stress-induced apoptosis of endplate chondrocytes in organ-cultured mouse intervertebral discs: an ex vivo study.
Various amounts of static mechanical load were applied to mouse intervertebral discs in organ cultures. The apoptosis then was examined using nick end labeling. Two mitogen-activated protein kinase (MAPK) inhibitors were added to the medium. To establish an experimental model for detecting factors regulating chondrocyte apoptosis induced by mechanical stress, and to determine the role of MAPK and p38 in the stress-induced apoptotic pathway of endplate chondrocytes. The cause of degenerative change in the cartilaginous endplate (CEP) remains unclear. The authors' previous findings using a mouse model suggested that apoptosis in the cartilaginous endplate may play a role in intervertebral disc degeneration, and that mechanical stress may induce apoptosis. If apoptosis of endplate chondrocytes is involved in the cascade of intervertebral disc degeneration, then how apoptosis is induced by mechanical stress should be important in preventing disc degeneration. However, the mechanism of apoptosis induced by mechanical stress remains unclear. Mouse coccygeal discs were harvested and organ cultured. Various static compression loads (0, 0.2, 0.4, 0.8, and 1.0 MPa) were applied on intervertebral discs placed in culture bottles for 24 hours. Paraffin-embedded sections of the harvested discs were stained using Safranin-O and the nick end labeling procedure. The apoptotic cells were counted in the cartilaginous endplate and junctional anulus fibrosus of each intervertebral disc. In addition, U0126 (MAPK inhibitor) and SB202190 (p38 inhibitor) were added to the culture medium to determine their regulatory roles in the apoptosis of endplate chondrocytes induced by mechanical load. Histologically, loaded discs became bulged, and the disc space became narrow. Apoptosis was absent in discs without load, but was particularly noticeable in loaded discs (load weight, 1.0 MPa). The number of apoptotic cells increased depending on the weight of the load. The two MAPK inhibitors significantly increased the number of apoptotic cells. Chondrocyte apoptosis was induced using a static mechanical load especially in the cartilaginous endplate in an organ culture. Apoptosis occurred similarly to previous findings using an in vivo model. This culture system thus reflected the apoptosis demonstrated in vivo. Because biologically active reagents such as MAPK inhibitors can be simply added to culture media, this system may be a useful method for detecting factors that influence apoptosis induced by mechanical stress. Both MAPK inhibitors increased the occurrence of apoptosis. This suggests that these two MAPKs can counteract the apoptotic pathway induced by mechanical stress.