Zongtao Ge
Zongtao Ge has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Mitsuo Takeda
Department of Information and Communication Engineering the University of Electro-Communications 1-5-1, Chofugaoka, Chofu, Tokyo 182-8585, Japan http://www.uec.ac.jp
3 shared publicationsFumio Kobayashi
Fujinon Corporation
2 shared publicationsHideo Kanda
Fujinon Corporation 1-324, Uetake, Saitama City, Saitama 330-8624, Japan http://www.fujinon.co.jp
1 shared publicationKazuhisa Arakawa
Fujinon Corporation 1-324, Uetake, Saitama City, Saitama 330-8624, Japan http://www.fujinon.co.jp
1 shared publicationMinoru Kurose
Fujinon Corporation 1-324, Uetake, Saitama City, Saitama 330-8624, Japan http://www.fujinon.co.jp
1 shared publicationShinichi Matsuda
Z. Ge, F. Kobayashi, and S. Matsuda are with the Corporate Research and Development Office, Fuji Photo Optical Company, Ltd., 1-324, Uetake, Omiya City, Saitama 330-8624, Japan.M. Takeda is with the Department of Information and Communication Engineering, University of Electro-Communications, 1-5-1, Chofugaoka, Chofu, Tokyo 182-8585, Japan
1 shared publication
Latest Publications
- Open Access
- 1 January 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (1) , 133-143
Precision interferometry for measuring wavefronts of multi-wavelength optical pickups.
A novel wavefront measurement interferometer is developed that enables the user to evaluate the wavefronts of multi-wavelength optical pickups. In this interferometer, instead of transparent pinholes used in Mach-Zehnder interferometers, reflection dot pinhole mirrors are used to generate reference wavefronts for different wavelengths which make the optical system very flexible and simple compared with those using transparent pinholes. The interferometer is designed to operate at wavelengths of 405 nm, 650 nm and 780 nm over an NA range of up to 0.95, which is very difficult to realize when transparent pinholes are used for generating reference wavefronts. The three-beam problem is solved and the optics of the interferometer is simplified by employing a software filter instead of using spatial filters in the optics of the interferometer. The instrument has an equal optical path length that enables the user to measure pickups with a very short coherence length. A new method by which asymmetric aberration components, such as astigmatic and coma aberrations, can be calibrated by rotating the measured lens with 90 and 180 degrees is proposed and the calibration results are verified by using a high precision reference point source. System accuracy is also evaluated by comparing with the measurement results obtained by commercial Fizeau type interferometer and a good agreement is achieved.
- 1 January 2008
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (1) , 133-143
Open AccessPrecision interferometry for measuring wavefronts of multi-wavelength optical pickups.
A novel wavefront measurement interferometer is developed that enables the user to evaluate the wavefronts of multi-wavelength optical pickups. In this interferometer, instead of transparent pinholes used in Mach-Zehnder interferometers, reflection dot pinhole mirrors are used to generate reference wavefronts for different wavelengths which make the optical system very flexible and simple compared with those using transparent pinholes. The interferometer is designed to operate at wavelengths of 405 nm, 650 nm and 780 nm over an NA range of up to 0.95, which is very difficult to realize when transparent pinholes are used for generating reference wavefronts. The three-beam problem is solved and the optics of the interferometer is simplified by employing a software filter instead of using spatial filters in the optics of the interferometer. The instrument has an equal optical path length that enables the user to measure pickups with a very short coherence length. A new method by which asymmetric aberration components, such as astigmatic and coma aberrations, can be calibrated by rotating the measured lens with 90 and 180 degrees is proposed and the calibration results are verified by using a high precision reference point source. System accuracy is also evaluated by comparing with the measurement results obtained by commercial Fizeau type interferometer and a good agreement is achieved.
- 10 August 2006
- Published by Optica Publishing Group in Applied Optics
- Vol. 45 (23) , 5832-5839
High-precision measurement of a fiber connector end face by use of a Mirau interferometer
What we believe to be a new instrument for measuring the end-face geometrical parameters of fiber connectors is described. In this apparatus, a Mirau-type interferometric objective is employed to measure a small area of the connector end face and generate an interferogram corresponding to the surface profile. Various new technologies are used to ensure excellent performance and high measurement repeatability. A multipoint method is proposed to adjust the inclination of the physical contact sample stage. The physical contact angle of the sample stage is adjusted directly on the instrument by use of a special tool whose angle is calibrated with the reversal method. Measurement results of important parameters of the fiber connector end face are compared with those inspected by a commercial profiler or with a standard sample. Optical insertion losses of connectors inspected by the developed system are also evaluated.
- 10 August 2006
- Published by Optica Publishing Group in Applied Optics
- Vol. 45 (23) , 5832-5839
High-precision measurement of a fiber connector end face by use of a Mirau interferometer
What we believe to be a new instrument for measuring the end-face geometrical parameters of fiber connectors is described. In this apparatus, a Mirau-type interferometric objective is employed to measure a small area of the connector end face and generate an interferogram corresponding to the surface profile. Various new technologies are used to ensure excellent performance and high measurement repeatability. A multipoint method is proposed to adjust the inclination of the physical contact sample stage. The physical contact angle of the sample stage is adjusted directly on the instrument by use of a special tool whose angle is calibrated with the reversal method. Measurement results of important parameters of the fiber connector end face are compared with those inspected by a commercial profiler or with a standard sample. Optical insertion losses of connectors inspected by the developed system are also evaluated.
- 1 December 2003
- Published by Optica Publishing Group in Applied Optics
- Vol. 42 (34) , 6859-6868
High-resolution two-dimensional angle measurement technique based on fringe analysis
A novel angle-measurement technique based on fringe analysis for phase-measuring profilometry is proposed. A two-dimensional (2-D) angle between two mirror surfaces is determined by least-squares fitting of a plane to the 2-D distribution of the phase difference introduced by the 2-D tilt angle. To evaluate the performance of the proposed technique, numerical simulations that use the Fourier-transform technique and the phase-shift technique for fringe analysis were performed, and the results are compared. A 2-D angle-measurement interferometer based on a Mirau interference microscope was developed that demonstrated the validity of the proposed principle. It is shown by simulation and experiment that the proposed 2-D angle-measurement technique can achieve both a wide measurement range and a high angular resolution simultaneously.
- 1 December 2003
- Published by Optica Publishing Group in Applied Optics
- Vol. 42 (34) , 6859-6868
High-resolution two-dimensional angle measurement technique based on fringe analysis
A novel angle-measurement technique based on fringe analysis for phase-measuring profilometry is proposed. A two-dimensional (2-D) angle between two mirror surfaces is determined by least-squares fitting of a plane to the 2-D distribution of the phase difference introduced by the 2-D tilt angle. To evaluate the performance of the proposed technique, numerical simulations that use the Fourier-transform technique and the phase-shift technique for fringe analysis were performed, and the results are compared. A 2-D angle-measurement interferometer based on a Mirau interference microscope was developed that demonstrated the validity of the proposed principle. It is shown by simulation and experiment that the proposed 2-D angle-measurement technique can achieve both a wide measurement range and a high angular resolution simultaneously.
- 1 April 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (10) , 1649-1657
Coordinate-transform technique for closed-fringe analysis by the Fourier-transform method
A coordinate-transform technique is proposed that enables the Fourier-transform method to analyze an interferogram that includes a closed-fringe pattern. First, the closed-fringe pattern is converted to an open-fringe pattern by transformation of the Cartesian coordinate system to a polar coordinate system. Then the phase distribution for the open-fringe interferogram is determined by the conventional Fourier-transform method. The phase distribution for the original closed-fringe pattern is obtained by inverse coordinate transformation from the polar coordinate system back to the Cartesian coordinate system. Computer simulation and experiments were performed for a closed-fringe pattern generated by interference of a spherical wave with a reference plane wave, and results are presented that demonstrate the validity of the proposed technique.
- 1 April 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (10) , 1649-1657
Coordinate-transform technique for closed-fringe analysis by the Fourier-transform method
A coordinate-transform technique is proposed that enables the Fourier-transform method to analyze an interferogram that includes a closed-fringe pattern. First, the closed-fringe pattern is converted to an open-fringe pattern by transformation of the Cartesian coordinate system to a polar coordinate system. Then the phase distribution for the open-fringe interferogram is determined by the conventional Fourier-transform method. The phase distribution for the original closed-fringe pattern is obtained by inverse coordinate transformation from the polar coordinate system back to the Cartesian coordinate system. Computer simulation and experiments were performed for a closed-fringe pattern generated by interference of a spherical wave with a reference plane wave, and results are presented that demonstrate the validity of the proposed technique.