Jörg Enderlein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jörg Enderlein has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Claus B. Müller
III. Institute of Physics, Georg August University, 37077 Göttingen, Germany
2 shared publicationsAnastasia Loman
III. Institute of Physics, Georg August University,37077 Göttingen,Germany
1 shared publicationG. Iyer
Departments of aChemistry and Biochemistry and
1 shared publication- Ingo Gregor
Third Institute of Physics—Biophysics, Georg August University, Göttingen, Germany
1 shared publication Jana Schmitzová
Max Planck Institute for Biophysical Chemistry, D-37077 Göttingen, Germany
1 shared publicationJulia Dannenberg
Max Planck Institute for Biophysical Chemistry, D-37077 Göttingen, Germany
1 shared publication
Latest Publications
- 14 March 2016
- Published by Walter de Gruyter GmbH
Fluorescence Correlation Spectroscopy
We present an overview on the applicability of fluorescence correlation spectroscopy (FCS) for the accurate determination of translational diffusion coefficients and thus, via the Stokes–Einstein relation, of molecular size. We consider several of the most common sources of optical aberrations and their impact on the outcome of conventional FCS measurements. We describe also a new variant of FCS, dual-focus FCS, which is robust against most of the considered aberrations, and we report reference values of diffusion coefficients for several fluorescent dyes across the visible spectrum.
- 14 March 2016
- Published by Walter de Gruyter GmbH
Fluorescence Correlation Spectroscopy
We present an overview on the applicability of fluorescence correlation spectroscopy (FCS) for the accurate determination of translational diffusion coefficients and thus, via the Stokes–Einstein relation, of molecular size. We consider several of the most common sources of optical aberrations and their impact on the outcome of conventional FCS measurements. We describe also a new variant of FCS, dual-focus FCS, which is robust against most of the considered aberrations, and we report reference values of diffusion coefficients for several fluorescent dyes across the visible spectrum.
- Open Access
- 25 April 2012
- Published by Cold Spring Harbor Laboratory in RNA
- Vol. 18 (6) , 1244-1256
Prp2-mediated protein rearrangements at the catalytic core of the spliceosome as revealed by dcFCCS
The compositional and conformational changes during catalytic activation of the spliceosome promoted by the DEAH box ATPase Prp2 are only poorly understood. Here, we show by dual-color fluorescence cross-correlation spectroscopy (dcFCCS) that the binding affinity of several proteins is significantly changed during the Prp2-mediated transition of precatalytic Bact spliceosomes to catalytically activated B* spliceosomes from Saccharomyces cerevisiae. During this step, several proteins, including the zinc-finger protein Cwc24, are quantitatively displaced from the B* complex. Consistent with this, we show that Cwc24 is required for step 1 but not for catalysis per se. The U2-associated SF3a and SF3b proteins Prp11 and Cus1 remain bound to the B* spliceosome under near-physiological conditions, but their binding is reduced at high salt. Conversely, high-affinity binding sites are created for Yju2 and Cwc25 during catalytic activation, consistent with their requirement for step 1 catalysis. Our results suggest high cooperativity of multiple Prp2-mediated structural rearrangements at the spliceosome's catalytic core. Moreover, dcFCCS represents a powerful tool ideally suited to study quantitatively spliceosomal protein dynamics in equilibrium.
- 25 April 2012
- Published by Cold Spring Harbor Laboratory in RNA
- Vol. 18 (6) , 1244-1256
Open AccessPrp2-mediated protein rearrangements at the catalytic core of the spliceosome as revealed by dcFCCS
The compositional and conformational changes during catalytic activation of the spliceosome promoted by the DEAH box ATPase Prp2 are only poorly understood. Here, we show by dual-color fluorescence cross-correlation spectroscopy (dcFCCS) that the binding affinity of several proteins is significantly changed during the Prp2-mediated transition of precatalytic Bact spliceosomes to catalytically activated B* spliceosomes from Saccharomyces cerevisiae. During this step, several proteins, including the zinc-finger protein Cwc24, are quantitatively displaced from the B* complex. Consistent with this, we show that Cwc24 is required for step 1 but not for catalysis per se. The U2-associated SF3a and SF3b proteins Prp11 and Cus1 remain bound to the B* spliceosome under near-physiological conditions, but their binding is reduced at high salt. Conversely, high-affinity binding sites are created for Yju2 and Cwc25 during catalytic activation, consistent with their requirement for step 1 catalysis. Our results suggest high cooperativity of multiple Prp2-mediated structural rearrangements at the spliceosome's catalytic core. Moreover, dcFCCS represents a powerful tool ideally suited to study quantitatively spliceosomal protein dynamics in equilibrium.
- Top Cited Papers
- 10 May 2010
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 104 (19) , 198101
Image Scanning Microscopy
A new microscopy technique is introduced, image scanning microscopy (ISM), which combines conventional confocal-laser scanning microscopy with fast wide-field CCD detection. The technique allows for doubling the lateral optical resolution in fluorescence imaging. The physical principle behind ISM is similar to structured illumination microscopy, by combining the resolving power of confocal-laser scanning microscopy with that of a wide-field imaging microscopy. This Letter describes the theoretical foundation and experimental realization of ISM.
- 10 May 2010
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 104 (19) , 198101
Top Cited PapersImage Scanning Microscopy
A new microscopy technique is introduced, image scanning microscopy (ISM), which combines conventional confocal-laser scanning microscopy with fast wide-field CCD detection. The technique allows for doubling the lateral optical resolution in fluorescence imaging. The physical principle behind ISM is similar to structured illumination microscopy, by combining the resolving power of confocal-laser scanning microscopy with that of a wide-field imaging microscopy. This Letter describes the theoretical foundation and experimental realization of ISM.
- 24 February 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (10) , 1286-1292
Application of dual-focus fluorescence correlation spectroscopy to microfluidic flow-velocity measurement
Several methods exist to measure and map fluid velocities in microfluidic devices, which are vital to understanding properties on the micro- and nano-scale. Fluorescence correlation spectroscopy (FCS) is a method traditionally exploited for its ability to measure molecular diffusion coefficients. However, several reports during the past decade have shown that FCS can also be successfully used to measure precise flow rates in microfluidics with very high spatial resolution, making it a competitive alternative to other common flow-measurement methods. In 2007 we introduced a modified version of conventional FCS that overcomes many of the artifacts troubling the standard technique. Here we show how the advantages of this method, called dual-focus FCS, extend to flow measurements. To do so, we have measured the velocity flow profile along the cross-section of a square-bore microfluidic channel and compared the result to the theoretical prediction.
- 24 February 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (10) , 1286-1292
Application of dual-focus fluorescence correlation spectroscopy to microfluidic flow-velocity measurement
Several methods exist to measure and map fluid velocities in microfluidic devices, which are vital to understanding properties on the micro- and nano-scale. Fluorescence correlation spectroscopy (FCS) is a method traditionally exploited for its ability to measure molecular diffusion coefficients. However, several reports during the past decade have shown that FCS can also be successfully used to measure precise flow rates in microfluidics with very high spatial resolution, making it a competitive alternative to other common flow-measurement methods. In 2007 we introduced a modified version of conventional FCS that overcomes many of the artifacts troubling the standard technique. Here we show how the advantages of this method, called dual-focus FCS, extend to flow measurements. To do so, we have measured the velocity flow profile along the cross-section of a square-bore microfluidic channel and compared the result to the theoretical prediction.
- Top Cited Papers
- 29 December 2009
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 106 (52) , 22287-22292
Fast, background-free, 3D super-resolution optical fluctuation imaging (SOFI)
Super-resolution optical microscopy is a rapidly evolving area of fluorescence microscopy with a tremendous potential for impacting many fields of science. Several super-resolution methods have been developed over the last decade, all capable of overcoming the fundamental diffraction limit of light. We present here an approach for obtaining subdiffraction limit optical resolution in all three dimensions. This method relies on higher-order statistical analysis of temporal fluctuations (caused by fluorescence blinking/intermittency) recorded in a sequence of images (movie). We demonstrate a 5-fold improvement in spatial resolution by using a conventional wide-field microscope. This resolution enhancement is achieved in iterative discrete steps, which in turn allows the evaluation of images at different resolution levels. Even at the lowest level of resolution enhancement, our method features significant background reduction and thus contrast enhancement and is demonstrated on quantum dot-labeled microtubules of fibroblast cells.
- 29 December 2009
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 106 (52) , 22287-22292
Top Cited PapersFast, background-free, 3D super-resolution optical fluctuation imaging (SOFI)
Super-resolution optical microscopy is a rapidly evolving area of fluorescence microscopy with a tremendous potential for impacting many fields of science. Several super-resolution methods have been developed over the last decade, all capable of overcoming the fundamental diffraction limit of light. We present here an approach for obtaining subdiffraction limit optical resolution in all three dimensions. This method relies on higher-order statistical analysis of temporal fluctuations (caused by fluorescence blinking/intermittency) recorded in a sequence of images (movie). We demonstrate a 5-fold improvement in spatial resolution by using a conventional wide-field microscope. This resolution enhancement is achieved in iterative discrete steps, which in turn allows the evaluation of images at different resolution levels. Even at the lowest level of resolution enhancement, our method features significant background reduction and thus contrast enhancement and is demonstrated on quantum dot-labeled microtubules of fibroblast cells.
- 9 February 2009
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 5 (7) , 1358-1366
Dual-focus fluorescence correlation spectroscopy: a robust tool for studying molecular crowding
Conventional single-focus fluorescence correlation spectroscopy (FCS) is often used for studying molecular diffusion in crowded environments. However, these measurements usually deal with concentrations of the crowding agent far beyond the overlap-concentration, resulting in a crowding effect which slows down the diffusion coefficient by several orders of magnitude. In the present paper, we would like to study the transition range from free diffusion to crowding. Therefore, high accuracy of the determination of the diffusion coefficient is needed. In the majority of cases, the local refractive index in a sample is different from the refractive index of the immersion medium of the used objective. To achieve a high accuracy during experiments it is necessary to account for the refractive index mismatch in single-focus FCS calculations. In this work, we study theoretically and experimentally the influence of the refractive index mismatch on performance of single-focus FCS as well as the recently developed dual-focus FCS (2fFCS). By looking at the transition from free tracer diffusion to crowding it is shown that, in contrast to conventional FCS, 2fFCS allows measuring absolute values of the diffusion coefficient and its change in the range of half an order of magnitude. Even under conditions of strong refractive index mismatch between sample and immersion medium, without the need of additional calibration. This is demonstrated on a system of fluorescently labeled 70 kDa dextrane in an unlabeled 70 kDa dextrane matrix. Therefore, 2fFCS is a perfect tool for investigating molecular dynamics in crowded environments.
- 9 February 2009
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 5 (7) , 1358-1366
Dual-focus fluorescence correlation spectroscopy: a robust tool for studying molecular crowding
Conventional single-focus fluorescence correlation spectroscopy (FCS) is often used for studying molecular diffusion in crowded environments. However, these measurements usually deal with concentrations of the crowding agent far beyond the overlap-concentration, resulting in a crowding effect which slows down the diffusion coefficient by several orders of magnitude. In the present paper, we would like to study the transition range from free diffusion to crowding. Therefore, high accuracy of the determination of the diffusion coefficient is needed. In the majority of cases, the local refractive index in a sample is different from the refractive index of the immersion medium of the used objective. To achieve a high accuracy during experiments it is necessary to account for the refractive index mismatch in single-focus FCS calculations. In this work, we study theoretically and experimentally the influence of the refractive index mismatch on performance of single-focus FCS as well as the recently developed dual-focus FCS (2fFCS). By looking at the transition from free tracer diffusion to crowding it is shown that, in contrast to conventional FCS, 2fFCS allows measuring absolute values of the diffusion coefficient and its change in the range of half an order of magnitude. Even under conditions of strong refractive index mismatch between sample and immersion medium, without the need of additional calibration. This is demonstrated on a system of fluorescently labeled 70 kDa dextrane in an unlabeled 70 kDa dextrane matrix. Therefore, 2fFCS is a perfect tool for investigating molecular dynamics in crowded environments.