Seymour Furman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seymour Furman has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Anne B. Curtis
Montefiore Medical Center, Bronx, New York and the University of Florida, Gainesville, Florida
1 shared publicationDmitriy Layvand
Division of Cardiology, Department of Medicine, Montefiore Medical Center and the Albert Einstein College of Medicine, New York
1 shared publicationGeorge Szarka
Division of Cardiology, Department of Medicine, Montefiore Medical Center and the Albert Einstein College of Medicine, New York
1 shared publicationJamie Beth Conti
Montefiore Medical Center, Bronx, New York and the University of Florida, Gainesville, Florida
1 shared publication
Latest Publications
- 3 May 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (5) , 446-453
Reconstruction of Hyman's Second Pacemaker
Though journal articles and newspaper reports suggest that three Hyman pacemakers existed or were intended; a patent, descriptive photographs and a written description of an earlier model and only a photograph of a later model exist. A replica of the earlier has been made based on the patent and description, and a new replica of the second based on a critical deconstruction and analysis of the photograph of the second with a modern circuit duplicating the function of the earlier circuit. Both replicas were “operational” in that stimuli were mimicked though not delivered and neither could under any circumstances actually resuscitate the heart. The design and construction of the second Hyman pacemaker are presented.
- 3 May 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (5) , 446-453
Reconstruction of Hyman's Second Pacemaker
Though journal articles and newspaper reports suggest that three Hyman pacemakers existed or were intended; a patent, descriptive photographs and a written description of an earlier model and only a photograph of a later model exist. A replica of the earlier has been made based on the patent and description, and a new replica of the second based on a critical deconstruction and analysis of the photograph of the second with a modern circuit duplicating the function of the earlier circuit. Both replicas were “operational” in that stimuli were mimicked though not delivered and neither could under any circumstances actually resuscitate the heart. The design and construction of the second Hyman pacemaker are presented.
- 1 October 2003
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 26 (10) , 2023-2032
The Early History of Cardiac Pacing
- 1 October 2003
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 26 (10) , 2023-2032
The Early History of Cardiac Pacing
- 1 August 2001
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 24 (8) , 1224-1227
Recognition and Correction of Subcuticular Malposition of Pacemaker Pulse Generators
FURMAN, S., et al.: Recognition and Correction of Subcuticular Malposition of Pacemaker Pulse Generators. Implantation of a cardiac pacemaker should be in the tissue plane deep to the subcutaneous t...
- 1 August 2001
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 24 (8) , 1224-1227
Recognition and Correction of Subcuticular Malposition of Pacemaker Pulse Generators
FURMAN, S., et al.: Recognition and Correction of Subcuticular Malposition of Pacemaker Pulse Generators. Implantation of a cardiac pacemaker should be in the tissue plane deep to the subcutaneous t...