Wayne F. Patton
Research Subjects
Research Interests
Wayne F. Patton has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Birte Schulenberg
Proteomics Section, Molecular Probes Inc., 4849 Pitchford Avenue, Eugene, OR 97402, USA
8 shared publicationsThomas H. Steinberg
Molecular Probes, Eugene, OR, USA
6 shared publicationsJoseph M. Beechem
Proteomics Section, Molecular Probes Inc., 4849 Pitchford Avenue, Eugene, OR 97402, USA
4 shared publicationsKaren Martin
Proteomics Section, Molecular Probes Inc., 29851 Willow Creek Road, Eugene, OR 97402, USA
4 shared publicationsCourtenay Hart
Proteomics Section, Molecular Probes, Eugene, OR, USA
3 shared publicationsKyle R. Gee
Molecular Probes, Eugene, OR, USA
3 shared publications
Latest Publications
- 2 August 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (15) , 2506-2510
Optimized conditions for diluting and reusing a fluorescent protein gel stain
- 2 August 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (15) , 2506-2510
Optimized conditions for diluting and reusing a fluorescent protein gel stain
- 5 August 2003
- Published by Elsevier in Journal of Chromatography B
- Vol. 793 (1) , 127-139
Mapping glycosylation changes related to cancer using the Multiplexed Proteomics technology: a protein differential display approach
- 5 August 2003
- Published by Elsevier in Journal of Chromatography B
- Vol. 793 (1) , 127-139
Mapping glycosylation changes related to cancer using the Multiplexed Proteomics technology: a protein differential display approach
- 14 July 2003
- Published by Wiley in Proteomics
- Vol. 3 (7) , 1128-1144
Global quantitative phosphoprotein analysis using Multiplexed Proteomics technology
Systematic parallel analysis of the phosphorylation status of networks of interacting proteins involved in the regulatory circuitry of cells and tissues is certain to drive research in the post‐genomics era for many years to come. Reversible protein phosphorylation plays a critical regulatory role in a multitude of cellular processes, including alterations in signal transduction pathways related to oncogene and tumor suppressor gene products in cancer. While fluorescence detection methods are likely to offer the best solution to global protein quantitation in proteomics, to date, there has been no satisfactory method for the specific and reversible fluorescent detection of gel‐separated phosphoproteins from complex samples. The newly developed Pro‐Q Diamond phosphoprotein dye technology is suitable for the fluorescent detection of phosphoserine‐, phosphothreonine‐, and phosphotyrosine‐containing proteins directly in sodium dodecyl sulfate (SDS)‐polyacrylamide gels and two‐dimensional (2‐D) gels. Additionally, the technology is appropriate for the determination of protein kinase and phosphatase substrate preference. Other macromolecules, such as DNA, RNA, and sulfated glycans, fail to be detected with Pro‐Q Diamond dye. The staining procedure is rapid, simple to perform, readily reversible and fully compatible with modern microchemical analysis procedures, such as matrix‐assisted laser desorption/ionization‐time of flight (MALDI‐TOF) mass spectrometry. Pro‐Q Diamond dye technology can detect as little as 1–2 ng of β‐casein, a pentaphosphorylated protein, and 8 ng of pepsin, a monophosphorylated protein. Fluorescence signal intensity correlates with the number of phosphorylated residues on the protein. Through combination of Pro‐Q Diamond phosphoprotein stain with SYPRO® Ruby protein gel stain, Multiplexed Proteomics technology permits quantitative, dichromatic fluorescence detection of proteins in 2‐D gels. This evolving discovery platform allows the parallel determination of protein expression level changes and altered post‐translational modification patterns within a single 2‐D gel experiment. The linear responses of the fluorescence dyes utilized, allow rigorous quantitation of changes over an unprecedented 500–1000‐fold concentration range.
- 14 July 2003
- Published by Wiley in Proteomics
- Vol. 3 (7) , 1128-1144
Global quantitative phosphoprotein analysis using Multiplexed Proteomics technology
Systematic parallel analysis of the phosphorylation status of networks of interacting proteins involved in the regulatory circuitry of cells and tissues is certain to drive research in the post‐genomics era for many years to come. Reversible protein phosphorylation plays a critical regulatory role in a multitude of cellular processes, including alterations in signal transduction pathways related to oncogene and tumor suppressor gene products in cancer. While fluorescence detection methods are likely to offer the best solution to global protein quantitation in proteomics, to date, there has been no satisfactory method for the specific and reversible fluorescent detection of gel‐separated phosphoproteins from complex samples. The newly developed Pro‐Q Diamond phosphoprotein dye technology is suitable for the fluorescent detection of phosphoserine‐, phosphothreonine‐, and phosphotyrosine‐containing proteins directly in sodium dodecyl sulfate (SDS)‐polyacrylamide gels and two‐dimensional (2‐D) gels. Additionally, the technology is appropriate for the determination of protein kinase and phosphatase substrate preference. Other macromolecules, such as DNA, RNA, and sulfated glycans, fail to be detected with Pro‐Q Diamond dye. The staining procedure is rapid, simple to perform, readily reversible and fully compatible with modern microchemical analysis procedures, such as matrix‐assisted laser desorption/ionization‐time of flight (MALDI‐TOF) mass spectrometry. Pro‐Q Diamond dye technology can detect as little as 1–2 ng of β‐casein, a pentaphosphorylated protein, and 8 ng of pepsin, a monophosphorylated protein. Fluorescence signal intensity correlates with the number of phosphorylated residues on the protein. Through combination of Pro‐Q Diamond phosphoprotein stain with SYPRO® Ruby protein gel stain, Multiplexed Proteomics technology permits quantitative, dichromatic fluorescence detection of proteins in 2‐D gels. This evolving discovery platform allows the parallel determination of protein expression level changes and altered post‐translational modification patterns within a single 2‐D gel experiment. The linear responses of the fluorescence dyes utilized, allow rigorous quantitation of changes over an unprecedented 500–1000‐fold concentration range.
- 14 July 2003
- Published by Wiley in Proteomics
- Vol. 3 (7) , 1196-1205
An improved mechanically durable electrophoresis gel matrix that is fully compatible with fluorescence‐based protein detection technologies
Unfortunately, conventional large‐format polyacrylamide gels are mechanically fragile, often tearing during the subsequent manipulations required for visualization of the proteins. This problem is compounded when large‐format two‐dimensional gels are subjected to multiple staining procedures in order to detect different classes of proteins, such as total protein, phosphoproteins, and glycoproteins. A mechanically durable liquid polyacrylamide‐based matrix has been developed that, upon polymerization, facilitates the handling of one‐dimensional and two‐dimensional gels. The matrix, referred to as Rhinohide liquid acrylamide, is stable as a refrigerated solution for up to one year, and forms a polymer‐reinforced polyacrylamide gel suitable for electrophoresis, upon addition of catalysts. The matrix is superior to previously reported durable gel matrices in that it does not cause distortion of high‐molecular‐weight bands and does not suffer from other spot morphology artifacts, such as doubling of protein spots in the molecular weight dimension. The matrix is particularly valuable for the analysis of proteins applying multiple applications of fluorescent dyes, as required with serial staining of proteins for phosphorylation, glycosylation, and total protein expression, using Pro‐Q Diamond phosphoprotein stain, Pro‐Q Emerald glycoprotein stain and SYPRO® Ruby protein gel stain, respectively.
- 14 July 2003
- Published by Wiley in Proteomics
- Vol. 3 (7) , 1196-1205
An improved mechanically durable electrophoresis gel matrix that is fully compatible with fluorescence‐based protein detection technologies
Unfortunately, conventional large‐format polyacrylamide gels are mechanically fragile, often tearing during the subsequent manipulations required for visualization of the proteins. This problem is compounded when large‐format two‐dimensional gels are subjected to multiple staining procedures in order to detect different classes of proteins, such as total protein, phosphoproteins, and glycoproteins. A mechanically durable liquid polyacrylamide‐based matrix has been developed that, upon polymerization, facilitates the handling of one‐dimensional and two‐dimensional gels. The matrix, referred to as Rhinohide liquid acrylamide, is stable as a refrigerated solution for up to one year, and forms a polymer‐reinforced polyacrylamide gel suitable for electrophoresis, upon addition of catalysts. The matrix is superior to previously reported durable gel matrices in that it does not cause distortion of high‐molecular‐weight bands and does not suffer from other spot morphology artifacts, such as doubling of protein spots in the molecular weight dimension. The matrix is particularly valuable for the analysis of proteins applying multiple applications of fluorescent dyes, as required with serial staining of proteins for phosphorylation, glycosylation, and total protein expression, using Pro‐Q Diamond phosphoprotein stain, Pro‐Q Emerald glycoprotein stain and SYPRO® Ruby protein gel stain, respectively.
- 14 July 2003
- Published by Wiley in Proteomics
- Vol. 3 (7) , 1244-1255
Quantitative analysis of protein phosphorylation status and protein kinase activity on microarrays using a novel fluorescent phosphorylation sensor dye
Ultrasensitive detection of minute amounts of phosphorylated proteins and peptides is a key requirement for unraveling many of the most important signal transduction pathways in mammalian systems. Protein microarrays are potentially useful tools for sensitive screening of global protein expression and post‐translational modifications, such as phosphorylation. However, the analysis of signaling pathways has been hampered by a lack of reagents capable of conveniently detecting the targets of protein kinases. Historically, phosphorylation detection methods have relied upon either radioisotopes ((γ‐32P)ATP(γ‐33P)ATP labeling) or phosphoamino acid‐selective antibodies. Both of these methods suffer from relatively well‐known shortcomings. In this study, a small molecule fluorophore phosphosensor technology is described, referred to as Pro‐Q Diamond dye, which is capable of ultrasensitive global detection and quantitation of phosphorylated amino acid residues in peptides and proteins displayed on microarrays. The utility of the fluorescent Pro‐Q Diamond phosphosensor dye technology is demonstrated using phosphoproteins and phosphopeptides as well as with protein kinase reactions performed in miniaturized microarray assay format. Instead of applying a phosphoamino acid‐selective antibody labeled with a fluorescent or enzymatic tag for detection, a small, fluorescent probe is employed as a universal sensor of phosphorylation status. The detection limit for phosphoproteins on a variety of different commercially available protein array substrates was found to be 312–625 fg, depending upon the number of phosphate residues. Characterization of the enzymatic phosphorylation of immobilized peptide targets with Pro‐Q Diamond dye readily permits differentiation between specific and non‐specific peptide labeling at picogram to subpicogram levels of detection sensitivity.
- 14 July 2003
- Published by Wiley in Proteomics
- Vol. 3 (7) , 1244-1255
Quantitative analysis of protein phosphorylation status and protein kinase activity on microarrays using a novel fluorescent phosphorylation sensor dye
Ultrasensitive detection of minute amounts of phosphorylated proteins and peptides is a key requirement for unraveling many of the most important signal transduction pathways in mammalian systems. Protein microarrays are potentially useful tools for sensitive screening of global protein expression and post‐translational modifications, such as phosphorylation. However, the analysis of signaling pathways has been hampered by a lack of reagents capable of conveniently detecting the targets of protein kinases. Historically, phosphorylation detection methods have relied upon either radioisotopes ((γ‐32P)ATP(γ‐33P)ATP labeling) or phosphoamino acid‐selective antibodies. Both of these methods suffer from relatively well‐known shortcomings. In this study, a small molecule fluorophore phosphosensor technology is described, referred to as Pro‐Q Diamond dye, which is capable of ultrasensitive global detection and quantitation of phosphorylated amino acid residues in peptides and proteins displayed on microarrays. The utility of the fluorescent Pro‐Q Diamond phosphosensor dye technology is demonstrated using phosphoproteins and phosphopeptides as well as with protein kinase reactions performed in miniaturized microarray assay format. Instead of applying a phosphoamino acid‐selective antibody labeled with a fluorescent or enzymatic tag for detection, a small, fluorescent probe is employed as a universal sensor of phosphorylation status. The detection limit for phosphoproteins on a variety of different commercially available protein array substrates was found to be 312–625 fg, depending upon the number of phosphate residues. Characterization of the enzymatic phosphorylation of immobilized peptide targets with Pro‐Q Diamond dye readily permits differentiation between specific and non‐specific peptide labeling at picogram to subpicogram levels of detection sensitivity.
- 14 July 2003
- Published by Wiley in Proteomics
- Vol. 3 (7) , 1215-1227
Simultaneous trichromatic fluorescence detection of proteins on Western blots using an amine‐reactive dye in combination with alkaline phosphatase‐ and horseradish peroxidase‐antibody conjugates
Three‐color fluorescence detection methods are described based upon covalently coupling the dye 2‐methoxy‐2,4‐diphenyl‐2(2 H )‐furanone (MDPF) to proteins immobilized on poly(vinylidene difluoride) (PVDF) membranes, followed by detection of target proteins using alkaline‐phosphatase‐conjugated reporter molecules in combination with the fluorogenic substrate 9 H ‐(1,3‐dichloro‐9,9‐dimethylacridin‐2‐one‐7‐yl) phosphate (DDAO‐phosphate) as well as horseradish peroxidase‐conjugated reporter molecules in combination with the new fluorogenic substrate Amplex® Gold reagent. This results in all proteins in the profile being visualized as fluorescent blue signal, those detected specifically with the alkaline phosphatase conjugate appearing as fluorescent red signal and those detected specifically with the horseradish peroxidase conjugate appearing as fluorescent yellow signal. Using conventional secondary antibodies, two different targets may be identified as long as primary antibodies generated from two different species are used in the analysis. However, Zenon antibody labeling technology eliminates this restriction, permitting the simultaneous use of two different mouse monoclonal antibodies or two different rabbit polyclonal antibodies in the same electroblotting experiment. The trichromatic detection system is broadly compatible with UV epi‐illuminators combined with photographic or charge‐coupled device (CCD) cameras, and xenon‐arc sources equipped with appropriate excitation/emission filters. Alternatively, the enzyme conjugates may be detected using a laser‐based gel scanner. The trichromatic method permits detection of low nanogram amounts of protein and allows for unambiguous identification of two different target proteins relative to the entire protein profile on a single electroblot, precluding any requirement for running replicate gels that would otherwise require separate visualization of total proteins and subsequent alignment with multiple chemiluminescent or colorimetric signals generated on different electroblots.
- 14 July 2003
- Published by Wiley in Proteomics
- Vol. 3 (7) , 1215-1227
Simultaneous trichromatic fluorescence detection of proteins on Western blots using an amine‐reactive dye in combination with alkaline phosphatase‐ and horseradish peroxidase‐antibody conjugates
Three‐color fluorescence detection methods are described based upon covalently coupling the dye 2‐methoxy‐2,4‐diphenyl‐2(2 H )‐furanone (MDPF) to proteins immobilized on poly(vinylidene difluoride) (PVDF) membranes, followed by detection of target proteins using alkaline‐phosphatase‐conjugated reporter molecules in combination with the fluorogenic substrate 9 H ‐(1,3‐dichloro‐9,9‐dimethylacridin‐2‐one‐7‐yl) phosphate (DDAO‐phosphate) as well as horseradish peroxidase‐conjugated reporter molecules in combination with the new fluorogenic substrate Amplex® Gold reagent. This results in all proteins in the profile being visualized as fluorescent blue signal, those detected specifically with the alkaline phosphatase conjugate appearing as fluorescent red signal and those detected specifically with the horseradish peroxidase conjugate appearing as fluorescent yellow signal. Using conventional secondary antibodies, two different targets may be identified as long as primary antibodies generated from two different species are used in the analysis. However, Zenon antibody labeling technology eliminates this restriction, permitting the simultaneous use of two different mouse monoclonal antibodies or two different rabbit polyclonal antibodies in the same electroblotting experiment. The trichromatic detection system is broadly compatible with UV epi‐illuminators combined with photographic or charge‐coupled device (CCD) cameras, and xenon‐arc sources equipped with appropriate excitation/emission filters. Alternatively, the enzyme conjugates may be detected using a laser‐based gel scanner. The trichromatic method permits detection of low nanogram amounts of protein and allows for unambiguous identification of two different target proteins relative to the entire protein profile on a single electroblot, precluding any requirement for running replicate gels that would otherwise require separate visualization of total proteins and subsequent alignment with multiple chemiluminescent or colorimetric signals generated on different electroblots.
- 1 June 2003
- Published by Bentham Science Publishers Ltd. in Combinatorial Chemistry & High Throughput Screening
- Vol. 6 (4) , 331-339
Strategies and Solid-Phase Formats for the Analysis of Protein and Peptide Phosphorylation Employing A Novel Fluorescent Phosphorylation Sensor Dye
Protein kinases represent one of the largest families of regulatory enzymes, with more than 2,000 of them being encoded for by the human genome. Many cellular processes are regulated by the reversible phosphorylation of proteins and upwards of 30% of the proteins comprising the eukaryotic proteome are likely to be phosphorylated at some point during their existence. In the past, analysis of global protein phosphorylation has been accomplished through radiolabelling of samples with inorganic 32P or [γ-32P] ATP. The approach is limited to specimens amenable to radiolabelling and poses certain safety and disposal problems. Alternatively, immunodetection with antibodies to the common phosphoamino acids may be employed, but the antibodies are relatively expensive and exhibit limited specificity and a certain degree of cross-reactivity. Pro-Q Diamond dye is a new fluorescent phosphosensor technology suitable for the detection of phosphoserine-, phosphothreonine- and phosphotyrosine-containing proteins directly in isoelectric focusing gels, SDS-polyacrylamide gels and two-dimensional gels. Additionally, the technology is appropriate for the detection of phosphoproteins or phosphopeptides arrayed on protein chips or affixed to beads. Dye-stained proteins and peptides can be excited with a laser-based light source of 532 or 543 nm or with a xenon-arc lamp-based system equipped with appropriate band pass filters. Alternatively, ultraviolet light of about 302 nm may be employed, providing that sufficiently long exposure times are used to collect the fluorescence signal. Pro-Q Diamond dye emits maximally at approximately 580 nm. The fluorescence-based detection technology is easy to conduct, cost effective and allows rapid large-scale screening of protein and peptide phosphorylation in a variety of solid-phase assay formats.
- 1 June 2003
- Published by Bentham Science Publishers Ltd. in Combinatorial Chemistry & High Throughput Screening
- Vol. 6 (4) , 331-339
Strategies and Solid-Phase Formats for the Analysis of Protein and Peptide Phosphorylation Employing A Novel Fluorescent Phosphorylation Sensor Dye
Protein kinases represent one of the largest families of regulatory enzymes, with more than 2,000 of them being encoded for by the human genome. Many cellular processes are regulated by the reversible phosphorylation of proteins and upwards of 30% of the proteins comprising the eukaryotic proteome are likely to be phosphorylated at some point during their existence. In the past, analysis of global protein phosphorylation has been accomplished through radiolabelling of samples with inorganic 32P or [γ-32P] ATP. The approach is limited to specimens amenable to radiolabelling and poses certain safety and disposal problems. Alternatively, immunodetection with antibodies to the common phosphoamino acids may be employed, but the antibodies are relatively expensive and exhibit limited specificity and a certain degree of cross-reactivity. Pro-Q Diamond dye is a new fluorescent phosphosensor technology suitable for the detection of phosphoserine-, phosphothreonine- and phosphotyrosine-containing proteins directly in isoelectric focusing gels, SDS-polyacrylamide gels and two-dimensional gels. Additionally, the technology is appropriate for the detection of phosphoproteins or phosphopeptides arrayed on protein chips or affixed to beads. Dye-stained proteins and peptides can be excited with a laser-based light source of 532 or 543 nm or with a xenon-arc lamp-based system equipped with appropriate band pass filters. Alternatively, ultraviolet light of about 302 nm may be employed, providing that sufficiently long exposure times are used to collect the fluorescence signal. Pro-Q Diamond dye emits maximally at approximately 580 nm. The fluorescence-based detection technology is easy to conduct, cost effective and allows rapid large-scale screening of protein and peptide phosphorylation in a variety of solid-phase assay formats.
- 24 February 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (4) , 588-598
Detection of glycoproteins in polyacrylamide gels and on electroblots using Pro‐Q Emerald 488 dye, a fluorescent periodate Schiff‐base stain
Pro‐Q Emerald 488 glycoprotein stain reacts with periodic acid‐oxidized carbohydrate groups, generating a bright green‐fluorescent signal on glycoproteins. The stain permits detection of less than 5–18 ng of glycoprotein per band, depending upon the nature and the degree of protein glycosylation, making it roughly 8–16‐fold more sensitive than the standard colorimetric periodic acid‐Schiff base method using acidic fuchsin dye (pararosaniline). The green‐fluorescent signal from Pro‐Q Emerald 488 stain may optimally be visualized using charge‐coupled device/xenon arc lamp‐based imaging systems or 470–488 nm laser‐based gel scanners. Though glycoprotein detection may be performed on transfer membranes, direct detection in gels avoids electroblotting and the specificity of staining is better in gels. After detecting glycoproteins with Pro‐Q Emerald 488 dye, total protein profiles may subsequently be detected using SYPRO Ruby protein gel stain. Using computer‐assisted registration techniques, images may then be merged to generate differential display maps.
- 24 February 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (4) , 588-598
Detection of glycoproteins in polyacrylamide gels and on electroblots using Pro‐Q Emerald 488 dye, a fluorescent periodate Schiff‐base stain
Pro‐Q Emerald 488 glycoprotein stain reacts with periodic acid‐oxidized carbohydrate groups, generating a bright green‐fluorescent signal on glycoproteins. The stain permits detection of less than 5–18 ng of glycoprotein per band, depending upon the nature and the degree of protein glycosylation, making it roughly 8–16‐fold more sensitive than the standard colorimetric periodic acid‐Schiff base method using acidic fuchsin dye (pararosaniline). The green‐fluorescent signal from Pro‐Q Emerald 488 stain may optimally be visualized using charge‐coupled device/xenon arc lamp‐based imaging systems or 470–488 nm laser‐based gel scanners. Though glycoprotein detection may be performed on transfer membranes, direct detection in gels avoids electroblotting and the specificity of staining is better in gels. After detecting glycoproteins with Pro‐Q Emerald 488 dye, total protein profiles may subsequently be detected using SYPRO Ruby protein gel stain. Using computer‐assisted registration techniques, images may then be merged to generate differential display maps.
- 1 August 2002
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 13 (4) , 321-328
Two-dimensional gel electrophoresis; better than a poke in the ICAT?
- 1 August 2002
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 13 (4) , 321-328
Two-dimensional gel electrophoresis; better than a poke in the ICAT?
- 1 May 2002
- Published by Elsevier in Journal of Chromatography B
- Vol. 771 (1-2) , 3-31
Detection technologies in proteome analysis
- 1 May 2002
- Published by Elsevier in Journal of Chromatography B
- Vol. 771 (1-2) , 3-31
Detection technologies in proteome analysis