Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven H. Elder has a total of 106 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Neurophysiological and Biomechanical Determinants of Successful Basketball Throws

    by P. K. Phan, A.T.N. Vo, D. Saucier, S. Elder, F. To, R. Burch, H. Chander, S. Sharma, D. Vandenheever

    This study investigates the neurophysiological and biomechanical factors contributing to successful basketball throw performance in novice athletes, utilizing electroencephalography (EEG) and motion capture (MoCap) to analyze joint angles, ground reaction forces (GRFs), and brain activity. Sixteen participants performed basketball throws while EEG and MoCap systems recorded data on movement mechanics and neural activity. Biomechanical findings revealed that successful trials were characterized by refined movements, reduced wrist extension, increased elbow flexion, and more stable foot positioning compared to unsuccessful trials (all p > 0.05), contributing to greater shot accuracy. Reduced movement variability in successful trials further indicated improved motor consistency, reflective of skill development. EEG results showed higher beta and gamma power in the temporal lobe during successful compared to unsuccessful trials (p < 0.05), suggesting increased engagement in visuomotor integration and neural efficiency. Notably, our novice participants demonstrated limited neural efficiency in frontal regions (p > 0.05), potentially due to cognitive interference and self-monitoring. These findings highlight the importance of coordinated biomechanical execution and neural efficiency in optimizing basketball performance. The insights gained have practical implications for designing training interventions that improve motor performance, particularly for novice athletes.


  • Open Access

    In Silico Insights into the Inhibition of ADAMTS-5 by Punicalagin and Ellagic Acid for the Treatment of Osteoarthritis

    by Austen N. Breland, Matthew K. Ross, Nicholas C. Fitzkee, Steven H. Elder

    ADAMTS-5 (aggrecanase-2) is a major metalloprotease involved in regulating the cartilage extracellular matrix. Due to its role in removing aggrecan in the progression of osteoarthritis (OA), ADAMTS-5 is often regarded as a potential therapeutic target for OA. Punicalagin (PCG), a polyphenolic ellagitannin found in pomegranate (Punica grunatum L.), and ellagic acid (EA), a hydrolytic metabolite of PCG, have been widely investigated as potential disease-modifying osteoarthritis drugs (DMOADs) due to their potent antioxidant and anti-inflammatory properties, but their interaction with ADAMTS-5 has yet to be determined. In this study, molecular docking simulations were used to predict enzyme–inhibitor binding interactions. The results suggest that both compounds may be able to bind within the active site via the formation of H bonds and interactions between the ligand’s aromatic rings and hydrophobic residue in the enzyme with inhibition constants of 183.3 µM and 1.13 µM for PCG and EA, respectively. Biochemical activity against recombinant human ADAMTS-5 was assessed using a dimethylmethylene blue-based assay to determine residual sulfated glycosaminoglycan (sGAG) in porcine articular cartilage. Although its loss could not be attributed to ADAMTS-5, sGAG was effectively persevered by PCG and EA. The potential conversion of PCG to EA by enzyme-catalyzed hydrolysis activity was then investigated using liquid chromatography–mass spectroscopy to determine the potential for the use of PCG and EA as a prodrug–proactive metabolite pair in the development of drug delivery systems to arthritic synovial joints.


  • Open Access

    Theoretical model of impact mitigation mechanisms inherent to the North American bison skull

    by Andrea Karen Persons, Youssef Hammi, Steven H. Elder, Lauren B. Priddy, Matthew W. Priddy, Ryan Butler, Avery Schemmel, Elizabeth Whitehurst, Nayeon Lee, Mark F. Horstemeyer

    North American bison (Bovidae: Bison bison) incur blunt impacts to the interparietal and frontal bones when they engage in head-to-head fights. To investigate the impact mitigation of these bones, a finite element analysis (FEA) of the skull under loading conditions was performed. Based on anatomical and histological studies, the interparietal and frontal bones are both comprised of a combination of haversian and plexiform bone and are both underlain by bony septa. Additionally, the interparietal bone is thicker than the frontal bone. Data regarding the mechanical properties of bison bone are scarce, but the results of a phylogenetic analysis infer that the material properties of the closely related domestic cow bone are a suitable proxy for use in the FEA. Results of the FEA suggest that the thickness of the interparietal bone in conjunction with the bony septa may prevent fracture stresses by helping to absorb and disperse the blunt impact energy throughout the skull. Monotonic stress levels of 294 MPa, which are below the compressive strength of bone were exhibited in the simulated bison head impacts indicating no fracture of the bones.


  • Development of in situ forming implants for controlled delivery of punicalagin

    by Steven H. Elder, Matthew K. Ross, Ashleigh J. Nicaise, Isaac N. Miller, Austen N. Breland, Ariory R.S. Hood


  • Open Access

    Comparison of the Capacitance of a Cyclically Fatigued Stretch Sensor to a Non-Fatigued Stretch Sensor When Performing Static and Dynamic Foot-Ankle Motions

    by Andrea Karen Persons, Carver Middleton, Erin Parker, Will Carroll, Alana Turner, Purva Talegaonkar, Samaneh Davarzani, David Saucier, Harish Chander, John E. Ball, et al.

    Motion capture is the current gold standard for assessing movement of the human body, but laboratory settings do not always mimic the natural terrains and movements encountered by humans. To overcome such limitations, a smart sock that is equipped with stretch sensors is being developed to record movement data outside of the laboratory. For the smart sock stretch sensors to provide valuable feedback, the sensors should have durability of both materials and signal. To test the durability of the stretch sensors, the sensors were exposed to high-cycle fatigue testing with simultaneous capture of the capacitance. Following randomization, either the fatigued sensor or an unfatigued sensor was placed in the plantarflexion position on the smart sock, and participants were asked to complete the following static movements: dorsiflexion, inversion, eversion, and plantarflexion. Participants were then asked to complete gait trials. The sensor was then exchanged for either an unfatigued or fatigued plantarflexion sensor, depending upon which sensor the trials began with, and each trial was repeated by the participant using the opposite sensor. Results of the tests show that for both the static and dynamic movements, the capacitive output of the fatigued sensor was consistently higher than that of the unfatigued sensor suggesting that an upwards drift of the capacitance was occurring in the fatigued sensors. More research is needed to determine whether stretch sensors should be pre-stretched prior to data collection, and to also determine whether the drift stabilizes once the cyclic softening of the materials comprising the sensor has stabilized.


  • Biomechanical Comparison of a Headless Compression Screw Fastener and AO Cortical Bone Screw for Fixation of a Simulated Equine Third Carpal Bone Slab Fracture

    by Allison Salinger, Cathleen Mochal-King, Kailey Clinton, Lauren B. Priddy, Steve Elder, Robin Fontenot, Alison Eddy, Robert Wills, Michael Jaffe


  • Open Access

    Evaluation of Electrospun PCL-PLGA for Sustained Delivery of Kartogenin

    by Steven Elder, John Graham Roberson, James Warren, Robert Lawson, Daniel Young, Sean Stokes, Matthew K. Ross

    In this study, kartogenin was incorporated into an electrospun blend of polycaprolactone and poly(lactic-co-glycolic acid) (1:1) to determine the feasibility of this system for sustained drug delivery. Kartogenin is a small-molecule drug that could enhance the outcome of microfracture, a cartilage restoration procedure, by selectively stimulating chondrogenic differentiation of endogenous bone marrow mesenchymal stem cells. Experimental results showed that kartogenin did not affect the electrospinnability of the polymer blend, and it had negligible effects on fiber morphology and scaffold mechanical properties. The loading efficiency of kartogenin into electrospun membranes was nearly 100%, and no evidence of chemical reaction between kartogenin and the polymers was detected by Fourier transform infrared spectroscopy. Analysis of the released drug using high-performance liquid chromatography–photodiode array detection indicated an abundance of kartogenin and only a small amount of its major hydrolysis product. Kartogenin displayed a typical biphasic release profile, with approximately 30% being released within 24 h followed by a much slower, constant rate of release up to 28 days. Although additional development is needed to tune the release kinetics and address issues common to electrospun scaffolds (e.g., high fiber density), the results of this study demonstrated that a scaffold electrospun from biodegradable synthetic polymers is a suitable kartogenin delivery vehicle.


  • Open Access

    Ex Vivo Biomechanical Comparison of a Novel Headless Compression Screw Fastener and Traditional Ao Cortical Bone Screw for Fixation of a Simulated Slab Fracture in the Equine Third Carpal Bone

    by Allison Salinger, Cathleen Mochal-King, Kailey Clinton, Lauren B. Priddy, Steve Elder, Robin Fontenot, Alison Eddy, Robert Wills, Michael Jaffe

    IntroductionFrontal plane slab fractures account for the majority of third carpal bone (C3) fractures in racing and performance horses. Recommended treatment is stabilization with a lagged AO cortical screw. Associated complications are fragment splitting, fragment spinning, and irritation of dorsal soft tissue structures. A novel, headless, cannulated screw with interlocking threads (the Headless Compression Screw Fastener, HCSF) has been developed to resist multidirectional forces and bending moments; however, it has not been applied in the horse.Experimental Design and MethodsSimulated C3 frontal plane slab fractures were created in nine paired carpi from equine cadaver limbs, fixed with either the HCSF or AO cortical bone screw, and loaded in shear to failure. The effect of screw type on stiffness, maximum load to failure, and yield load was assessed in separate linear mixed models.ResultsNo significant (p <0.05) difference between screw types was detected in terms of maximum load to failure (p= 0.084), stiffness (p= 0.26), or yield load (p= 0.089). Mode of failure was screw bending in all specimens. For some samples in both groups, failure was associated with sagittal fracture at the screw-bone interface.ConclusionThe HCSF was successfully used to repair simulated third carpal bone fractures. The different head and thread pitches of the HCSF effectively compressed the fracture. The headless design eliminates the need for counter sinking. There was no significant difference in maximum load to failure, stiffness, nor yield load compared to the cortical screws. These results invite clinical application to be investigated.

  • Effects of short‐duration treatment of cartilage with punicalagin and genipin and the implications for treatment of osteoarthritis

    by Steven H. Elder, Mark L. Mosher, Paulino Jarquin, Preston Smith, Andrea Chironis

    Punicalagin (PA) not only binds type II collagen, but also blocks its MMP‐13‐mediated degradation, and genipin (GNP) is a collagen cross‐linking agent. We hypothesized that these drugs could mitigate the loss of cartilage if administered in the early phase of osteoarthritis, and experiments were designed to provide proof‐of‐concept. Porcine cartilage was exposed to both drugs in a manner designed to simulate intra‐articular (IA) injection. Based on penetration of PA into cartilage, the rate of drug diffusion was conservatively estimated at 2 μm per minute. GNP caused a measurable degree of cross‐linking, increased compressive resistance and coefficient of friction, and substantially inhibited degradation by collagenase, but not by hyaluronidase. Pre‐incubation of GNP with collagenase had no effect on enzymatic activity. PA did not cross‐link collagen nor affect the mechanical properties of cartilage. It did, however, increase resistance to degradation by collagenase and hyaluronidase. Furthermore, it reacted with collagenase in solution and inhibited its subsequent enzymatic activity. Effects of PA and GNP were not additive. The chondroprotective effect of semi‐weekly IA injections was investigated in the monoiodoacetate‐induced model of OA in rats. Quantitative histology suggested that injection of PA decreased the amount of cartilage lost compared to saline‐injected controls, and the addition of GNP made no difference. This study supports the notion that IA delivery of PA could mitigate OA‐induced cartilage erosion.


  • Open Access

    Ex vivo biomechanical comparison of 2.7 mm string-of-pearl plate versus screw/wire/Polymethylmethacrylate composite fixation and 2.7 mm veterinary acetabular plate for repair of simulated canine acetabular fractures

    by Jonathan A. Blakely, James R. Butler, Lauren B. Priddy, Emily M. McCabe, Javier N. Avendaño, Steve H. Elder, Robert Wills

    Acetabular fractures comprise 12–30% of canine pelvic fractures and require accurate anatomic reduction and rigid stability to ensure proper healing and minimize future osteoarthritis. Many techniques have been used to repair these fractures, with common techniques including veterinary acetabular plates or use of screw/wire/polymethylmethacrylate constructs. String-of-Pearl™ plating systems have also been used clinically but there is a lack of research supporting their use for these fractures. The purpose of this study was to compare fracture reduction accuracy, biomechanical characteristics, and mode of failure between String-of-Pearls™, veterinary acetabular plates, screw/wire/polymethylmethacrylate constructs in a simulated, ex-vivo acetabular fracture model. We hypothesized that the String-of-Pearls™ constructs would have equivalent or greater mechanical properties and reduction compared to the other constructs. The mean craniocaudal acetabular diameter before fixation (mean 25.2 mm; range 20 mm – 30.1 mm) was not significantly different from after fixation (mean 23.9 mm; range 20 mm – 28.3 mm) for any fixation method. Comparison of reduction scores between groups revealed no significant differences. No significant differences were noted for cyclical displacement or stiffness. There was significant difference with superior failure load of String-of-Pearls™ compared to screw/wire/polymethylmethacrylate in the 75th percentile of animal weight (P = 0.0021), and superior failure load of String-of-Pearls™ compared to veterinary acetabular plates in the 50th (P = 0.0232) and 75th percentiles (P = 0.0058). Stiffness of the String-of-Pearls™ construct was significantly greater than the veterinary acetabular plate construct (P = 0.0417). For ultimate load, String-of-Pearls™ constructs were significantly greater than screw/wire/polymethylmethacrylate (P = 0.0331) and veterinary acetabular plates (P = 0.0218). Although the ease of application for the String-of-Pearls™ implant was subjectively better than other implants, no significant differences were found in fracture reduction scores. The String-of-Pearls™ constructs were stiffer than veterinary acetabular plates and exhibited greater failure and ultimate loads compared to veterinary acetabular plates and screw/wire/polymethylmethacrylate fixations. The String-of-Pearls™ implant appears to be a suitable fixation choice for simple canine acetabular fractures.