PFPeter S. Fischbach

Peter S. Fischbach

*This is an algorithmically generated author record based on publicly available information.

Peter S. Fischbach has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Benedict R. Lucchesi

    Departments of Pediatrics and Communicable Diseases (P.S.F.) and Pharmacology University of Michigan Medical School Ann Arbor Michigan

    2 shared publications
  • Terrance D. Barrett

    Departments of Pediatrics and Communicable Diseases (P.S.F.) and Pharmacology University of Michigan Medical School Ann Arbor Michigan

    2 shared publications
  • Andrew White

    Departments of Pediatrics and Communicable Diseases (P.S.F.) and Pharmacology University of Michigan Medical School Ann Arbor Michigan

    1 shared publication
  • Benedict R. Lucchesi M.D.

    Pharmacology, University of Michigan Medical School, Ann Arbor, Michigan

    1 shared publication
  • Binh C. Tran

    1 shared publication
  • Binh C. Tran M.S.

    Internal Medicine, University of Michigan Medical School, Ann Arbor, Michigan

    1 shared publication

Latest Publications

  • Radiofrequency Ablation for Supraventricular Tachycardia in Children ≤15 kg Is Safe and Effective

    by R. Aiyagari, E.V. Saarel, S.P. Etheridge, D.J. Bradley, M. Dick, P.S. Fischbach

    Risks associated with radiofrequency ablation (RFA) have been reported to be increased in children ≤15 kg. We sought to compare the safety and efficacy of RFA in children n = 25) and those between 15.1 and 20 kg (group 2, n = 44). The two groups differed significantly in age and weight by design (group 1: mean weight, 11.9 ± 3.0 kg; age, 2.8 ± 1.9 years; group 2: weight, 18.0 ± 1.5 kg; age, 5.1 ± 1.1 years). There were no significant differences in other baseline characteristics except for incidence of structural heart disease (28% group 1 vs 7% group 2, p < 0.01). No significant differences in mechanism of tachycardia, arrhythmia cycle length, number of total and brief RFA applications, total RFA time, average and maximum RFA temperatures, total procedure duration, short-term success rate (96% group 1 vs 86% group 2, p = 0.17), long-term success rate (91% group 1 vs 89% group 2, p = 0.76), or major complications (8.0% group 1 vs 2.3% group 2, p = 0.39) were found. There were no procedure-related deaths in either group. These data suggest that, in two large volume electrophysiology centers, the procedural risks and outcomes of RFA are similar between patients weighing less than 15 kg and those between 15.1 and 20 kg.


  • Transient atrioventricular conduction block with cryoablation following normal cryomapping

    by Peter S. Fischbach, Elizabeth V. Saarel, MacDonald Dick


  • Open Access

    Risk of Ventricular Proarrhythmia with Selective Opening of the Myocardial Sarcolemmal versus Mitochondrial ATP-Gated Potassium Channel

    by Peter S. Fischbach, Andrew White, Terrance D. Barrett, Benedict R. Lucchesi

    Myocardial ATP-gated potassium channels (K-ATPs) are critical in the intracellular signaling cascade resulting in ischemic preconditioning (IP). Mitochondrial K-ATP channels seem to be responsible for IP, whereas the functions of K-ATP channels in the sarcolemmal membrane are less well understood. The proarrhythmic potential of specific versus nonspecific opening of K-ATP channels has not been investigated. In this study, Langendorff-perfused rabbit hearts were exposed to either pinacidil (1.25 μM), a nonselective K-ATP channel agonist, or selective mitochondrial or sarcolemmal K-ATP channel agonists or antagonists. The hearts were then subjected to 12 min of hypoxic perfusion and 40 min of reoxygenation. Hearts were monitored for the induction of ventricular fibrillation (VF). No heart subjected to hypoxia-reoxygenation without drug treatment developed VF (0 of 5). Pinacidil pretreatment induced VF (12 of 14; p = 0.004 versus control). Pinacidil9s effect was blocked by HMR-1098 (1-[5-[2-(5-chloro-o-anisamide)ethyl]-2-methoxyphenyl]sulfonyl]-3-methylthiourea) (1 μM), a selective sarcolemmal K-ATP channel antagonist (1 of 7; p = 0.007 versus pinacidil; N.S. versus control). Hearts pretreated with 5-hydroxydecanoate (5-HD) (100 μM), a putatively selective mitochondrial K-ATP channel blocker developed VF in one of eight trials (N.S. versus control). 5-HD did not alter the effects of pinacidil (6 of 8; p < 0.05 versus control; N.S. versus pinacidil alone). Selective mitochondrial K-ATP channel activation with [(3R)-trans-4-((4-chlorophenyl)-N-(1H-imidazol-2-ylmethyl)dimethyl-2H-1-benzopyran-6-carbonitril monohydrochloride] (BMS-191095) (6 μM) resulted in zero of five hearts developing VF (N.S. versus control). Our data suggest that selective opening of the sarcolemmal K-ATP channel during hypoxia-reoxygenation induced VF, whereas opening of the mitochondrial channel was not associated with VF. The findings suggest that caution should be exercised when developing compounds aimed at inducing IP, and nonspecific opening of the K-ATP channel should be avoided.


  • Conversion of atrial fibrillation by the experimental antiarrhythmic drug tedisamil in two canine models.

    by Peter S. Fischbach, Terrance D. Barrett, Rajiva Goyal, Binh C. Tran, Zaffer A. Syed, James K. Hennan, Benedict R. Lucchesi, Binh C. Tran M.S., Zaffer A. Syed M.S., Benedict R. Lucchesi M.D.


  • Use of a Single Coil Transvenous Electrode with an Abdominally Placed Implantable Cardioverter Defibrillator in Children

    by Peter S. Fischbach, Ian H. Law, Macdonald Dick Ii, Sarah Leroy, Ralph S. Mosca, Gerald A. Serwer

    While transvenous defibrillator electrode placement avoiding a thoracotomy is preferable, electrode size, a large intercoil spacing, and the need for subclavicular device placement preclude this approach in most children. We investigated a single RV coil to an abdominally placed active can ICD device. Five children ages 8–16 years (weight 21–50 kg, mean 35 kg) underwent ICD placement. Placement of a single coil Medtronic model 6932 or 6943 electrode was performed via the left subclavian vein approach and the electrode positioned in the RV apex with the coil lying along the RV diaphragmatic surface. The ICD (Medtronic Micro Jewel II model 7223Cx) was implanted in a left abdominal pocket with the lead tunneled from the infraclavicular region to the pocket. Implant DFTs were ± 15 J using a biphasic waveform. DFTs rechecked within 3‐month postimplant were unchanged. Lead impedance at implant ranged from 38 to 56 Ω, mean 51 Ω. Follow‐up was 3–21 months (total 82 months) with no electrode dislodgment. lead fractures, or inappropriate discharges. Two of the five patients have had successful appropriate ICD discharges. Transvenous ICD electrode placement can be performed in children as small as 20 kg with the device implanted in a cosmetically acceptable abdominal pocket that is well tolerated. Excellent DFTs can be achieved. This approach avoids a thoracotomy in all but the smallest child, does not require subclavicular placement of the device, and avoids use of a second intravascular coil.