  • SU‐E‐T‐483: Factors Contributing to the Increased Proton RBE at the Distal Edge of Bragg Peak

    by C‐W Cheng, M Takashina, M Suga, Ij Das, V Moskvin

  • 41 POTENTIAL APPLICATIONS OF A GAS ELECTRON MULTIPLIER-BASED DETECTOR TO SMALL FIELD DOSIMETRY AND IMAGING IN PROTON THERAPY

    by D. Nichiporov, A. Klyachko, L. Coutinho, R. Parola, V. Moskvin, C.W. Cheng, I. Das

  • Dose perturbations due to contrast medium and air in MammoSite® treatment: An experimental and Monte Carlo study

    by C.-W. Cheng, R. Mitra, X. Allen Li, Indra J. Das

    In the management of early breast cancer, a partial breast irradiation technique called MammoSite® (Proxima Therapeutic Inc., Alpharetta, GA) has been advocated in recent years. In MammoSite, a balloon implanted at the surgical cavity during tumor excision is filled with a radio‐opaque solution, and radiation is delivered via a high dose rate brachytherapy source situated at the center of the balloon. Frequently air may be introduced during placement of the balloon and/or injection of the contrast solution into the balloon. The purpose of this work is to quantify as well as to understand dose perturbations due to the presence of a high‐Z contrast medium and/or an air bubble with measurements and Monte Carlo calculations. In addition, the measured dose distribution is compared with that obtained from a commercial treatment planning system (Nucletron PLATO system). For a balloon diameter of 42 mm, the dose variation as a function of distance from the balloon surface is measured for various concentrations of a radio‐opaque solution (in the range 5%–25% by volume) with a small volume parallel plate ion chamber and a micro‐diode detector placed perpendicular to the balloon axis. Monte Carlo simulations are performed to provide a basic understanding of the interaction mechanism and the magnitude of dose perturbation at the interface near balloon surface. Our results show that the radio‐opaque concentration produces dose perturbation up to 6%. The dose perturbation occurs mostly within the distances from the balloon surface. The Plato system that does not include heterogeneity correction may be sufficient for dose planning at distances from the balloon surface for the iodine concentrations used in the MammoSite procedures. The dose enhancement effect near the balloon surface due to the higher iodine concentration is not correctly predicted by the Plato system. The dose near the balloon surface may be increased by of air. Monte Carlo simulation suggests that the interface effect (enhanced dose near surface) is primarily due to Compton electrons of short range . For more accurate dosimetry in MammoSite delivery, the dose perturbation due to the presence of a radio‐opaque contrast medium and air bubbles should be considered in a brachytherapy planning system.


  • Beam characteristics of upper and lower physical wedge systems of Varian accelerators

    by Chee-Wai Cheng, Walter L Tang, Indra J Das

    The beam characteristics of a dual physical wedge system, upper and lower, for Varian accelerators are studied over the energy range 6–18 MV. Wedge factors for both systems are measured in a water phantom as a function of field size, depth and source-to-wedge (SWD) distance. Our results indicate that apart from their physical differences, dosimetrically, the two wedge systems have dmax, resulting in nearly 44% reduction in water phantom scanning and 80% reduction in point measurements during commissioning.


  • Dosimetric Evaluation and Clinical Application of Virtual Mini-Multileaf Collimator

    by C-W Cheng, J R. Wong, A M. Ndlovu, I J. Das, P Schiff, M Uematsu

    One of the major concerns with multileaf collimators (MLC) is the jagged field edge that produces a larger penumbra compared with that produced by a Cerrobend block. The dosimetric undulation of the MLC can be minimized by replacing an existing MLC with a mini-MLC, an expensive replacement, or by software implementation, which essentially converts a regular MLC into a virtual mini-MLC. In this study, the dosimetry in the penumbra region of a virtual mini-MLC replacing the Cerrobend block is investigated for clinical applications. HD270, a software program implemented by Siemens (Concord, CA), combines the use of an MLC and a table translation perpendicular to the leaf plane to produce a smooth field edge, thus reducing isodose undulation. Three different step resolutions are available: 5 mm, 3 mm, and 2 mm. Using film dosimetry, the penumbra regions are studied at two different depths for clinical blocks and corresponding MLC setup, as well as HD270 with different resolutions for both 6-MV and 15-MV x-ray beams. The dose delivery time for HD270 on auto-sequencing mode is compared with the use of Cerrobend blocks. The clinical applications of HD270 in head-and-neck (head and neck) and prostate treatments are investigated. For single-field irradiation, the 80-20% penumbra widths for both the 45 degrees block and the circular block are reduced with HD270 compared with MLC for both 6 and 15 MV at different depths. At 2-mm resolution, the scalloping isodose lines (IDLs) with MLC completely disappear, although the penumbra is still larger than the Cerrobend block. On the other hand, the difference in dose undulations between 2-mm and 3-mm resolution is small. In the head and neck irradiation, the 80-20% widths with HD270 are 1 to 2 mm less than MLC, but they are still 2 mm wider than with a Cerrobend block. The 50% IDL is reduced by 2 mm with HD270 compared with MLC, which provides safety near spinal cord. Dose-volume histogram (DVH) calculations for the different shielding techniques indicate that the HD270 improves the spinal cord dose distribution significantly compared with MLC. A similar improvement in dose undulation is observed for the prostate case. In the dose region, >60% of the prescribed dose, there is approximately 10% less irradiated volume for the rectum when HD270 (3 mm resolution) is employed compared with MLC. The treatment time was compared with that from the Cerrobend block, and it was found that even at 3-mm resolution, there is a 20% reduction in treatment time in a head and neck treatment; with a 2-mm resolution, there is a 15% increase in time. The isodose undulation due to MLC can be significantly reduced with the HD270. Clinical application with HD270 for head and neck and prostate irradiation provides a smaller penumbra region compared with MLC, although it still gives a larger one compared with the Cerrobend block. In the clinical cases presented in this study, the 3-mm resolution is the most effective in improving the penumbra and delivery time. The HD270 implementation is a versatile and cost-effective solution for reducing MLC undulation.


  • Commissioning and Clinical Implementation of a Sliding Gantry CT Scanner Installed in an Existing Treatment Room and Early Clinical Experience for Precise Tumor Localization

    by Chee-Wai Cheng, James Wong, Lisa Grimm, Michael Chow, Minoru Uematsu, Albert Fung

    The primary objective of the present study is to demonstrate that a unique computed tomography (CT)-linear accelerator combination can be used to reduce uncertainties caused by organ motion and setup inaccuracy. The acceptance, commissioning, and clinical implementation of a sliding gantry CT scanner installed in an existing linear accelerator room are reported in this paper. A Siemens CT scanner was installed directly opposite to an existing accelerator. The scanner is movable on a pair of horizontal rails mounted parallel to the longitudinal axis of the treatment couch replaced with a carbon fiber tabletop. Acceptance and commissioning of the CT scanner were verified with phantom studies. For clinical implementation, quality assurance (QA) procedures have been instituted to ensure the integrity of the CT gantry axis alignment and the accuracy of its movement using a phantom designed in house. A clinical example employing the CT-Linac combination to correct the isocenter positioning caused by organ motion and setup inaccuracy was presented for a prostate irradiation. Dose calculations were performed to study the effects on tumor coverage without the adjustments of the isocenter. A summary of the isocenter adjustments for the first 30 patients is also presented. The geometric accuracy of the CT scanner is < or =1 mm. An isocenter deviation of > or =2 mm from the original plan can be detected. For the clinical example of a prostate patient, the average movement of the prostate gland was found to be approximately 3mm in the anterior-posterior (AP/PA) direction and 5 mm in the cephalic-caudal direction. Variations in the isocenter position may result in underdosage of the PTV if correction is not made for the change in the isocenter position. Our experience with the first 30 patients indicates that while the left-right adjustment of the isocenter is minimal, in the AP/PA direction, about 33% of treatments required an adjustment of 3-5 mm, and about 18% required a 5.1-mm to 10-mm adjustment. In the caudal-cephalic direction, about 26% required an adjustment of 3-5 mm, and 8% required a 5.1-mm to 10-mm adjustment. Retrofitting a CT scanner in an existing linear accelerator room requires careful planning and well-coordinated efforts from all personnel involved. Special QA procedures are needed to ensure the mechanical integrity and imaging accuracy of the CT scanner. A CT scan of the patient prior to irradiation provides valuable information on organ motion. Any deviations from treatment plan can be corrected before dose delivery. Significant deviation from the planning isocenter may occur due to daily variations in the rectal filling. The CT-Linac combination has significant implications for the treatment of prostate cancer.


  • Suppression of dark current radiation in step‐and‐shoot intensity modulated radiation therapy by the initial pulse‐forming network

    by Chee‐Wai Cheng, Indra J. Das, Alois M. Ndlovu

    The effect of the initial pulse forming network (IPFN) on the suppression of dark current is investigated for a Siemens Primus accelerator. The dark current produces a spurious radiation, which is referred to as dark current radiation (DCR) in this study. In the step‐and‐shoot delivery of an intensity modulated radiation therapy (IMRT), the DCR could be of some concern for whole body dose along with leakage radiation through collimator jaws or multileaf collimator. By adjusting the IPFN‐to‐PFN ratio to >0.8, the DCR can be measured with an ion chamber during the “PAUSE” state of the accelerator in the IMRT mode. For 15 MV x rays, the magnitude of the DCR is approximately equal to 0.7% of the dose at for a field. The DCR has a similar central axis depth dose as a 15 MV beam as determined from a water phantom scan. When the IPFN‐to‐PFN ratio is lowered to <0.8, no DCR is detected. For low energy x rays (6 MV), no DCR is detected regardless of the IPFN‐to‐PFN ratio. Although the DCR is studied only for the Siemens Primus model accelerator, the same precaution applies to other models of modern accelerators from other vendors. Due to the large number of field segments used in a step‐and‐shoot IMRT, it is imperative therefore, that dark current evaluation be part of machine commissioning and annual calibration for high‐energy photon beams. Should DCR be detected, the medical physicist should work with a service engineer to rectify the problem. In view of DCR and whole body dose, low‐energy photon beams are advisable for IMRT.


  • Comparison of beam characteristics in intensity modulated radiation therapy (IMRT) and those under normal treatment condition

    by C.-W. Cheng, I. J. Das

    In the step-and-shoot delivery of an IMRT plan with a Siemens Primus accelerator, radiation is turned off by desynchronizing the injector while the field parameters are being changed. When the machine is ready again a trigger pulse is sent to the injector to start the beam instantaneously. The objective of this study is to investigate the beam characteristics of the machine operating in the IMRT mode and to study the effect of the Initial Pulse Forming Network (IPEN) on the dark current. The central axis (CAX) output for a 10 x 10 cm2 field over the range 1-100 MU was measured with an ion chamber in a polystyrene phantom for both 6 and 15 MV x rays. Beam profiles were also measured over the range of 2-40 MU with the machine operating in the IMRT mode and compared with those in the normal mode. By adjusting the IPFN value, dark current radiation (DCR) was measured using ion chamber measurements. For both the normal and IMRT modes, dose versus MU is nonlinear in the range 1-5 MUs. Above 5 MU, dose varies linearly with MU for both 6 and 15 MV x rays. For stability of dose profiles, the 2 MU-IM group exhibit 20% variation from one subfield to another. The variation is about 5% for the 8 MU-IM group and 80% of the PFN value, a spurious radiation associated with dark current at approximately 0.7% of the dose at isocenter for a 10 x 10 cm2 field is detected during the "PAUSE" state of the accelerator for 15 MV x rays. When the IPFN is lowered to <80% of the PFN value, no DCR is detected. For 6 MV x rays, no measurable DCR was detected regardless of the IPFN setting.


  • Open Access

    Role of multileaf collimator in replacing shielding blocks in radiation therapy.

    by Chee-Wai Cheng, Indra J. Das, Todd Steinberg