Christian Hauck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christian Hauck has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Daniel Vonder Mühll
Geographical Institute, University of Zurich, Switzerland
3 shared publicationsChristof Kneisel
Institute for Physical Geography, University of Würzburg, Germany
1 shared publication- Gonçalo Vieira
Centre of Geographical Studies, Associate Laboratory TERRA, Institute of Geography and Spatial Planning, University of Lisbon, Lisbon, Portugal
1 shared publication - Hansruedi Maurer
ETH Zurich
1 shared publication Johan Ludvig Sollid
Geographical Institute, University of Oslo, Norway
1 shared publication- Juan Jose Blanco
Universidad de Alcalà
1 shared publication
Latest Publications
- 21 June 2007
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Earth Surface
- Vol. 112 (F2)
Geophysical identification of permafrost in Livingston Island, maritime Antarctica
The current permafrost distribution on Livingston Island, South Shetland Islands, maritime Antarctic, was investigated using electrical resistivity tomography, refraction seismics, and shallow borehole temperatures. The field sites include different geological and geomorphological settings, including ice cored moraines and bedrock sites with debris covers of different thickness. Two‐dimensional geophysical inversion schemes were used to analyze spatial heterogeneity at field sites and to detect isolated occurrences of ground ice. Results confirm that permafrost is widespread on Livingston Island, with high ice content in ice cored moraines and little in the cracks and fissures of frozen bedrock. Specific electrical resistivity values range from 10,000–40,000 ohm‐m (frozen unconsolidated material) to 1500–10,000 ohm‐m (frozen quartzite/shale). Combining seismic P wave velocities and specific electrical resistivities, a typical “roof‐type” distribution was found with maximum resistivities coinciding with P wave velocities around 3000 m/s and decreasing resistivities for both increasing and decreasing velocities.
- 21 June 2007
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Earth Surface
- Vol. 112 (F2)
Geophysical identification of permafrost in Livingston Island, maritime Antarctica
The current permafrost distribution on Livingston Island, South Shetland Islands, maritime Antarctic, was investigated using electrical resistivity tomography, refraction seismics, and shallow borehole temperatures. The field sites include different geological and geomorphological settings, including ice cored moraines and bedrock sites with debris covers of different thickness. Two‐dimensional geophysical inversion schemes were used to analyze spatial heterogeneity at field sites and to detect isolated occurrences of ground ice. Results confirm that permafrost is widespread on Livingston Island, with high ice content in ice cored moraines and little in the cracks and fissures of frozen bedrock. Specific electrical resistivity values range from 10,000–40,000 ohm‐m (frozen unconsolidated material) to 1500–10,000 ohm‐m (frozen quartzite/shale). Combining seismic P wave velocities and specific electrical resistivities, a typical “roof‐type” distribution was found with maximum resistivities coinciding with P wave velocities around 3000 m/s and decreasing resistivities for both increasing and decreasing velocities.
- 1 April 2006
- Published by Wiley in Permafrost and Periglacial Processes
- Vol. 17 (2) , 169-177
Application of capacitively-coupled and DC electrical resistivity imaging for mountain permafrost studies
- 1 April 2006
- Published by Wiley in Permafrost and Periglacial Processes
- Vol. 17 (2) , 169-177
Application of capacitively-coupled and DC electrical resistivity imaging for mountain permafrost studies
- 1 July 2004
- Published by Wiley in Permafrost and Periglacial Processes
- Vol. 15 (3) , 191-205
Geophysical surveys designed to delineate the altitudinal limit of mountain permafrost: an example from Jotunheimen, Norway
Three geophysical methods have been applied to delineate the altitudinal limit of permafrost at Juvvasshøe/Jotunheimen in southern Norway. By using each method in a complementary way according to its applicability, the permafrost distribution could be analysed on both large and small scales. In addition, temperature‐based methods such as the BTS method (bottom temperature of snow cover) were used to validate the results. On a large scale, electromagnetic induction profiling with the EM‐31 was used to detect the location of the transition area between frozen and unfrozen ground. Within this area direct‐current (DC) resistivity and refraction seismic tomography were also applied to further characterize and visualize the permafrost transition. The large scale surveys revealed a sharp increase in conductivity, indicating an increase in unfrozen water content, near 1400 m a.s.l., with a possible transition zone between 1500 m a.s.l. and 1380 m a.s.l. The small scale investigation delineated the altitudinal limit of permafrost between 1470 m a.s.l. and 1410 m a.s.l., with sporadic ground ice occurrences and temperatures near the freezing point. Copyright © 2004 John Wiley & Sons, Ltd.
- 1 July 2004
- Published by Wiley in Permafrost and Periglacial Processes
- Vol. 15 (3) , 191-205
Geophysical surveys designed to delineate the altitudinal limit of mountain permafrost: an example from Jotunheimen, Norway
Three geophysical methods have been applied to delineate the altitudinal limit of permafrost at Juvvasshøe/Jotunheimen in southern Norway. By using each method in a complementary way according to its applicability, the permafrost distribution could be analysed on both large and small scales. In addition, temperature‐based methods such as the BTS method (bottom temperature of snow cover) were used to validate the results. On a large scale, electromagnetic induction profiling with the EM‐31 was used to detect the location of the transition area between frozen and unfrozen ground. Within this area direct‐current (DC) resistivity and refraction seismic tomography were also applied to further characterize and visualize the permafrost transition. The large scale surveys revealed a sharp increase in conductivity, indicating an increase in unfrozen water content, near 1400 m a.s.l., with a possible transition zone between 1500 m a.s.l. and 1380 m a.s.l. The small scale investigation delineated the altitudinal limit of permafrost between 1470 m a.s.l. and 1410 m a.s.l., with sporadic ground ice occurrences and temperatures near the freezing point. Copyright © 2004 John Wiley & Sons, Ltd.
- 1 October 2003
- Published by Wiley in Permafrost and Periglacial Processes
- Vol. 14 (4) , 305-318
Inversion and interpretation of two‐dimensional geoelectrical measurements for detecting permafrost in mountainous regions
The use of tomographic geoelectrical measurements for the detection of ground ice occurrences in mountainous regions is evaluated. Because isolated ground ice occurrences in a warming climate may be subject to rapid thawing, they present a future hazard in the context of thawing‐permafrost‐induced landslides and rockfalls. Isolated permafrost occurrences are difficult to detect with commonly used one‐dimensional sounding techniques, as plane‐layer approximations for the inversion are often invalid. Therefore, recently developed two‐dimensional tomographic inversion schemes are used to yield realistic near‐surface geological models. The method is applied to various types of permafrost occurrences in the European Alps. The influence of topography, measurement geometry and different inversion parameters are discussed. In addition, complimentary seismic survey results are used to exclude the possibility of air‐filled cavities, which exhibit similarly high resistivities as ground ice occurrences. The results show a large variety of influencing parameters which have to be considered in resistivity inversion and interpretation. Copyright © 2003 John Wiley & Sons, Ltd.
- 1 October 2003
- Published by Wiley in Permafrost and Periglacial Processes
- Vol. 14 (4) , 305-318
Inversion and interpretation of two‐dimensional geoelectrical measurements for detecting permafrost in mountainous regions
The use of tomographic geoelectrical measurements for the detection of ground ice occurrences in mountainous regions is evaluated. Because isolated ground ice occurrences in a warming climate may be subject to rapid thawing, they present a future hazard in the context of thawing‐permafrost‐induced landslides and rockfalls. Isolated permafrost occurrences are difficult to detect with commonly used one‐dimensional sounding techniques, as plane‐layer approximations for the inversion are often invalid. Therefore, recently developed two‐dimensional tomographic inversion schemes are used to yield realistic near‐surface geological models. The method is applied to various types of permafrost occurrences in the European Alps. The influence of topography, measurement geometry and different inversion parameters are discussed. In addition, complimentary seismic survey results are used to exclude the possibility of air‐filled cavities, which exhibit similarly high resistivities as ground ice occurrences. The results show a large variety of influencing parameters which have to be considered in resistivity inversion and interpretation. Copyright © 2003 John Wiley & Sons, Ltd.
- 18 July 2003
- Published by Wiley in Geophysical Prospecting
- Vol. 51 (4) , 273-284
Using DC resistivity tomography to detect and characterize mountain permafrost
Direct‐current (DC) resistivity tomography has been applied to different mountain permafrost regions. Despite problems with the very high resistivities of the frozen material, plausible results were obtained. Inversions with synthetic data revealed that an appropriate choice of regularization constraints was important, and that a joint analysis of several tomograms computed with different constraints was required to judge the reliability of individual features. The theoretical results were verified with three field experiments conducted in the Swiss and the Italian Alps. At the first site, near Zermatt, Switzerland, the location and the approximate lateral and vertical extent of an ice core within a moraine could be delineated. On the Murtel rock glacier, eastern Swiss Alps, a steeply dipping boundary at its frontal part was observed, and extremely high resistivities of several MΩ indicated a high ice content. The base of the rock glacier remained unresolved by the DC resistivity measurements, but it could be constrained with transient EM soundings. On another rock glacier near the Stelvio Pass, eastern Italian Alps, DC resistivity tomography allowed delineation of the rock glacier base, and the only moderately high resistivities within the rock glacier body indicated that the ice content must be lower compared with the Murtel rock glacier.
- 18 July 2003
- Published by Wiley in Geophysical Prospecting
- Vol. 51 (4) , 273-284
Using DC resistivity tomography to detect and characterize mountain permafrost
Direct‐current (DC) resistivity tomography has been applied to different mountain permafrost regions. Despite problems with the very high resistivities of the frozen material, plausible results were obtained. Inversions with synthetic data revealed that an appropriate choice of regularization constraints was important, and that a joint analysis of several tomograms computed with different constraints was required to judge the reliability of individual features. The theoretical results were verified with three field experiments conducted in the Swiss and the Italian Alps. At the first site, near Zermatt, Switzerland, the location and the approximate lateral and vertical extent of an ice core within a moraine could be delineated. On the Murtel rock glacier, eastern Swiss Alps, a steeply dipping boundary at its frontal part was observed, and extremely high resistivities of several MΩ indicated a high ice content. The base of the rock glacier remained unresolved by the DC resistivity measurements, but it could be constrained with transient EM soundings. On another rock glacier near the Stelvio Pass, eastern Italian Alps, DC resistivity tomography allowed delineation of the rock glacier base, and the only moderately high resistivities within the rock glacier body indicated that the ice content must be lower compared with the Murtel rock glacier.