Marc D. Porter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marc D. Porter has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jeremy D. Driskell
Department of Chemistry
2 shared publications - Julia F. Ridpath
Ruminant Disease and Immunology Research Unit, National Animal Disease Center, USDA, Agricultural Research Service, Ames, IA 50010, United States
2 shared publications Ann Vorwald
1 shared publicationAnthony Popple
NVE Corporation, Eden Prairie, Minnesota 55344, USA
1 shared publicationApril A. Hill
Materials Science and Engineering Center, The Pennsylvania State University, University Park, Pennsylvania 16802
1 shared publicationBikas Vaidya
Microanalytical Instrumentation Center, Ames Laboratory-USDOE and Department of Chemistry, Iowa State University, AmesIA 50011USA
1 shared publication
Latest Publications
- 1 June 2010
- Published by Annual Reviews in Annual Review of Analytical Chemistry
- Vol. 3 (1) , 387-407
Rotationally Induced Hydrodynamics: Fundamentals and Applications to High-Speed Bioassays
Bioassays are indispensable tools in areas ranging from fundamental life science research to clinical practice. Improving assay speed and levels of detection will have a profound impact in all of these areas. We recently developed a rapid, sensitive format for immunosorbent assays that expedites antigen mass transport by rotating the capture substrate. This review outlines the theoretical foundation of rotationally induced hydrodynamics and its application in heterogeneous assays. We describe a general solution that solves the rates of immunoreactions on rotating capture substrates, taking into account both diffusion and the rate of reaction between antibody and antigen. The general solution applies to a wide range of rotation rates, including mass transport–limited to reaction rate–limited assays, and is validated experimentally. We discuss several applications that demonstrate how immunoassays can be tailored to increase speed as well as lower the limit of detection of viral particles, pathogens, toxins, and proteins.
- 1 June 2010
- Published by Annual Reviews in Annual Review of Analytical Chemistry
- Vol. 3 (1) , 387-407
Rotationally Induced Hydrodynamics: Fundamentals and Applications to High-Speed Bioassays
Bioassays are indispensable tools in areas ranging from fundamental life science research to clinical practice. Improving assay speed and levels of detection will have a profound impact in all of these areas. We recently developed a rapid, sensitive format for immunosorbent assays that expedites antigen mass transport by rotating the capture substrate. This review outlines the theoretical foundation of rotationally induced hydrodynamics and its application in heterogeneous assays. We describe a general solution that solves the rates of immunoreactions on rotating capture substrates, taking into account both diffusion and the rate of reaction between antibody and antigen. The general solution applies to a wide range of rotation rates, including mass transport–limited to reaction rate–limited assays, and is validated experimentally. We discuss several applications that demonstrate how immunoassays can be tailored to increase speed as well as lower the limit of detection of viral particles, pathogens, toxins, and proteins.
- 1 January 2006
- Vol. 126, 31
Detection of viruses: atomic force microscopy and surface enhanced Raman spectroscopy.
This paper demonstrates the capability of atomic force microscopy (AFM) and surface enhanced Raman spectroscopy (SERS) to function effectively as ultra-sensitive readout tools for chip-scale platforms designed for pathogen detection in complex biological media. AFM allows direct (i.e., label-free) visualization and quantification of nanometer-sized viruses captured on a smooth, selective surface. AFM readout led to optimization of a capture substrate for feline calicivirus (FCV), and yielded a limit of detection of 3 x 10(6) FCV/mL. SERS-based detection of FCV, carried out in a sandwich-type assay, requires labelling of the substrate-bound FCV with a selective extrinsic Raman label (ERL). These studies yielded a limit of detection of 1 x 10(6) FCV/mL. The prospects of these two readout methods as additions to the arsenal of tools in bioterrorism prevention are briefly discussed.
- 1 January 2006
- Vol. 126, 31
Detection of viruses: atomic force microscopy and surface enhanced Raman spectroscopy.
This paper demonstrates the capability of atomic force microscopy (AFM) and surface enhanced Raman spectroscopy (SERS) to function effectively as ultra-sensitive readout tools for chip-scale platforms designed for pathogen detection in complex biological media. AFM allows direct (i.e., label-free) visualization and quantification of nanometer-sized viruses captured on a smooth, selective surface. AFM readout led to optimization of a capture substrate for feline calicivirus (FCV), and yielded a limit of detection of 3 x 10(6) FCV/mL. SERS-based detection of FCV, carried out in a sandwich-type assay, requires labelling of the substrate-bound FCV with a selective extrinsic Raman label (ERL). These studies yielded a limit of detection of 1 x 10(6) FCV/mL. The prospects of these two readout methods as additions to the arsenal of tools in bioterrorism prevention are briefly discussed.
- 3 March 2005
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 293 (1) , 584-588
Magnetic particle diverter in an integrated microfluidic format
- 3 March 2005
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 293 (1) , 584-588
Magnetic particle diverter in an integrated microfluidic format
- 31 August 2004
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (19) , 5823-5828
High-Speed Electrochemically Modulated Liquid Chromatography
The performance advantages of carrying out electrochemically modulated liquid chromatography (EMLC) at elevated temperatures and mobile-phase flow rates are investigated. EMLC has the unique ability to manipulate analyte retention and enhance separation efficiencies through changes in the potential applied to a conductive stationary phase. Operation of high-performance liquid chromatography systems at elevated column temperatures also provides pathways to improve chromatographic performance by enhancing analyte diffusivity and facilitating the use of higher mobile-phase flow rates than conventionally attainable. The results show that performing EMLC separations at elevated temperatures (e.g., 100 °C) reduces the analysis time of a mixture of aromatic sulfonates in a mixed mobile phase by more than a factor of 20. Moreover, use of higher operating temperatures enables the separation of this mixture with an entirely aqueous mobile phase in less than 2 min.
- 31 August 2004
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (19) , 5823-5828
High-Speed Electrochemically Modulated Liquid Chromatography
The performance advantages of carrying out electrochemically modulated liquid chromatography (EMLC) at elevated temperatures and mobile-phase flow rates are investigated. EMLC has the unique ability to manipulate analyte retention and enhance separation efficiencies through changes in the potential applied to a conductive stationary phase. Operation of high-performance liquid chromatography systems at elevated column temperatures also provides pathways to improve chromatographic performance by enhancing analyte diffusivity and facilitating the use of higher mobile-phase flow rates than conventionally attainable. The results show that performing EMLC separations at elevated temperatures (e.g., 100 °C) reduces the analysis time of a mixture of aromatic sulfonates in a mixed mobile phase by more than a factor of 20. Moreover, use of higher operating temperatures enables the separation of this mixture with an entirely aqueous mobile phase in less than 2 min.
- 22 October 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (11) , 1841-1849
Electrochemically modulated liquid chromatography: an electrochemical strategy for manipulating chromatographic retention
- 22 October 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (11) , 1841-1849
Electrochemically modulated liquid chromatography: an electrochemical strategy for manipulating chromatographic retention
- 18 December 1998
- Published by Elsevier in Journal of Chromatography A
- Vol. 828 (1-2) , 157-166
Enantiomeric separations of benzodiazepines by electrochemically modulated liquid chromatography
- 18 December 1998
- Published by Elsevier in Journal of Chromatography A
- Vol. 828 (1-2) , 157-166
Enantiomeric separations of benzodiazepines by electrochemically modulated liquid chromatography
- 30 December 1997
- Published by Elsevier in Analytica Chimica Acta
- Vol. 357 (1-2) , 167-175
Reduction of chloride ion interference in chemical oxygen demand (COD) determinations using bismuth-based adsorbents
- 30 December 1997
- Published by Elsevier in Analytica Chimica Acta
- Vol. 357 (1-2) , 167-175
Reduction of chloride ion interference in chemical oxygen demand (COD) determinations using bismuth-based adsorbents
- 26 March 1997
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 425 (1-2) , 147-153
Fine structure in the voltammetric desorption curves of alkanethiolate monolayers chemisorbed at gold
- 26 March 1997
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 425 (1-2) , 147-153
Fine structure in the voltammetric desorption curves of alkanethiolate monolayers chemisorbed at gold