S P M Crijns
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
S P M Crijns has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
J.J.W. Lagendijk
6 shared publications- Bas W. Raaymakers
Department of Radiotherapy, University Medical Center Utrecht, the Netherlands
5 shared publications B W Raaymakers
4 shared publicationsJ J W Lagendijk
4 shared publicationsM.K. Stam
2 shared publicationsB. Raaymakers
1 shared publication
Latest Publications
- Open Access
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S130-S131
OC-0257: Comprehensive MRI Acceptance Testing & Commissioning of a 1.5T MR-Linac: Guidelines and Results
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S130-S131
Open AccessOC-0257: Comprehensive MRI Acceptance Testing & Commissioning of a 1.5T MR-Linac: Guidelines and Results
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S249
SP-0650: Sequences for MRI guided external beam RT
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S249
Open AccessSP-0650: Sequences for MRI guided external beam RT
- Open Access
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S156-S157
PD-0408: Upgrading the MRI-linac prototype to a gantry-based system: impact on magnetic field homogeneity
- 1 March 2013
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 106, S156-S157
Open AccessPD-0408: Upgrading the MRI-linac prototype to a gantry-based system: impact on magnetic field homogeneity
- 14 November 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (23) , 7863-7872
Proof of concept of MRI-guided tracked radiation delivery: tracking one-dimensional motion
In radiotherapy one aims to deliver a radiation dose to a tumour with high geometrical accuracy while sparing organs at risk (OARs). Although image guidance decreases geometrical uncertainties, treatment of cancer of abdominal organs is further complicated by respiratory motion, requiring intra-fraction motion compensation to fulfil the treatment intent. With an ideal delivery system, the optimal method of intra-fraction motion compensation is to adapt the beam collimation to the moving target using a dynamic multi-leaf collimator (MLC) aperture. The many guidance strategies for such tracked radiation delivery tested up to now mainly use markers and are therefore invasive and cannot deal with target deformations or adaptations for OAR positions. We propose to address these shortcomings using the online MRI guidance provided by an MRI accelerator and present a first step towards demonstration of the technical feasibility of this proposal. The position of a phantom subjected to one-dimensional (1D) periodic translation was tracked using a fast 1D MR sequence. Real-time communication with the MR scanner and control of the MLC aperture were established. Based on the time-resolved position of the phantom, tracked radiation delivery to the phantom was realized. Dose distributions for various delivery conditions were recorded on a gafchromic film. Without motion a sharply defined dose distribution is obtained, whereas considerable blur occurs for delivery to a moving phantom. With compensation for motion, the sharpness of the dose distribution is nearly restored. The total latency in our motion management architecture is approximately 200 ms. Combination of the recorded phantom and aperture positions with the planned dose distribution enabled the reconstruction of the delivered dose in all cases, which illustrates the promise of online dose accumulation and confirms that latency compensation could further enhance our results. For a simple 1D tracked delivery scenario, the technical feasibility of MRI-guided tracked radiation delivery is confirmed. More generic tracking scenarios require advanced MRI, leading to increased acquisition time and more challenging image processing problems. Latency compensation is therefore an important subject of future investigations.
- 14 November 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (23) , 7863-7872
Proof of concept of MRI-guided tracked radiation delivery: tracking one-dimensional motion
In radiotherapy one aims to deliver a radiation dose to a tumour with high geometrical accuracy while sparing organs at risk (OARs). Although image guidance decreases geometrical uncertainties, treatment of cancer of abdominal organs is further complicated by respiratory motion, requiring intra-fraction motion compensation to fulfil the treatment intent. With an ideal delivery system, the optimal method of intra-fraction motion compensation is to adapt the beam collimation to the moving target using a dynamic multi-leaf collimator (MLC) aperture. The many guidance strategies for such tracked radiation delivery tested up to now mainly use markers and are therefore invasive and cannot deal with target deformations or adaptations for OAR positions. We propose to address these shortcomings using the online MRI guidance provided by an MRI accelerator and present a first step towards demonstration of the technical feasibility of this proposal. The position of a phantom subjected to one-dimensional (1D) periodic translation was tracked using a fast 1D MR sequence. Real-time communication with the MR scanner and control of the MLC aperture were established. Based on the time-resolved position of the phantom, tracked radiation delivery to the phantom was realized. Dose distributions for various delivery conditions were recorded on a gafchromic film. Without motion a sharply defined dose distribution is obtained, whereas considerable blur occurs for delivery to a moving phantom. With compensation for motion, the sharpness of the dose distribution is nearly restored. The total latency in our motion management architecture is approximately 200 ms. Combination of the recorded phantom and aperture positions with the planned dose distribution enabled the reconstruction of the delivered dose in all cases, which illustrates the promise of online dose accumulation and confirms that latency compensation could further enhance our results. For a simple 1D tracked delivery scenario, the technical feasibility of MRI-guided tracked radiation delivery is confirmed. More generic tracking scenarios require advanced MRI, leading to increased acquisition time and more challenging image processing problems. Latency compensation is therefore an important subject of future investigations.
- 1 May 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 103, S170
SP-0427 DOSIMETRY IN STRONG MAGNETIC FIELDS; ISSUES AND OPPORTUNITIES
- 1 May 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 103, S170
SP-0427 DOSIMETRY IN STRONG MAGNETIC FIELDS; ISSUES AND OPPORTUNITIES
- 1 May 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 103, S8
OC-0023 GATED MRI-LINAC (MRL) TREATMENT FOR KIDNEYS: INTER BREATH HOLD VARIATIONS
- 1 May 2012
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 103, S8
OC-0023 GATED MRI-LINAC (MRL) TREATMENT FOR KIDNEYS: INTER BREATH HOLD VARIATIONS
- 21 February 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (5) , 1349-1358
Towards inherently distortion-free MR images for image-guided radiotherapy on an MRI accelerator
In MR-guided interventions, it is mandatory to establish a solid relationship between the imaging coordinate system and world coordinates. This is particularly important in image-guided radiotherapy (IGRT) on an MRI accelerator, as the interaction of matter with γ-radiation cannot be visualized. In conventional acquisitions, off-resonance effects cause discrepancies between coordinate systems. We propose to mitigate this by using only phase encoding and to reduce the longer acquisitions by under-sampling and regularized reconstruction. To illustrate the performance of this acquisition in the presence of off-resonance phenomena, phantom and in vivo images are acquired using spin-echo (SE) and purely phase-encoded sequences. Data are retrospectively under-sampled and reconstructed iteratively. We observe accurate geometries in purely phase-encoded images for all cases, whereas SE images of the same phantoms display image distortions. Regularized reconstruction yields accurate phantom images under high acceleration factors. In vivo images were reconstructed faithfully while using acceleration factors up to 4. With the proposed technique, inherently undistorted images with one-to-one correspondence to world coordinates can be obtained. It is a valuable tool in geometry quality assurance, treatment planning and online image guidance. Under-sampled acquisition combined with regularized reconstruction can be used to accelerate the acquisition while retaining geometrical accuracy.
- 21 February 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (5) , 1349-1358
Towards inherently distortion-free MR images for image-guided radiotherapy on an MRI accelerator
In MR-guided interventions, it is mandatory to establish a solid relationship between the imaging coordinate system and world coordinates. This is particularly important in image-guided radiotherapy (IGRT) on an MRI accelerator, as the interaction of matter with γ-radiation cannot be visualized. In conventional acquisitions, off-resonance effects cause discrepancies between coordinate systems. We propose to mitigate this by using only phase encoding and to reduce the longer acquisitions by under-sampling and regularized reconstruction. To illustrate the performance of this acquisition in the presence of off-resonance phenomena, phantom and in vivo images are acquired using spin-echo (SE) and purely phase-encoded sequences. Data are retrospectively under-sampled and reconstructed iteratively. We observe accurate geometries in purely phase-encoded images for all cases, whereas SE images of the same phantoms display image distortions. Regularized reconstruction yields accurate phantom images under high acceleration factors. In vivo images were reconstructed faithfully while using acceleration factors up to 4. With the proposed technique, inherently undistorted images with one-to-one correspondence to world coordinates can be obtained. It is a valuable tool in geometry quality assurance, treatment planning and online image guidance. Under-sampled acquisition combined with regularized reconstruction can be used to accelerate the acquisition while retaining geometrical accuracy.
- 1 October 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 81 (2) , S30-S31
Navigators for Motion Detection in the 1.5T MRI-linac
- 1 October 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 81 (2) , S30-S31
Navigators for Motion Detection in the 1.5T MRI-linac
- 13 July 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (15) , 4815-4825
Towards MRI-guided linear accelerator control: gating on an MRI accelerator
To boost the possibilities of image guidance in radiotherapy by providing images with superior soft-tissue contrast during treatment, we pursue diagnostic quality MRI functionality integrated with a linear accelerator. Large respiration-induced semi-periodic target excursions hamper treatment of cancer of the abdominal organs. Methods to compensate in real time for such motion are gating and tracking. These strategies are most effective in cases where anatomic motion can be visualized directly, which supports the use of an integrated MRI accelerator. We establish here an infrastructure needed to realize gated radiation delivery based on MR feedback and demonstrate its potential as a first step towards more advanced image guidance techniques. The position of a phantom subjected to one-dimensional periodic translation is tracked with the MR scanner. Real-time communication with the MR scanner and control of the radiation beam are established. Based on the time-resolved position of the phantom, gated radiation delivery to the phantom is realized. Dose distributions for dynamic delivery conditions with varying gating windows are recorded on gafchromic film. The similarity between dynamically and statically obtained dose profiles gradually increases as the gating window is decreased. With gating windows of 5 mm, we obtain sharp dose profiles. We validate our gating implementation by comparing measured dose profiles to theoretical profiles calculated using the knowledge of the imposed motion pattern. Excellent correspondence is observed. At the same time, we show that real-time on-line reconstruction of the accumulated dose can be performed using time-resolved target position information. This facilitates plan adaptation not only on a fraction-to-fraction scale but also during one fraction, which is especially valuable in highly accelerated treatment strategies. With the currently established framework and upcoming improvements to our prototype-integrated MRI accelerator, we will realize more intricate MRI-guided linear accelerator control in the near future.
- 13 July 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (15) , 4815-4825
Towards MRI-guided linear accelerator control: gating on an MRI accelerator
To boost the possibilities of image guidance in radiotherapy by providing images with superior soft-tissue contrast during treatment, we pursue diagnostic quality MRI functionality integrated with a linear accelerator. Large respiration-induced semi-periodic target excursions hamper treatment of cancer of the abdominal organs. Methods to compensate in real time for such motion are gating and tracking. These strategies are most effective in cases where anatomic motion can be visualized directly, which supports the use of an integrated MRI accelerator. We establish here an infrastructure needed to realize gated radiation delivery based on MR feedback and demonstrate its potential as a first step towards more advanced image guidance techniques. The position of a phantom subjected to one-dimensional periodic translation is tracked with the MR scanner. Real-time communication with the MR scanner and control of the radiation beam are established. Based on the time-resolved position of the phantom, gated radiation delivery to the phantom is realized. Dose distributions for dynamic delivery conditions with varying gating windows are recorded on gafchromic film. The similarity between dynamically and statically obtained dose profiles gradually increases as the gating window is decreased. With gating windows of 5 mm, we obtain sharp dose profiles. We validate our gating implementation by comparing measured dose profiles to theoretical profiles calculated using the knowledge of the imposed motion pattern. Excellent correspondence is observed. At the same time, we show that real-time on-line reconstruction of the accumulated dose can be performed using time-resolved target position information. This facilitates plan adaptation not only on a fraction-to-fraction scale but also during one fraction, which is especially valuable in highly accelerated treatment strategies. With the currently established framework and upcoming improvements to our prototype-integrated MRI accelerator, we will realize more intricate MRI-guided linear accelerator control in the near future.
- 9 December 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (1) , 289-297
Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapy
Image-guided radiotherapy has the potential to increase the success of treatment by decreasing uncertainties concerning tumour position and shape. We pursue integrated diagnostic quality MRI functionality with radiotherapy systems to boost the possibilities of image guidance by providing images with superior soft-tissue contrast during treatment. However, the use of MR images in radiotherapy can be hindered by geometrical distortions due to magnetic field inhomogeneity problems. A method for fast correction of these distortions is presented and implemented. Using a 20 cm square phantom containing a regular grid, a measure of residual deformation after correction is established. At very low gradient strength (which leads to large deformations) a maximum displacement of 2.9 mm is shown to be reduced to 0.63 mm. Next, the method is applied in vivo to the case of pelvic body contour extraction for prostate radiotherapy treatment planning. Here, again with low gradient strengths, distortions of up to 6 mm can be reduced to 2 mm. All results are provided within a lag time of 8 ms. We discuss implications of image distortions for MRI-guided photon and proton radiotherapy separately, since the dose-depth curves in these treatments are very different. We argue that, although field inhomogeneities cannot be prevented from occurring, distortion correction is not always necessary in practice. This work opens new possibilities for investigating on-line MRI-based plan adaptations and ultimately MRI-based treatment planning.
- 9 December 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (1) , 289-297
Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapy
Image-guided radiotherapy has the potential to increase the success of treatment by decreasing uncertainties concerning tumour position and shape. We pursue integrated diagnostic quality MRI functionality with radiotherapy systems to boost the possibilities of image guidance by providing images with superior soft-tissue contrast during treatment. However, the use of MR images in radiotherapy can be hindered by geometrical distortions due to magnetic field inhomogeneity problems. A method for fast correction of these distortions is presented and implemented. Using a 20 cm square phantom containing a regular grid, a measure of residual deformation after correction is established. At very low gradient strength (which leads to large deformations) a maximum displacement of 2.9 mm is shown to be reduced to 0.63 mm. Next, the method is applied in vivo to the case of pelvic body contour extraction for prostate radiotherapy treatment planning. Here, again with low gradient strengths, distortions of up to 6 mm can be reduced to 2 mm. All results are provided within a lag time of 8 ms. We discuss implications of image distortions for MRI-guided photon and proton radiotherapy separately, since the dose-depth curves in these treatments are very different. We argue that, although field inhomogeneities cannot be prevented from occurring, distortion correction is not always necessary in practice. This work opens new possibilities for investigating on-line MRI-based plan adaptations and ultimately MRI-based treatment planning.