CZCatharina Zantner

Catharina Zantner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Catharina Zantner has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Andrej Michael Kielbassa

    Danube Private Univ DPU, Univ Sch Dent Med & Oral Hlth, Dept Operat Dent Periodontol & Endodontol, Krems, Austria

    6 shared publications
  • Konrad Neumann

    2 shared publications
  • Tania Schink

    Department of Clinical Epidemiology, Leibniz Institute for Prevention Research and Epidemiology – BIPS, Bremen, Germany

    2 shared publications
  • F. Derdilopoulou

    Foteini Derdilopoulou, Department of Operative Dentistry and Periodontology, University School of Dental Medicine, Campus Benjamin Franklin, Charité—Universitätsmedizin Berlin, Berlin, Germany

    1 shared publication
  • Foteini Derdilopoulou

    1 shared publication
  • Foteini V Derdilopoulou

    Department of Operative Dentistry and Periodontology, University School of Dental Medicine, Campus Benjamin Franklin, Charité-Universitätsmedizin Berlin, Germany

    1 shared publication

Latest Publications

    • 19 August 2007
      • Vol. 20  (4) , 414-6

    Evaluation of visual and spectrophotometric shade analyses: a clinical comparison of 3758 teeth.

    by Foteini V Derdilopoulou, Catharina Zantner, Konrad Neumann, Andrej M Kielbassa

    This study aimed to evaluate the performance of visual and spectrophotometric tooth shade analysis. Two operators independently selected the best match of 3758 anterior teeth of 106 patients at 3 different dates, using the Chromascop-Complete shade guide. Additionally, tooth color was analyzed 3 consecutive times using a reflectance spectrophotometer. Spectrophotometry showed high agreement values (89.6%); both examiners agreed in 49.7% of the measurements. Visual assessment resulted in significantly darker ratings than spectrophotometry (P < .0005). However, a positive association was observed for both procedures (P = .548). Spectrophotometric shade determination seems to be significantly more reproducible than the visual procedure.


  • Surface microhardness of enamel after different home bleaching procedures

    by Catharina Zantner, Nils Beheim-Schwarzbach, Konrad Neumann, Andrej M. Kielbassa


    • 1 October 2006
      • Vol. 37  (9) , 695-706

    Randomized clinical trial on the efficacy of 2 over-the-counter whitening systems.

    by Catharina Zantner, Foteini Derdilopoulou, Peter Martus, Andrej M Kielbassa

    The purpose of this clinical trial was to evaluate the efficacy of 2 over-the-counter whitening systems: a liquid whitening gel (5.9% hydrogen peroxide, twice a day for 15 minutes), and a sodium chlorite-based whitening gel applied in a tray system (10 minutes twice a day). Sixty volunteers (minimum shade A3 on 1 maxillary tooth) were selected to participate in this single-blind (examiner-blinded), single-center, 2-group trial. The subjects were randomly divided into 2 groups (n = 30 each) and instructed to bleach their teeth for 2 weeks. Efficacy was measured using the Vita Classical shade guide and a spectrophotometer at baseline, as well as after 2 weeks and 6 months. For the subjectively measured tooth shades, improvement for maxillary canines was 2.03 +/- 3.67 tooth shades in group 1 and 1.08 +/- 2.19 tooth shades in group 2 after 2 weeks; the maxillary incisors revealed a tooth shade improvement of 0.83 +/- 1.71 tabs in group 1 and 0.73 +/- 2.22 tabs in group 2 (P < .05, except maxillary incisors in group 2; t test). Objectively measured tooth shade scores revealed a change of 0 +/- 0.25 tooth shade tabs (P > .05). The bleaching gel containing hydrogen peroxide achieved a slight improvement, and the sodium chlorite-based bleaching gel achieved only a small tooth color improvement. Moreover, subjectively and objectively measured tooth shades revealed considerably different results in the clinical situation.


  • Randomized Clinical Trial on the Efficacy of a New Bleaching Lacquer for Self-application

    by C. Zantner, F. Derdilopoulou, P. Martus, A. M. Kielbassa

    SUMMARY: Background: This study evaluated the clinical efficacy and duration of effectiveness of a new bleaching lacquer for self-application without the use of mouth guards. It compared two different application times. Methods: Forty-six adult subjects who requested bleaching treatment were selected to participate in this randomized, single-blind (examiner-blinded), single center, two-group trial. The subjects were randomly divided into two groups (n=23 each), each being instructed to bleach (8% carbamide peroxide) their six maxillary anterior teeth for two weeks. Daily contact time in Group 1 was 20 minutes once a day and, in Group 2, the time was 20 minutes twice a day. Efficacy was measured subjectively using the Chromascop Complete shade scores obtained at baseline and after one, two and three weeks, as well as after one, three, six and nine months. Results: After two weeks of treatment, the teeth in the Group 1 subjects exhibited a 2.4 ± 0.2 mean shade scores improvement compared to baseline (p<0.001; t-test for paired samples), and the subjects' teeth in Group 2 exhibited a 3.5 ± 0.1 mean shade scores improvement (p0.05). The observed effects were stable for six months. Conclusions: It can be concluded that the new bleaching lacquer is efficacious; however, a double application does not seem to be obligatory.


    • 1 January 2006
      • Vol. 116  (12) , 1232-7

    Randomized clinical study on the efficacy of a new lacquer for dentine hypersensitivity.

    by Catharina Zantner, Odile Popescu, Peter Martus, Andrej M Kielbassa

    The purpose of this randomized, clinical, double-blind short-term trial was to evaluate the efficacy of a new lacquer containing a new component (phosphonic acid methacrylate) designed for treating dentine hypersensitivity. Eighty-eight patients participated in this study. At the first visit one tooth was treated with the lacquer (1), while another tooth was treated with a placebo (2). Sensitivity levels were determined before treatment as well as after one week. An air blast stimulus and a visual analogue scale were used for evaluation. At baseline, the mean hypersensitivity score of group 1 (53.2+/-26.3) was comparable to the mean hypersensitivity score of the teeth in group 2 (53.3+/-24.4). After one week, a significant reduction of the mean hypersensitivity scores (p <0.001; t-test) was revealed in group 1 (25.8 +/-26.6) as well as in group 2 (26.4+/-25.3). The difference between the two treatment groups was not significant (p = 0.7). There is either no difference between the two treatment modalities or the placebo response and/or the time effect was so strong that the treatment efficacy of the new lacquer was hidden by these effects.


  • Clinical monitoring of the effect of fluorides on long-existing white spot lesions

    by Catharina Zantner, Peter Martus, Andrej M. Kielbassa

    The aim of this examiner-blind, clinical monitoring was to observe long-existing white spot lesions over a period of 6[A1] months and to evaluate the effectiveness of fluoridated toothpastes on these lesions. Thirty-nine subjects with at least one lesion participated in the study. They were randomly divided into two groups (n=20 and n=19) and instructed to brush their teeth either with toothpaste containing sodium fluoride (1500 ppm) (group 1) or with toothpaste containing amine fluoride (1250 ppm) (group 2). Lesions were measured with quantitative light-induced fluorescence (QLF) and alterations were quantified by ▵Q as fluorescence loss integrated over the lesion area (%×mm2). All QLF images were taken by one examiner at baseline (▵Q1) and follow-up visits after 2, 4, 6, 8, 10, and 12 weeks, and after 4, 5, and 6 months (▵Q10). The results showed a slight but not significant progression of ▵Q (%×mm2) in group 1 ((p>0.05; t-test), ▵Q1 −20.31 (±41.06); ▵Q10 −26.2 (±47.69)) and in group 2 ((p>0.05), ▵Q1 −22.28 (±43.86); ▵Q10 −26.39 (±46.4)). The results indicated no significant differences regarding the influence of the fluoridated toothpastes (p>0.05). It can be concluded that within 6 months the long-existing white spot lesions are stable concerning fluorescence loss over the lesion area. Moreover, fluoride does not seem to have any effect on long-existing white spot lesions.