UBUlrich Beschorner

Ulrich Beschorner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ulrich Beschorner has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 August 2014
      • Vol. 55  (4) , 473-476

    Value of covered stents to improve patency of long-segment SFA revascularization

    by U. Beschorner, T. Zeller

    Endovascular treatment has become first-line approach for revascularization of long and complex femoropopliteal lesions in many centers. This development urges the need for endovascular approaches with a sustainable success in terms of potency. In several recently published trials the Viabahn (R) endoprosthesis by Gore (W.L. Gore Inc, Flagstaff, AZ, USA) has shown promising potency rates comparable or even better than traditional surgical bypass procedures with prosthetic material.

  • Rotational and aspiration atherectomy for infrainguinal in-stent restenosis

    by Ulrich Beschorner, Hans Krankenberg, Dierk Scheinert, Horst Sievert, Thilo Tübler, Sebastian Sixt, Elias Noory, Aljoscha Rastan, Roland Macharzina, Thomas Zeller

    Background: To report feasibility and safety of the Pathway PV™ Atherectomy System during percutaneous peripheral vascular interventions of in-stent restenosis. Patients and methods: 33 patients (66.7 % men; mean age 68.7 years; 39.4 % diabetics) with symptomatic infrainguinal in-stent restenosis were enrolled at 5 study sites. Primary study endpoint was the 30-day serious adverse event (SAE) rate. At one study site a subgroup of 13 patients was scheduled for additional follow-up examinations with duplex Results: Forty lesions with a mean lesion length of 85.7 mm (range 6 - 370 mm) were treated including total occlusions (20 %) and infrapopliteal lesions (5 %). In sixteen target lesions (40 %) procedural success was reached with atherectomy alone, 23 lesions (57.5 %) received adjunctive percutaneous transluminal angioplasty to obtain a sufficient angiographic result. Freedom from device-related SAEs was 100 %. Overall there were 11 unexpected adverse events in 11 patients, two of which were serious (retroperitoneal bleeding and access site infection). The ankle-brachial index increased significantly from 0.65 ± 0.13 at baseline to 0.82 ± 0.15 at 30 days. Mean Rutherford category improved from 2.8 ± 0.7 at baseline to 1.0 ± 1.2. In the subgroup with longer follow- up primary patency was 33 % after 12 months and 25 % after 24 months. Secondary patency was 92 % after 12 and 24 months. Conclusions: The use of the Pathway PV™ System during percutaneous peripheral vascular interventions of in-stent restenosis appears to be feasible and safe but does not seem to offer a sustainable solution regarding long term patency. A combination with drug eluting balloon angioplasty could be an interesting option and should be evaluated in further clinical trials.


  • Grading of Carotid Artery Stenosis by Novel Duplex Ultrasound Criteria: Results of the SUPERCAR Study

    by R.R. Macharzina, N. Fan, T. Böhme, C. Claus, A. Rastan, U. Beschorner, F. Neumann, O. Moske-Eick, J. Weber, T. Zeller

  • Evaluation of Color Coded Ultrasound (CCU) for Quantitative Morphometry of Peripheral Arteries as Compared to Angiography: Results of the PeriQuant Registry Study

    by Rr Macharzina, N Fan, W Charlotte, U Schwarzwälder, A Grabs, L Heykendorf, T Böhme, A Rastan, S Sixt, K Bürgelin, et al.

    Problemstellung: Aims: Detection of restenosis by morphologic differentiation of lumen from plaque is an important issue for ultrasonography (US). For evaluation of target lumen reduction (TLR) mostly indirect US-parameters like peak velocity ratios are used. Purpose: To quantitatively assess TLR as a marker of morphometry by intensity-coded power doppler (ICPD) as compared to Color-Doppler (CD), hemodynamic changes in flow velocity and angiography. Patienten und Methode: Patients and Methods: US was performed with a IU 22 (Philips, Germany) using a linear 4–8 Mhz probe. For B-mode imaging XRES and SonoCT was employed. For CD and ICPD dynamic range, persistence, line density and priority were adjusted to maximum sensitivity. Prospective evaluation was off-line by two blinded readers using QLab software (Philips Deutschland, Hamburg). Catheter angiography (Angio) was performed by planes corresponding to longitudinal US-sections (LUSS) with a Siemens HICOR (Siemens, Germany) and evaluated by standard QCA software (Medis, Netherlands). Postinterventional LUSS, cross US-sections (CUSS) and angio were performed in 50 patients with recent stenting of superficial femoral artery (SFA). Ergebnisse: Results: When using ICPD, LUSS and CUSS, axial resolution correlated better with angio than with CD-US. Pearsons Correlations of angiographic diameters with ICPD cross-section views were in stent 0,51 and proximal to stents 0,76 as with longitudinal sections in stent 0,69 and proximal to stents 0,89. ICPD and CD-US underestimated angiographic values predominantly in stent (Bland Altmann, pSchlussfolgerungen: Conclusion: ICPD is suggested to be suitable for analysis of stenosis proximal to stents and morphologic assessment in stent at least in a combined approach with flow measurements.

  • Recanalization of chronic occlusions of the superficial femoral artery using the outback™ re‐entry catheter: A single centre experience

    by Ulrich Beschorner, Sebastian Sixt, Uwe Schwarzwälder, Aljoscha Rastan, Christian Mayer, Elias Noory, Roland Macharzina, Karlheinz Buergelin, Robert Bonvini, Thomas Zeller

    Purpose: To report our experience with a catheter system (The Outback™ catheter) designed to allow fluoroscopically controlled re‐entry after subintimal guide wire passage during recanalization of chronically occluded femoro‐popliteal arteries. Methods: Between March 2007 and August 2008, 65 legs in 61 patients (60% male, mean age 73 (49–98 years) with chronic occlusion of the SFA and proximal popliteal artery were treated. Clinical presentation was severe intermittent claudication (Rutherford category 3, 59%), rest pain (Rutherford category 4, 16%), and minor ulcerations (Rutherford category 5, 25%). In all cases, the true lumen could not be entered by using standard antegrade catheter and guide wire techniques. Results: Median lesion length was 200 ± 102 mm. Recanalization of the arterial occlusion was successful in 57 of 65 treated lesions (88%). One patient died of myocardial infarction after delayed femoral bleeding possibly due to extensive recanalization attempts. There were no further procedure‐related complications. Conclusion: Use of the Outback™ re‐entry catheter system is a valuable option for interventional therapy of chronically occluded femoro‐popliteal arteries following failed standard antegrade recanalization attempt.


  • Percutaneous iliac vein recanalization 17 years after thrombotic occlusion

    by U Beschorner, T Schwarz, A Rastan, S Sixt, E Noory, T Zeller

    Persistent venous outflow obstruction of the iliac veins is one of the mechanisms that seem to portend the greatest risk for late development of severe complications. We report the case of a 42-year-old male with postthrombotic occlusion of the left external iliac vein since the age of 25. We managed to recanalize the obstructed vessel and establish a good flow into the inferior vena cava by venous stenting. After successful intervention the patient reported instant symptom relief and was free from venous claudication and leg heaviness at the 6 month follow-up examination. Even after long history of postthrombotic syndrome, venous stenting can be an option for patients with chronic outflow obstructions of the iliac veins.


  • Quantitative Evaluation and Comparison of In-Stent Target Lumen Reduction by Ultrasound Modalities and Angiography

    by R Macharzina, U Schwarzwälder, Kh Bürgelin, S Sixt, A Rastan, E Noory, U Beschorner, R Brandner, J Neumann, T Zeller

    Background: Detection of restenosis by morphologic differentiation of perfused lumen from plaque is an unresolved issue for ultrasonography (US). Therefore in large trials for evaluation of target lumen reduction (TLR) mostly indirect US-parameters like peak velocity ratios are used in addition to angiographic lumen measurement. Aim: To quantitatively assess TLR as a marker of sonographic morphometry by bidirectional power doppler (BPD) as compared to conventional Color-Doppler (CCD), hemodynamic changes in flow-velocity and angiography. Methods: US was performed with a IU 22 (Philips Germany, Hamburg) using a linear 4–8 Mhz probe. For B-mode imaging XRES and Sono-CT was employed. For CCD and BPD dynamic range, persistence, line density and priority were adjusted to maximum sensitivity and used as a standard setting. Gain control and repetition frequency was individually optimized according to hemodynamics and tissue characteristics. Prospective evaluation was off-line by two blinded readers based on raw-dicom data using QLab software (Philips Deutschland, Hamburg). Angiography was performed by planes corresponding to longitudinal US-sections (LUSS) and evaluated off-line by standard QCA software. Results: postinterventional LUSS, cross US-sections (CUSS) and katheter angiography were performed in 30 patients with stenting of superficial femoral artery (SFA, n=25) and popliteal artery (PA, n=5). When using BPD, LUSS and CUSS axial resolution correlated better with angiographic measurements than with CCD-US. Most adequate In-Stent measurements were achieved with BPD, whereas CCD-US mostly overestimated angiographic values. Interestingly, most stents with postdilatation and angiographically sufficient wall adaptation were found to show narrowing compared to proximal segments mostly within submillimeter range and correspondingly statistically significant flow acceleration (dVm=12cm/s, pDiscussion: BPD showed improved delineation of perfused lumen to plaque structure pre- and in stent as compared to CCD. Reduced blooming and overpainting artifacts by BPD may be the reason for better correlation with angiographic results. CCD favourably detects turbulent flow phenomena after stenosis for exact velocity measurements in sample volumes. Therefore BPD is suggested to be suitable for analysis of in-stent stenosis and morphologic assessment after stent angioplasty at least in a combined approach with CCD. Keywords: Bidirectional Power Doppler Ultrasonography, Color Power Angiography, Quantitative Morphometry, Angiography, Target Lumen Reduction, Stent Angioplasty, Vascular Imaging

  • Histological Diagnosis of Atypical Takayasu Arteritis Using Percutaneous Transluminal Atherectomy

    by Ulrich Beschorner, Heike Goebel, Aljoscha Rastan, Sebastian Sixt, Thomas Zeller

    Purpose: To describe the use of percutaneous directional atherectomy to aid in the diagnosis of atypical Takayasu arteritis in the lower limb vessels. Case Repo...