Matthew B. Weinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Matthew B. Weinger has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alison G. Vredenburgh
Vredenburgh & Associates, Inc. 2588 El Camino Real, F-353 Carlsbad, CA 92008 (760) 434-4741
1 shared publication D C Gonzales
Diego Medical Center
1 shared publicationDavid M. Gaba
1 shared publicationJ Slagle
1 shared publicationJason M. Slagle
1 shared publicationJason Slagle
1 shared publication
Latest Publications
- 1 September 2004
- Published by SAGE Publications in Proceedings of the Human Factors and Ergonomics Society Annual Meeting
- Vol. 48 (16) , 2040-2044
Communication of Drug Hazard Information: A Critical Analysis of the Relationship between the Pharmaceutical Industry, FDA, Clinicians, and Patients and the Impact on Patient Safety
Adverse drug events (ADE) are common, costly, and responsible for significant morbidity and mortality among hospitalized patients. They are a leading cause of death, accounting for up to 106,000 American deaths annually. Our healthcare system relies on accurate reporting of ADE by clinicians to the pharmaceutical companies, and by the companies to the FDA. The system also relies on the pharmaceutical companies providing accurate and complete warnings and contraindications to physicians and patients. Frequently, however, these risks are not effectively communicated to those who prescribe and take the medications. A critical evaluation of the American drug hazard management system reveals several factors that contribute to these shortcomings and therefore impact patient safety. These system components interact to increase the probability of adverse drug events and accordingly, impact consumer safety.
- 1 September 2004
- Published by SAGE Publications in Proceedings of the Human Factors and Ergonomics Society Annual Meeting
- Vol. 48 (16) , 2040-2044
Communication of Drug Hazard Information: A Critical Analysis of the Relationship between the Pharmaceutical Industry, FDA, Clinicians, and Patients and the Impact on Patient Safety
Adverse drug events (ADE) are common, costly, and responsible for significant morbidity and mortality among hospitalized patients. They are a leading cause of death, accounting for up to 106,000 American deaths annually. Our healthcare system relies on accurate reporting of ADE by clinicians to the pharmaceutical companies, and by the companies to the FDA. The system also relies on the pharmaceutical companies providing accurate and complete warnings and contraindications to physicians and patients. Frequently, however, these risks are not effectively communicated to those who prescribe and take the medications. A critical evaluation of the American drug hazard management system reveals several factors that contribute to these shortcomings and therefore impact patient safety. These system components interact to increase the probability of adverse drug events and accordingly, impact consumer safety.
- 1 May 2004
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 98 (5) , 1419-1425
Multiple Measures of Anesthesia Workload During Teaching and Nonteaching Cases
As measured using physiological (provider heart rate), psychological (self-assessment and observer rating), and procedural (response latency to an alarm light and workload density) techniques. Clinicians’ heart rates, observer and self-reported workload scores, and nonteaching workload density were consistently increased during anesthetic induction and emergence compared with maintenance. In nonteaching cases, workload density correlated with heartrate and with psychological workload. Workload density during teaching cases did not decrease during the induction and was significantly greater than during non-teaching cases. Alarm-light response latency (a measure of clinical vigilance) was significantly prolonged during the teaching compared with nonteaching cases. These results suggest that intraoperative teaching increases the workload of the clinician instructor and may reduce vigilance during anesthesia care. Additionally, multiple workload measures may provide a more comprehensive profile of the work demands of clinical cases....
- 1 May 2004
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 98 (5) , 1419-1425
Multiple Measures of Anesthesia Workload During Teaching and Nonteaching Cases
As measured using physiological (provider heart rate), psychological (self-assessment and observer rating), and procedural (response latency to an alarm light and workload density) techniques. Clinicians’ heart rates, observer and self-reported workload scores, and nonteaching workload density were consistently increased during anesthetic induction and emergence compared with maintenance. In nonteaching cases, workload density correlated with heartrate and with psychological workload. Workload density during teaching cases did not decrease during the induction and was significantly greater than during non-teaching cases. Alarm-light response latency (a measure of clinical vigilance) was significantly prolonged during the teaching compared with nonteaching cases. These results suggest that intraoperative teaching increases the workload of the clinician instructor and may reduce vigilance during anesthesia care. Additionally, multiple workload measures may provide a more comprehensive profile of the work demands of clinical cases....
- 1 April 2004
- Published by BMJ in Quality and Safety in Health Care
- Vol. 13 (2) , 136-144
Video capture of clinical care to enhance patient safety
Experience from other domains suggests that videotaping and analyzing actual clinical care can provide valuable insights for enhancing patient safety through improvements in the process of care. Methods are described for the videotaping and analysis of clinical care using a high quality portable multi-angle digital video system that enables simultaneous capture of vital signs and time code synchronization of all data streams. An observer can conduct clinician performance assessment (such as workload measurements or behavioral task analysis) either in real time (during videotaping) or while viewing previously recorded videotapes. Supplemental data are synchronized with the video record and stored electronically in a hierarchical database. The video records are transferred to DVD, resulting in a small, cheap, and accessible archive. A number of technical and logistical issues are discussed, including consent of patients and clinicians, maintaining subject privacy and confidentiality, and data security. Using anesthesiology as a test environment, over 270 clinical cases (872 hours) have been successfully videotaped and processed using the system.
- 1 April 2004
- Published by BMJ in Quality and Safety in Health Care
- Vol. 13 (2) , 136-144
Video capture of clinical care to enhance patient safety
Experience from other domains suggests that videotaping and analyzing actual clinical care can provide valuable insights for enhancing patient safety through improvements in the process of care. Methods are described for the videotaping and analysis of clinical care using a high quality portable multi-angle digital video system that enables simultaneous capture of vital signs and time code synchronization of all data streams. An observer can conduct clinician performance assessment (such as workload measurements or behavioral task analysis) either in real time (during videotaping) or while viewing previously recorded videotapes. Supplemental data are synchronized with the video record and stored electronically in a hierarchical database. The video records are transferred to DVD, resulting in a small, cheap, and accessible archive. A number of technical and logistical issues are discussed, including consent of patients and clinicians, maintaining subject privacy and confidentiality, and data security. Using anesthesiology as a test environment, over 270 clinical cases (872 hours) have been successfully videotaped and processed using the system.
- 1 February 2003
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 36 (1-2) , 106-119
Retrospective data collection and analytical techniques for patient safety studies
- 1 February 2003
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 36 (1-2) , 106-119
Retrospective data collection and analytical techniques for patient safety studies
- 27 February 2002
- Published by American Medical Association (AMA) in JAMA
- Vol. 287 (8) , 955-957
Sleep Deprivation and Clinical Performance
Physicians' ability to provide high-quality care can be adversely affected by many factors, including sleep deprivation. Concerns about the danger of physicia
- 27 February 2002
- Published by American Medical Association (AMA) in JAMA
- Vol. 287 (8) , 955-957
Sleep Deprivation and Clinical Performance
Physicians' ability to provide high-quality care can be adversely affected by many factors, including sleep deprivation. Concerns about the danger of physicia
- 1 November 2001
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 13 (7) , 491-497
Drug wastage contributes significantly to the cost of routine anesthesia care
- 1 November 2001
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 13 (7) , 491-497
Drug wastage contributes significantly to the cost of routine anesthesia care
- 1 December 1999
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 15 (7-8) , 549-552
Vigilance, Boredom, and Sleepiness
- 1 December 1999
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 15 (7-8) , 549-552
Vigilance, Boredom, and Sleepiness
- 1 July 1999
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 15 (5) , 319-323
Anesthesia Equipment and Human Error
- 1 July 1999
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 15 (5) , 319-323
Anesthesia Equipment and Human Error
- 1 July 1997
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 87 (1) , 144-155
The Effect of Electronic Record Keeping and Transesophageal Echocardiography on Task Distribution, Workload, and Vigilance During Cardiac Anesthesia
Background: Electronic anesthesia record keeping (EARK) systems increasingly are used in the operating room, but studies have only recently begun to investigate their effect on anesthesia task performance. Teak analysis, workload assessment, and vigilance assessment techniques were used to study senior residents providing anesthesia for coronary artery bypass graft (CABG) procedures. The impact on anesthesia residents' workload of the routine use of transesophageal echocardiography (TEE) also was examined. Methods: Before each case, the record keeping system was randomly selected as either electronic (Distek ARKIVE; EARK) or traditional manual recording (MAN). Twenty CABG procedures (10 EARK and 10 MAN) were examined, with observation commencing with anesthetic induction and terminating on initiation of cardiopulmonary bypass. The activities of each resident, divided into 32 task categories (e.g., "laryngoscopy," "observe monitors," etc.), were recorded by a trained observer using a computer. The response latency to a randomly activated alarm light was used as a measure of vigilance ("vigilance latency"). Workload was rated by subject and observer at random 10- to 15-min intervals throughout the case. Data analysis included calculation of workload density (number of tasks/min multiplied by task-specific workload values) and task-links (relationship between sequential tasks). Results: The two groups had a similar distribution of tasks before intubation. In only 4 of the 20 cases studied did any manual record keeping occur before intubation. After intubation, the EARK group spent less time record keeping and using the TEE but more time observing the monitors and conversing with the attending physician than the MAN group did. All subjects reported significantly higher workload scores before intubation compared with after intubation. Similarly, vigilance latency was greater before intubation compared with after intubation (57 vs. 31 s; P < 0.001). There were no significant differences between the two record keeping groups in subjective workload scores, workload density, or vigilance latency. During TEE use, vigilance latency was significantly longer, and workload density was greater than during other monitoring or recording tasks. Conclusions: This study provides an objective description of the task distribution and workload during the administration of anesthesia for cardiac surgery. Under the conditions of this study. EARK use modestly decreased the time spent record keeping during the postintubation prebypass period. However, there was no effect of EARK either on vigilance or several measures of workload. TEE use was associated with increased workload and possibly decreased vigilance.
- 1 July 1997
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 87 (1) , 144-155
The Effect of Electronic Record Keeping and Transesophageal Echocardiography on Task Distribution, Workload, and Vigilance During Cardiac Anesthesia
Background: Electronic anesthesia record keeping (EARK) systems increasingly are used in the operating room, but studies have only recently begun to investigate their effect on anesthesia task performance. Teak analysis, workload assessment, and vigilance assessment techniques were used to study senior residents providing anesthesia for coronary artery bypass graft (CABG) procedures. The impact on anesthesia residents' workload of the routine use of transesophageal echocardiography (TEE) also was examined. Methods: Before each case, the record keeping system was randomly selected as either electronic (Distek ARKIVE; EARK) or traditional manual recording (MAN). Twenty CABG procedures (10 EARK and 10 MAN) were examined, with observation commencing with anesthetic induction and terminating on initiation of cardiopulmonary bypass. The activities of each resident, divided into 32 task categories (e.g., "laryngoscopy," "observe monitors," etc.), were recorded by a trained observer using a computer. The response latency to a randomly activated alarm light was used as a measure of vigilance ("vigilance latency"). Workload was rated by subject and observer at random 10- to 15-min intervals throughout the case. Data analysis included calculation of workload density (number of tasks/min multiplied by task-specific workload values) and task-links (relationship between sequential tasks). Results: The two groups had a similar distribution of tasks before intubation. In only 4 of the 20 cases studied did any manual record keeping occur before intubation. After intubation, the EARK group spent less time record keeping and using the TEE but more time observing the monitors and conversing with the attending physician than the MAN group did. All subjects reported significantly higher workload scores before intubation compared with after intubation. Similarly, vigilance latency was greater before intubation compared with after intubation (57 vs. 31 s; P < 0.001). There were no significant differences between the two record keeping groups in subjective workload scores, workload density, or vigilance latency. During TEE use, vigilance latency was significantly longer, and workload density was greater than during other monitoring or recording tasks. Conclusions: This study provides an objective description of the task distribution and workload during the administration of anesthesia for cardiac surgery. Under the conditions of this study. EARK use modestly decreased the time spent record keeping during the postintubation prebypass period. However, there was no effect of EARK either on vigilance or several measures of workload. TEE use was associated with increased workload and possibly decreased vigilance.