Marion Gfrerer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marion Gfrerer has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
E. Lankmayr
Institute for Analytical Chemistry and Radiochemistry, Graz University of Technology, Technikestrasse 4, 8010 Graz, Austria
3 shared publicationsErnst P. Lankmayr
Graz University of Technology, Institute for Analytical Chemistry, Micro- and Radiochemistry, Technikerstr. 4, 8010 Graz, Austria
2 shared publicationsB.M. Gawlik
European Commission DG JRC, Institute for Environment and Sustainability, 21020 Ispra, Italy
1 shared publicationC. Fernandes
Graz University of Technology, Institute of Analytical Chemistry and Radiochemistry
1 shared publicationDonata Bandoniene
Graz University of Technology, Institute for Analytical Chemistry, Micro- and Radiochemistry, Technikerstr. 4, 8010 Graz, Austria
1 shared publication- Ernst Lankmayr
Institute for Analytical Chemistry, University of Technology Graz, A-8010 Graz, Austria
1 shared publication
Latest Publications
- 29 November 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 527 (1) , 53-60
Validation of a fluidized-bed extraction method for solid materials for the determination of PAHs and PCBs using certified reference materials
- 29 November 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 527 (1) , 53-60
Validation of a fluidized-bed extraction method for solid materials for the determination of PAHs and PCBs using certified reference materials
- 4 November 2004
- Published by Springer Nature in Chromatographia
- Vol. 60 (11-12) , 681-686
Optimization of Fluidized-Bed Extraction for Determination of Organochlorine Pesticides in Sediment
- 4 November 2004
- Published by Springer Nature in Chromatographia
- Vol. 60 (11-12) , 681-686
Optimization of Fluidized-Bed Extraction for Determination of Organochlorine Pesticides in Sediment
- 29 October 2004
- Published by Elsevier in Journal of Biochemical and Biophysical Methods
- Vol. 61 (1-2) , 143-153
Comparative study of turbulent solid–liquid extraction methods for the determination of organochlorine pesticides
- 29 October 2004
- Published by Elsevier in Journal of Biochemical and Biophysical Methods
- Vol. 61 (1-2) , 143-153
Comparative study of turbulent solid–liquid extraction methods for the determination of organochlorine pesticides
- 1 April 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (7) , 1861-1867
Comparison of different extraction techniques for the determination of chlorinated pesticides in animal feed
The performances of Soxhlet extraction, dive-in Soxhlet extraction, microwave-assisted extraction (MAE), accelerated solvent extraction (ASE), fluidized-bed extraction (FBE), and ultrasonic extraction (UE) for the analysis of organochlorine pesticides in animal feed have been investigated. ASE and MAE provided significantly better extraction efficiency than Soxhlet extraction. The concentrations were 126.7 and 114.8%, respectively, of the values obtained by classical Soxhlet extraction, whereas the results from FBE and dive-in Soxhlet were comparable with those from the standard Soxhlet procedure. The reproducibility of FBE was the best, with RSDs ranging from 0.3 to 3.9%. Under the investigated operation conditions UE was not efficient, with the recoveries of target compounds being about 50% less than Soxhlet. Additionally, the performances of Soxhlet, dive-in Soxhlet, MAE, ASE and FBE were validated by determination of the certified reference material BCR-115. The results from the extraction techniques were in good agreement with the certified values.
- 1 April 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (7) , 1861-1867
Comparison of different extraction techniques for the determination of chlorinated pesticides in animal feed
The performances of Soxhlet extraction, dive-in Soxhlet extraction, microwave-assisted extraction (MAE), accelerated solvent extraction (ASE), fluidized-bed extraction (FBE), and ultrasonic extraction (UE) for the analysis of organochlorine pesticides in animal feed have been investigated. ASE and MAE provided significantly better extraction efficiency than Soxhlet extraction. The concentrations were 126.7 and 114.8%, respectively, of the values obtained by classical Soxhlet extraction, whereas the results from FBE and dive-in Soxhlet were comparable with those from the standard Soxhlet procedure. The reproducibility of FBE was the best, with RSDs ranging from 0.3 to 3.9%. Under the investigated operation conditions UE was not efficient, with the recoveries of target compounds being about 50% less than Soxhlet. Additionally, the performances of Soxhlet, dive-in Soxhlet, MAE, ASE and FBE were validated by determination of the certified reference material BCR-115. The results from the extraction techniques were in good agreement with the certified values.
- 1 November 2003
- Published by Springer Fachmedien Wiesbaden GmbH in Chromatographia
- Vol. 58 (9-10) , 631-636
Optimization of Accelerated Solvent Extraction for the Determination of Chlorinated Pesticides from Animal Feed
In the present study accelerated solvent extraction (ASE) was investigated for the extraction of organochlorine pesticides from animal feed. The factors in
- 1 November 2003
- Published by Springer Fachmedien Wiesbaden GmbH in Chromatographia
- Vol. 58 (9-10) , 631-636
Optimization of Accelerated Solvent Extraction for the Determination of Chlorinated Pesticides from Animal Feed
In the present study accelerated solvent extraction (ASE) was investigated for the extraction of organochlorine pesticides from animal feed. The factors in
- 1 February 2003
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 83 (2) , 111-125
Multi-residue Analysis of 66 Biocides in River Water, River Sediment and Suspended Solids Samples by Gas Chromatography-Mass Spectrometry
A multi-residue method for the screening and analysis of 66 common pesticides from hydrological samples, including sediment, suspended solids and water is presented. The investigated pesticides belong to the following chemical classes: polychlorinated organic compounds, triazine- and chloroacetanilide herbicides, organophosphorous insecticides and miscellaneous. The method includes fluidized-bed and microwave-assisted extraction for solid samples and solid-phase extraction on C 18 -cartridges for water samples, followed by a combined purification-separation step on adsorption chromatography using open silica gel columns. Two fractions were eluted separating the 66 analytes into the non-polar and the more polar compounds. All analytes were identified and quantified by gas chromatography coupled with mass spectrometry in selected ion monitoring mode. The method was characterized by recovery experiments and statistical methods and finally applied to environmental river samples during a one-year monitoring program. This method allowed the screening and measurement of the contaminants in all parts of Liao-He and Yangtse rivers (Eastern China) at levels as low as 0.07 ng/L resp. 0.7 ng/L for hexachlorobenzene, with a precision better than 20%.
- 1 February 2003
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 83 (2) , 111-125
Multi-residue Analysis of 66 Biocides in River Water, River Sediment and Suspended Solids Samples by Gas Chromatography-Mass Spectrometry
A multi-residue method for the screening and analysis of 66 common pesticides from hydrological samples, including sediment, suspended solids and water is presented. The investigated pesticides belong to the following chemical classes: polychlorinated organic compounds, triazine- and chloroacetanilide herbicides, organophosphorous insecticides and miscellaneous. The method includes fluidized-bed and microwave-assisted extraction for solid samples and solid-phase extraction on C 18 -cartridges for water samples, followed by a combined purification-separation step on adsorption chromatography using open silica gel columns. Two fractions were eluted separating the 66 analytes into the non-polar and the more polar compounds. All analytes were identified and quantified by gas chromatography coupled with mass spectrometry in selected ion monitoring mode. The method was characterized by recovery experiments and statistical methods and finally applied to environmental river samples during a one-year monitoring program. This method allowed the screening and measurement of the contaminants in all parts of Liao-He and Yangtse rivers (Eastern China) at levels as low as 0.07 ng/L resp. 0.7 ng/L for hexachlorobenzene, with a precision better than 20%.