Xin-Sheng Chai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xin-Sheng Chai has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
F. J. Schork
School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, 311 Ferst Drive, Atlanta, Georgia 30332
2 shared publicationsHuai-Yu Zhan
2 shared publicationsQ. X. Hou
Institute of Paper Science and Technology, Georgia Institute of Technology, 500 10th Street Northwest, Atlanta, Georgia 30332
2 shared publicationsShi-Yu Fu
2 shared publicationsChunxu Dong
Institute of Paper Science and Technology and School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Alanta, Georgia 30332, and State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian, China 116012
1 shared publication- Cui Zhang
State Key Laboratory of Pulp and Paper Engineering, South China University of Technology, Guangzhou 510640, China
1 shared publication
Latest Publications
- 1 June 2012
- Vol. 32 (6) , 1681-4
[Rapid determination of silicon content in black liquor of straw fibrous material].
The present paper reports a novel method for the determination of silicon content in straw fibrous material black liquor based on alpha-Si--Mo heteropoly acid spectrophotometry. The selected conditions were as follows: detection wavelength 360 nm, pH 4.0, and reaction time 10 min. It was found that the acidic soluble lignin in the sample liquor was the major interference species in the silicon content determination. The interference of acidic soluble lignin can be eliminated by hydrogen peroxide-nitric acid digestion method. The present method is not only simple, rapid, stable and less interferential, but also of good measurement precision and accuracy, with the relative standard deviations of 0.9%, and recoveries of 99.0%-102%. It is suitable for use in high silicon content of black liquor routine rapid analyses.
- 1 June 2012
- Vol. 32 (6) , 1681-4
[Rapid determination of silicon content in black liquor of straw fibrous material].
The present paper reports a novel method for the determination of silicon content in straw fibrous material black liquor based on alpha-Si--Mo heteropoly acid spectrophotometry. The selected conditions were as follows: detection wavelength 360 nm, pH 4.0, and reaction time 10 min. It was found that the acidic soluble lignin in the sample liquor was the major interference species in the silicon content determination. The interference of acidic soluble lignin can be eliminated by hydrogen peroxide-nitric acid digestion method. The present method is not only simple, rapid, stable and less interferential, but also of good measurement precision and accuracy, with the relative standard deviations of 0.9%, and recoveries of 99.0%-102%. It is suitable for use in high silicon content of black liquor routine rapid analyses.
- 3 April 2012
- Published by Taylor & Francis in Journal of Wood Chemistry and Technology
- Vol. 32 (3) , 187-197
Oxalate Release and Formation during Alkaline Pulping
In this work, we investigated the release and formation of oxalate during alkaline pulping of southern pine and acacia. The results showed that a significant amount of oxalate is formed during alkaline pulping in addition to the oxalate released from the wood. Acacia was found to have more oxalate in the wood and it also resulted in more oxalate formation than southern pine. A higher hydroxide concentration leads to higher oxalate content in the black liquor during the early stages of the cook. Oxalate formation can be described as a function of pulping time and temperature (H-factor), and the initial hydroxide concentration of the cooking liquor. More work is needed to understand the fundamental mechanism to produce a more fundamental predictive model for other wood species.
- 3 April 2012
- Published by Taylor & Francis in Journal of Wood Chemistry and Technology
- Vol. 32 (3) , 187-197
Oxalate Release and Formation during Alkaline Pulping
In this work, we investigated the release and formation of oxalate during alkaline pulping of southern pine and acacia. The results showed that a significant amount of oxalate is formed during alkaline pulping in addition to the oxalate released from the wood. Acacia was found to have more oxalate in the wood and it also resulted in more oxalate formation than southern pine. A higher hydroxide concentration leads to higher oxalate content in the black liquor during the early stages of the cook. Oxalate formation can be described as a function of pulping time and temperature (H-factor), and the initial hydroxide concentration of the cooking liquor. More work is needed to understand the fundamental mechanism to produce a more fundamental predictive model for other wood species.
- 1 January 2010
- Vol. 30 (1) , 247-50
[Rapid method for determination of furfural and 5-hydroxymethyl furfural in pre-extraction stream of biomass using UV spectroscopy].
The present paper reports a rapid method for the determination of furfural (F) and 5-hydroxymethyl furfural (HMF) in pre-extraction liquors of lignocellulosic biomass based on UV spectroscopy. In a concentrated acetic acid medium, F and HMF have an isosbestic point at 276 nm. It was found that the acidic soluble lignin in the pre-extraction sample is the major interference species in the F and HMF spectroscopic quantification However, only acidic soluble lignins have the absorption at the wavelengths above 325 nm. Based on the absorption of the acidic soluble lignins at 325 nm, their absorptions at either F or HMF absorbed wavelengths can be determined. Thus, with a simple triple-wavelength technique, both F and HMF in the pre-extraction liquors of lignocellulosic biomass can be quantified based on the spectroscopic measurement at the isosbestic point wavelength (276 nm), maximum absorption wavelength of F (272 nm) and the acid soluble lignin absorbed wavelength (325 nm). The present method does not require the hazardous organic compounds (such as phenolic compounds etc.) acting as a color reagent in the experiment. It is not only simple and rapid, but also has a good measurement precision and accuracy, with the relative standard deviations of 3.02% and 2.72%, and recoveries of 95%-107% and 96%-101%, respectively, in the F and HMF quantification. The present method is suitable for use in the research on pre-extraction hemicellulose of the lignocellulosic biomass in bio-refinery area in order to achieve a high selective sugar conversion.
- 1 January 2010
- Vol. 30 (1) , 247-50
[Rapid method for determination of furfural and 5-hydroxymethyl furfural in pre-extraction stream of biomass using UV spectroscopy].
The present paper reports a rapid method for the determination of furfural (F) and 5-hydroxymethyl furfural (HMF) in pre-extraction liquors of lignocellulosic biomass based on UV spectroscopy. In a concentrated acetic acid medium, F and HMF have an isosbestic point at 276 nm. It was found that the acidic soluble lignin in the pre-extraction sample is the major interference species in the F and HMF spectroscopic quantification However, only acidic soluble lignins have the absorption at the wavelengths above 325 nm. Based on the absorption of the acidic soluble lignins at 325 nm, their absorptions at either F or HMF absorbed wavelengths can be determined. Thus, with a simple triple-wavelength technique, both F and HMF in the pre-extraction liquors of lignocellulosic biomass can be quantified based on the spectroscopic measurement at the isosbestic point wavelength (276 nm), maximum absorption wavelength of F (272 nm) and the acid soluble lignin absorbed wavelength (325 nm). The present method does not require the hazardous organic compounds (such as phenolic compounds etc.) acting as a color reagent in the experiment. It is not only simple and rapid, but also has a good measurement precision and accuracy, with the relative standard deviations of 3.02% and 2.72%, and recoveries of 95%-107% and 96%-101%, respectively, in the F and HMF quantification. The present method is suitable for use in the research on pre-extraction hemicellulose of the lignocellulosic biomass in bio-refinery area in order to achieve a high selective sugar conversion.
- 25 September 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (20) , 7820-7825
In Situ Determination of Bacterial Growth by Multiple Headspace Extraction Gas Chromatography
This paper demonstrated an in situ headspace gas chromatography (GC) technique for monitoring bacterial growth using a commercial GC system with a multiple headspace extraction (sampling) mode. The technique was based on measuring the carbon dioxide mass in the headspace of a closed sample vial during the bacteria growth. A mathematic equation was derived in order to calculate the integrated amount of carbon dioxide produced by bacterial growth during the incubation. The method can be used to monitor the bacterial growth rate in a given cultural medium. The present method is very simple, sensitive, and safe.
- 25 September 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (20) , 7820-7825
In Situ Determination of Bacterial Growth by Multiple Headspace Extraction Gas Chromatography
This paper demonstrated an in situ headspace gas chromatography (GC) technique for monitoring bacterial growth using a commercial GC system with a multiple headspace extraction (sampling) mode. The technique was based on measuring the carbon dioxide mass in the headspace of a closed sample vial during the bacteria growth. A mathematic equation was derived in order to calculate the integrated amount of carbon dioxide produced by bacterial growth during the incubation. The method can be used to monitor the bacterial growth rate in a given cultural medium. The present method is very simple, sensitive, and safe.
- 29 April 2008
- Published by Springer Nature in Science in China Series B: Chemistry
- Vol. 51 (5) , 473-478
Study of adsorption kinetics for fluorescent whitening agent on fiber surfaces
- 29 April 2008
- Published by Springer Nature in Science in China Series B: Chemistry
- Vol. 51 (5) , 473-478
Study of adsorption kinetics for fluorescent whitening agent on fiber surfaces
- 1 March 2006
- Published by Elsevier in Journal of Chromatography A
- Vol. 1108 (1) , 14-19
Determination of microstickies in recycled whitewater by headspace gas chromatography
- 1 March 2006
- Published by Elsevier in Journal of Chromatography A
- Vol. 1108 (1) , 14-19
Determination of microstickies in recycled whitewater by headspace gas chromatography
- 1 March 2006
- Published by Elsevier in Journal of Membrane Science
- Vol. 271 (1-2) , 215-220
Novel mechanism for the Nafion membrane transfer of anthraquinones
- 1 March 2006
- Published by Elsevier in Journal of Membrane Science
- Vol. 271 (1-2) , 215-220
Novel mechanism for the Nafion membrane transfer of anthraquinones
- 18 November 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 99 (3) , 1296-1301
Determination of the solubility of a monomer in water by multiple headspace extraction gas chromatography
In water‐based polymerization (suspension, microsuspension, emulsion, miniemulsion, and microemulsion polymerization), the solubility of the monomer in the aqueous phase can have profound effects on the final polymer product. This article demonstrates a novel method for the determination of monomer solubility in water with headspace gas chromatography (GC). In this method, an excess amount of an organic solute of interest was added into a closed headspace vial containing a given volume of water. The organic solute and water in the vial was well mixed by strong hand shaking; then, the equilibrated vapor solute in the vial at a desired temperature was measured by headspace GC with a multiple headspace extraction mode. In each headspace extraction, a part of the vapor phase in the vial was vented for GC analysis and replaced with an inert gas. The excess amount of solute in aqueous solution was eventually removed from the vial after multiple headspace extractions, and the solute concentration in water reached its saturation point. After that point, the concentration of the solute in the vapor dramatically decreased in each subsequent headspace extraction. By plotting vapor concentration versus headspace extraction number, we determined the transition point. The vapor concentration at this point corresponded to the solute solubility, which was calculated through a calibration. This method was very simple and automated; it could easily be used for organic solute solubility measurement at an elevated temperature. © 2005 Wiley Periodicals, Inc. J Appl Polym Sci 99: 1296–1301, 2006
- 18 November 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 99 (3) , 1296-1301
Determination of the solubility of a monomer in water by multiple headspace extraction gas chromatography
In water‐based polymerization (suspension, microsuspension, emulsion, miniemulsion, and microemulsion polymerization), the solubility of the monomer in the aqueous phase can have profound effects on the final polymer product. This article demonstrates a novel method for the determination of monomer solubility in water with headspace gas chromatography (GC). In this method, an excess amount of an organic solute of interest was added into a closed headspace vial containing a given volume of water. The organic solute and water in the vial was well mixed by strong hand shaking; then, the equilibrated vapor solute in the vial at a desired temperature was measured by headspace GC with a multiple headspace extraction mode. In each headspace extraction, a part of the vapor phase in the vial was vented for GC analysis and replaced with an inert gas. The excess amount of solute in aqueous solution was eventually removed from the vial after multiple headspace extractions, and the solute concentration in water reached its saturation point. After that point, the concentration of the solute in the vapor dramatically decreased in each subsequent headspace extraction. By plotting vapor concentration versus headspace extraction number, we determined the transition point. The vapor concentration at this point corresponded to the solute solubility, which was calculated through a calibration. This method was very simple and automated; it could easily be used for organic solute solubility measurement at an elevated temperature. © 2005 Wiley Periodicals, Inc. J Appl Polym Sci 99: 1296–1301, 2006
- 1 November 2005
- Published by Elsevier in Journal of Chromatography A
- Vol. 1093 (1-2) , 212-216
Determination of acidic and basic species by headspace gas chromatography
- 1 November 2005
- Published by Elsevier in Journal of Chromatography A
- Vol. 1093 (1-2) , 212-216
Determination of acidic and basic species by headspace gas chromatography
- 18 October 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 99 (1) , 392-397
Determination of the methyl methacrylate monomer in its polymer latex by headspace gas chromatography
This article reports a headspace gas chromatography (GC) method for the determination of the residual monomer in a methyl methacrylate polymer latex or emulsion. Because of the multiphase nature of a polymer latex, the level of the residual monomer cannot be quantified by headspace GC on the basis of its vapor–liquid equilibrium (VLE) without significant thermodynamic assumptions. With a significant dilution of a polymer latex sample followed by vapor–liquid equilibration at an elevated temperature, the monomer droplets are completely dissolved in the aqueous phase, and monomer absorption in the polymer particles can be minimized. Thus, VLE is established in the diluted latex, and a linear relationship between the monomer concentration in the vapor and aqueous phases can be obtained. This technique eliminates sample pretreatment procedures such as solvent extraction in the conventional GC method, and it avoids the risk of polymer deposition on the GC column caused by a direct injection of a monomer‐containing solvent. It also eliminates the possibility of solvent interference in the conventional GC monomer analysis. This method is simple, accurate, and automated. © 2005 Wiley Periodicals, Inc. J Appl Polym Sci 99: 392–397, 2006
- 18 October 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 99 (1) , 392-397
Determination of the methyl methacrylate monomer in its polymer latex by headspace gas chromatography
This article reports a headspace gas chromatography (GC) method for the determination of the residual monomer in a methyl methacrylate polymer latex or emulsion. Because of the multiphase nature of a polymer latex, the level of the residual monomer cannot be quantified by headspace GC on the basis of its vapor–liquid equilibrium (VLE) without significant thermodynamic assumptions. With a significant dilution of a polymer latex sample followed by vapor–liquid equilibration at an elevated temperature, the monomer droplets are completely dissolved in the aqueous phase, and monomer absorption in the polymer particles can be minimized. Thus, VLE is established in the diluted latex, and a linear relationship between the monomer concentration in the vapor and aqueous phases can be obtained. This technique eliminates sample pretreatment procedures such as solvent extraction in the conventional GC method, and it avoids the risk of polymer deposition on the GC column caused by a direct injection of a monomer‐containing solvent. It also eliminates the possibility of solvent interference in the conventional GC monomer analysis. This method is simple, accurate, and automated. © 2005 Wiley Periodicals, Inc. J Appl Polym Sci 99: 392–397, 2006