Philippe P. R. Rosias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Philippe P. R. Rosias has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
Edward Dompeling
Department of Paediatric Pulmonology, Care and Public Health Research Institute, University Hospital Maastricht, Maastricht
4 shared publicationsQuirijn Jöbsis
Department of Paediatric Pulmonology, Care and Public Health Research Institute, University Hospital Maastricht, Maastricht
4 shared publicationsC. M. Robroeks
2 shared publicationsE. Dompeling
2 shared publicationsQ. Jöbsis
2 shared publicationsA. D. Kester
1 shared publication
Latest Publications
- Open Access
- 23 February 2016
- Published by Sciedu Press in Case Reports in Internal Medicine
- Vol. 3 (2) , p15
Iron-deficiency anemia due to massive trichobezoar
This case-report describes a 15-year-old girl who presented at the outpatient department with iron-defiency anemia. Physical examination showed a mass in the left upper quadrant. Additional ultrasound, MRI and gastroscopy revealed a large trichobezoar and extensive bleeding ulcera in the stomach. The trichobezoar was successfully removed during surgery. Patient recovery was complete, and psychiatric treatment was initiated to prevent relapse of trichotillomania and trichophagia.
- 23 February 2016
- Published by Sciedu Press in Case Reports in Internal Medicine
- Vol. 3 (2) , p15
Open AccessIron-deficiency anemia due to massive trichobezoar
This case-report describes a 15-year-old girl who presented at the outpatient department with iron-defiency anemia. Physical examination showed a mass in the left upper quadrant. Additional ultrasound, MRI and gastroscopy revealed a large trichobezoar and extensive bleeding ulcera in the stomach. The trichobezoar was successfully removed during surgery. Patient recovery was complete, and psychiatric treatment was initiated to prevent relapse of trichotillomania and trichophagia.
- Open Access
- 7 November 2012
- Published by Elsevier in Respiratory Medicine Case Reports
- Vol. 7, 4-7
Clinical presentation of Churg–Strauss syndrome in children
- 7 November 2012
- Published by Elsevier in Respiratory Medicine Case Reports
- Vol. 7, 4-7
Open AccessClinical presentation of Churg–Strauss syndrome in children
- 20 April 2012
- Published by IOP Publishing in Journal of Breath Research
- Vol. 6 (2) , 027102
Methodological aspects of exhaled breath condensate collection and analysis
The collection and analysis of exhaled breath condensate (EBC) may be useful for the management of patients with chronic respiratory disease at all ages. It is a promising technique due to its apparent simplicity and non-invasiveness. EBC does not disturb an ongoing respiratory inflammation. However, the methodology remains controversial, as it is not yet standardized. The current diversity of the methods used to collect and preserve EBC, the analytical pitfalls and the high degree of within-subject variability are the main issues that hamper further development into a clinical useful technique. In order to facilitate the process of standardization, a simplified schematic approach is proposed. An update of available data identified open issues on EBC methodology. These issues were then classified into three separate conditions related to their influence before, during or after the condensation process: (1) pre-condenser conditions related to subject and/or environment; (2) condenser conditions related to condenser equipment; and (3) post-condenser conditions related to preservation and/or analysis. This simplified methodological approach highlights the potential influence of the many techniques used before, during and after condensation of exhaled breath. It may also serve as a methodological checklist for a more systematical approach of EBC research and development.
- 20 April 2012
- Published by IOP Publishing in Journal of Breath Research
- Vol. 6 (2) , 027102
Methodological aspects of exhaled breath condensate collection and analysis
The collection and analysis of exhaled breath condensate (EBC) may be useful for the management of patients with chronic respiratory disease at all ages. It is a promising technique due to its apparent simplicity and non-invasiveness. EBC does not disturb an ongoing respiratory inflammation. However, the methodology remains controversial, as it is not yet standardized. The current diversity of the methods used to collect and preserve EBC, the analytical pitfalls and the high degree of within-subject variability are the main issues that hamper further development into a clinical useful technique. In order to facilitate the process of standardization, a simplified schematic approach is proposed. An update of available data identified open issues on EBC methodology. These issues were then classified into three separate conditions related to their influence before, during or after the condensation process: (1) pre-condenser conditions related to subject and/or environment; (2) condenser conditions related to condenser equipment; and (3) post-condenser conditions related to preservation and/or analysis. This simplified methodological approach highlights the potential influence of the many techniques used before, during and after condensation of exhaled breath. It may also serve as a methodological checklist for a more systematical approach of EBC research and development.
- 18 February 2010
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 21 (1-Part-II) , e235-e244
Feasibility of a new method to collect exhaled breath condensate in pre‐school children
Rosias PPR, Robroeks CM, van de Kant KD, Rijkers GT, Zimmermann LJ, van Schayck CP, Heynens JW, Jöbsis Q, Dompeling E. Feasibility of a new method to collect exhaled breath condensate in pre‐school children. Pediatr Allergy Immunol 2010: 21: e235–e244. © 2009 John Wiley & Sons A/SExhaled breath condensate (EBC) is a promising non‐invasive method to assess respiratory inflammation in adults and children with lung disease. Especially in pre‐school children, condensate collection is hampered by long sampling times because of open‐ended collection systems. We aimed to assess the feasibility of condensate collection in pre‐school children using a closed glass condenser with breath recirculation system, which also collects the residual non‐condensed exhaled breath, and subsequently recirculates it back into the condenser. Condensate was collected before and after breath recirculation in 70 non‐sedated pre‐school children with and without recurrent wheeze. Cytokines (IL‐4, IL‐5, IL‐6, IL‐8, IL‐10, IL‐12p70, IL‐13, TNF‐α) were measured in 50 μl samples using ultrasensitive multiplexed liquid bead array. The success rate of condensate collection increased from 64% (without recirculation) to 83% (after breath recirculation), and mean condensate volume from 214 to 465 μl respectively. Detection of cytokines was successful in 95–100% of samples. Cytokine concentrations before and after breath recirculation were not different (p > 0.232). In asthmatic children, only TNF‐α concentrations were significantly decreased, compared to non‐asthmatics. In pre‐school children, the collection of EBC is feasible using a new closed glass condenser with breath recirculation system. This new method may help to assess – non‐invasively – cytokine profiles in asthmatic and non‐asthmatic pre‐school children.
- 18 February 2010
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 21 (1-Part-II) , e235-e244
Feasibility of a new method to collect exhaled breath condensate in pre‐school children
Rosias PPR, Robroeks CM, van de Kant KD, Rijkers GT, Zimmermann LJ, van Schayck CP, Heynens JW, Jöbsis Q, Dompeling E. Feasibility of a new method to collect exhaled breath condensate in pre‐school children. Pediatr Allergy Immunol 2010: 21: e235–e244. © 2009 John Wiley & Sons A/SExhaled breath condensate (EBC) is a promising non‐invasive method to assess respiratory inflammation in adults and children with lung disease. Especially in pre‐school children, condensate collection is hampered by long sampling times because of open‐ended collection systems. We aimed to assess the feasibility of condensate collection in pre‐school children using a closed glass condenser with breath recirculation system, which also collects the residual non‐condensed exhaled breath, and subsequently recirculates it back into the condenser. Condensate was collected before and after breath recirculation in 70 non‐sedated pre‐school children with and without recurrent wheeze. Cytokines (IL‐4, IL‐5, IL‐6, IL‐8, IL‐10, IL‐12p70, IL‐13, TNF‐α) were measured in 50 μl samples using ultrasensitive multiplexed liquid bead array. The success rate of condensate collection increased from 64% (without recirculation) to 83% (after breath recirculation), and mean condensate volume from 214 to 465 μl respectively. Detection of cytokines was successful in 95–100% of samples. Cytokine concentrations before and after breath recirculation were not different (p > 0.232). In asthmatic children, only TNF‐α concentrations were significantly decreased, compared to non‐asthmatics. In pre‐school children, the collection of EBC is feasible using a new closed glass condenser with breath recirculation system. This new method may help to assess – non‐invasively – cytokine profiles in asthmatic and non‐asthmatic pre‐school children.
- 9 January 2008
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 31 (5) , 934-942
Biomarker reproducibility in exhaled breath condensate collected with different condensers
Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H2O2), 8-isoprostane and cytokine measurements using different condensers, including a newly developed glass condenser.At four points in time, 30 healthy subjects performed sequential EBC collections randomly using the following four condensers: glass, silicone, EcoScreen® (Erich Jaeger GmbH, Hoechberg, Germany) and an optimised glass condenser. In small EBC samples, H2O2was measured by spectrophotometer, 8-isoprostane by enzyme immunoassay, and cytokines by multiplexed xMAP® technology (Luminex Corporation, Austin, TX, USA).The optimised glass condenser yielded significantly more EBC volume (median 2,025 µL, interquartile range 1,600–2,525). The reproducibility of EBC volume, yielded by the new glass condenser, was comparable with EcoScreen® (19–20 coefficients of variation (CV)%), but was significantly better compared with silicone and glass (29–37 CV%). The new condenser was associated with significantly more detections of H2O2, 8-isoprostane, interleukin-2, -4, -5 and -13, and tumour necrosis factor-α. Isoprostane concentrations were significantly higher using the new condenser, whereas H2O2and cytokine concentrations were not. Reproducibility of biomarkers was equally variable for all condenser types.In conclusion, significantly more exhaled breath condensate volume and biomarker detections were found using the optimised glass condenser, including higher 8-isoprostane levels. However, biomarker reproducibility in exhaled breath condensate in healthy adults was not influenced by the type of condenser.
- 9 January 2008
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 31 (5) , 934-942
Biomarker reproducibility in exhaled breath condensate collected with different condensers
Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H2O2), 8-isoprostane and cytokine measurements using different condensers, including a newly developed glass condenser.At four points in time, 30 healthy subjects performed sequential EBC collections randomly using the following four condensers: glass, silicone, EcoScreen® (Erich Jaeger GmbH, Hoechberg, Germany) and an optimised glass condenser. In small EBC samples, H2O2was measured by spectrophotometer, 8-isoprostane by enzyme immunoassay, and cytokines by multiplexed xMAP® technology (Luminex Corporation, Austin, TX, USA).The optimised glass condenser yielded significantly more EBC volume (median 2,025 µL, interquartile range 1,600–2,525). The reproducibility of EBC volume, yielded by the new glass condenser, was comparable with EcoScreen® (19–20 coefficients of variation (CV)%), but was significantly better compared with silicone and glass (29–37 CV%). The new condenser was associated with significantly more detections of H2O2, 8-isoprostane, interleukin-2, -4, -5 and -13, and tumour necrosis factor-α. Isoprostane concentrations were significantly higher using the new condenser, whereas H2O2and cytokine concentrations were not. Reproducibility of biomarkers was equally variable for all condenser types.In conclusion, significantly more exhaled breath condensate volume and biomarker detections were found using the optimised glass condenser, including higher 8-isoprostane levels. However, biomarker reproducibility in exhaled breath condensate in healthy adults was not influenced by the type of condenser.
- 26 July 2006
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 28 (5) , 1036-1041
Breath condenser coatings affect measurement of biomarkers in exhaled breath condensate
Exhaled breath condensate collection is not yet standardised and biomarker measurements are often close to lower detection limits. In the current study, it was hypothesised that adhesive properties of different condenser coatings interfere with measurements of eicosanoids and proteins in breath condensate.In vitro,condensate was derived from a collection model using two test solutions (8-isoprostane and albumin) and five condenser coatings (silicone, glass, aluminium, polypropylene and Teflon).In vivo, condensate was collected using these five coatings and the EcoScreen® condenser to measure 8-isoprostane, and three coatings (silicone, glass, EcoScreen®) to measure albumin.In vitro, silicone and glass coatings had significantly higher albumin recovery compared with the other coatings. A similar trend was observed for 8-isoprostane recovery.In vivo,median (interquartile range) 8-isoprostane concentrations were significantly higher using silicone (9.2 (18.8) pg·mL-1) or glass (3.0 (4.5) pg·mL-1) coating, compared with aluminium (0.5 (2.4) pg·mL-1), polypropylene (0.5 (0.5) pg·mL-1), Teflon (0.5 (0.0) pg·mL-1), and EcoScreen® (0.5 (2.0) pg·mL-1). Albuminin vivowas mainly detectable using glass coating.In conclusion, a condenser with silicone or glass coating is more efficient for measurement of 8-isoprostane or albumin in exhaled breath condensate, than EcoScreen®, aluminium, polypropylene or Teflon. Guidelines for exhaled breath condensate standardisation should include the most valid condenser coating to measure a specific biomarker.
- 26 July 2006
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 28 (5) , 1036-1041
Breath condenser coatings affect measurement of biomarkers in exhaled breath condensate
Exhaled breath condensate collection is not yet standardised and biomarker measurements are often close to lower detection limits. In the current study, it was hypothesised that adhesive properties of different condenser coatings interfere with measurements of eicosanoids and proteins in breath condensate.In vitro,condensate was derived from a collection model using two test solutions (8-isoprostane and albumin) and five condenser coatings (silicone, glass, aluminium, polypropylene and Teflon).In vivo, condensate was collected using these five coatings and the EcoScreen® condenser to measure 8-isoprostane, and three coatings (silicone, glass, EcoScreen®) to measure albumin.In vitro, silicone and glass coatings had significantly higher albumin recovery compared with the other coatings. A similar trend was observed for 8-isoprostane recovery.In vivo,median (interquartile range) 8-isoprostane concentrations were significantly higher using silicone (9.2 (18.8) pg·mL-1) or glass (3.0 (4.5) pg·mL-1) coating, compared with aluminium (0.5 (2.4) pg·mL-1), polypropylene (0.5 (0.5) pg·mL-1), Teflon (0.5 (0.0) pg·mL-1), and EcoScreen® (0.5 (2.0) pg·mL-1). Albuminin vivowas mainly detectable using glass coating.In conclusion, a condenser with silicone or glass coating is more efficient for measurement of 8-isoprostane or albumin in exhaled breath condensate, than EcoScreen®, aluminium, polypropylene or Teflon. Guidelines for exhaled breath condensate standardisation should include the most valid condenser coating to measure a specific biomarker.
- 1 January 2006
- Published by Taylor & Francis in Free Radical Research
- Vol. 40 (9) , 901-909
Free radicals in exhaled breath condensate in cystic fibrosis and healthy subjects
Many markers of airway inflammation and oxidative stress can be measured non-invasively in exhaled breath condensate (EBC). However, no attempt has been made to directly detect free radicals using electron paramagnetic resonance (EPR) spectroscopy. Condensate was collected in 14 children with cystic fibrosis (CF) and seven healthy subjects. Free radicals were trapped by 5,5-dimethyl-1-pyrroline-N-oxide. EPR spectra were recorded using a Bruker EMX® spectrometer. Secondly, to study the source of oxygen centered radical formation, catalase or hydrogen peroxide was added to the condensate. Radicals were detected in 18 out of 21 condensate samples. Analysis of spectra indicated that both oxygen and carbon centered radicals were trapped. Within-subject reproducibility was good in all but one subject. Quantitatively, there was a trend towards higher maximal peak heights of both oxygen and carbon centered radicals in the children with CF. Catalase completely suppressed the signals in condensate. Addition of hydrogen peroxide resulted in increased radical signal intensity. Detection of free radicals in EBC of children with CF and healthy subjects is feasible using EPR spectroscopy.
- 1 January 2006
- Published by Taylor & Francis in Free Radical Research
- Vol. 40 (9) , 901-909
Free radicals in exhaled breath condensate in cystic fibrosis and healthy subjects
Many markers of airway inflammation and oxidative stress can be measured non-invasively in exhaled breath condensate (EBC). However, no attempt has been made to directly detect free radicals using electron paramagnetic resonance (EPR) spectroscopy. Condensate was collected in 14 children with cystic fibrosis (CF) and seven healthy subjects. Free radicals were trapped by 5,5-dimethyl-1-pyrroline-N-oxide. EPR spectra were recorded using a Bruker EMX® spectrometer. Secondly, to study the source of oxygen centered radical formation, catalase or hydrogen peroxide was added to the condensate. Radicals were detected in 18 out of 21 condensate samples. Analysis of spectra indicated that both oxygen and carbon centered radicals were trapped. Within-subject reproducibility was good in all but one subject. Quantitatively, there was a trend towards higher maximal peak heights of both oxygen and carbon centered radicals in the children with CF. Catalase completely suppressed the signals in condensate. Addition of hydrogen peroxide resulted in increased radical signal intensity. Detection of free radicals in EBC of children with CF and healthy subjects is feasible using EPR spectroscopy.
- 16 June 2004
- Published by Wiley in Pediatric Pulmonology
- Vol. 38 (2) , 107-114
Childhood asthma: Exhaled markers of airway inflammation, asthma control score, and lung function tests
Exhaled markers of airway inflammation become increasingly important in the management of childhood asthma. The aims of the present study are: 1) to compare exhaled markers of inflammation (nitric oxide, carbon monoxide, and acidity of breath condensate) with conventional asthma measures (lung function tests and asthma control score) in childhood asthma; and 2) to investigate the detectability of albumin, CRP, IL‐6, IL‐8, TNF‐alpha, sICAM‐1, and sTNF‐R75 in the exhaled breath condensate (EBC) of asthmatic children. Thirty‐two children with mild to moderate persistent asthma and healthy controls aged 6–12 years were studied. We measured exhaled NO and CO, and subsequently EBC was collected. Inflammatory mediators in EBC were measured using an enzyme‐linked immunosorbent assay. Respiratory symptoms and asthma control were assessed using the asthma control questionnaire (ACQ) of Juniper et al. (Eur Respir J 1999;14:902–907). Exhaled NO showed a significant correlation with exhaled CO (r = 0.59,P < 0.05) and FEV1(r = −0.59,P < 0.05), but not with ACQ score (r = 0.48,P = 0.06). Exhaled CO was correlated with prebronchodilator FEV1(r = −0.45,P < 0.05), but not with asthma control (r = 0.18,P = 0.35). Acidity of EBC was significantly lower in asthmatic children than in healthy controls (P < 0.05), but did not correlate with any of the conventional asthma measures. We were not able to demonstrate the presence of CRP, IL‐6, IL‐8, TNF‐alpha, sICAM‐1, and sTNF‐R75 in EBC. Albumin was found in two EBC samples of asthmatic children. We conclude that exhaled NO had a better correlation with lung function parameters and asthma control than exhaled CO and acidity of EBC, in mild to moderate persistent childhood asthma. However, exhaled NO, CO, and deaerated pH of EBC did not differ between asthmatic children and controls, possibly because of a too homogeneous and well‐controlled study population. To further evaluate the clinical utility of exhaled markers in monitoring childhood asthma, more studies are required on a wider range of asthma severity, and preferably with repeated measurements of markers and of asthma control. Pediatr Pulmonol. 2004; 38:107–114.
- 16 June 2004
- Published by Wiley in Pediatric Pulmonology
- Vol. 38 (2) , 107-114
Childhood asthma: Exhaled markers of airway inflammation, asthma control score, and lung function tests
Exhaled markers of airway inflammation become increasingly important in the management of childhood asthma. The aims of the present study are: 1) to compare exhaled markers of inflammation (nitric oxide, carbon monoxide, and acidity of breath condensate) with conventional asthma measures (lung function tests and asthma control score) in childhood asthma; and 2) to investigate the detectability of albumin, CRP, IL‐6, IL‐8, TNF‐alpha, sICAM‐1, and sTNF‐R75 in the exhaled breath condensate (EBC) of asthmatic children. Thirty‐two children with mild to moderate persistent asthma and healthy controls aged 6–12 years were studied. We measured exhaled NO and CO, and subsequently EBC was collected. Inflammatory mediators in EBC were measured using an enzyme‐linked immunosorbent assay. Respiratory symptoms and asthma control were assessed using the asthma control questionnaire (ACQ) of Juniper et al. (Eur Respir J 1999;14:902–907). Exhaled NO showed a significant correlation with exhaled CO (r = 0.59,P < 0.05) and FEV1(r = −0.59,P < 0.05), but not with ACQ score (r = 0.48,P = 0.06). Exhaled CO was correlated with prebronchodilator FEV1(r = −0.45,P < 0.05), but not with asthma control (r = 0.18,P = 0.35). Acidity of EBC was significantly lower in asthmatic children than in healthy controls (P < 0.05), but did not correlate with any of the conventional asthma measures. We were not able to demonstrate the presence of CRP, IL‐6, IL‐8, TNF‐alpha, sICAM‐1, and sTNF‐R75 in EBC. Albumin was found in two EBC samples of asthmatic children. We conclude that exhaled NO had a better correlation with lung function parameters and asthma control than exhaled CO and acidity of EBC, in mild to moderate persistent childhood asthma. However, exhaled NO, CO, and deaerated pH of EBC did not differ between asthmatic children and controls, possibly because of a too homogeneous and well‐controlled study population. To further evaluate the clinical utility of exhaled markers in monitoring childhood asthma, more studies are required on a wider range of asthma severity, and preferably with repeated measurements of markers and of asthma control. Pediatr Pulmonol. 2004; 38:107–114.
- 1 February 2004
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 15 (1) , 4-19
Exhaled breath condensate in children: Pearls and pitfalls
Exhaled breath condensate (EBC) is a rapidly growing field of research in respiratory medicine. Airway inflammation is a central feature of chronic lung diseases, like asthma, cystic fibrosis, bronchopulmonary dysplasia and primary ciliary dyskinesia. EBC may be a useful technique for non‐invasive assessment of markers of airway inflammation. The non‐invasive character of EBC ‘inflammometry’ and the general lack of appropriate techniques makes it particularly interesting for paediatrics.We provide a detailed update on the methods currently used for EBC collection and measurement of mediators. We emphasize on paediatric data. The apparent simplicity of the EBC method must not be overstated, as numerous methodological pitfalls have yet to overcome. Comparison and interpretation of data on this rapidly growing field of research is mainly hampered by the lack of standardization and the lack of specific high‐sensitivity immunochemical or colorimetric assays. The initiative of the European Respiratory Society to institute a task force on this topic is a first step towards a uniform technique of EBC. Meanwhile, when using this technique or when interpreting research data, one should be fully aware of the possible methodological pitfalls.
- 1 February 2004
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 15 (1) , 4-19
Exhaled breath condensate in children: Pearls and pitfalls
Exhaled breath condensate (EBC) is a rapidly growing field of research in respiratory medicine. Airway inflammation is a central feature of chronic lung diseases, like asthma, cystic fibrosis, bronchopulmonary dysplasia and primary ciliary dyskinesia. EBC may be a useful technique for non‐invasive assessment of markers of airway inflammation. The non‐invasive character of EBC ‘inflammometry’ and the general lack of appropriate techniques makes it particularly interesting for paediatrics.We provide a detailed update on the methods currently used for EBC collection and measurement of mediators. We emphasize on paediatric data. The apparent simplicity of the EBC method must not be overstated, as numerous methodological pitfalls have yet to overcome. Comparison and interpretation of data on this rapidly growing field of research is mainly hampered by the lack of standardization and the lack of specific high‐sensitivity immunochemical or colorimetric assays. The initiative of the European Respiratory Society to institute a task force on this topic is a first step towards a uniform technique of EBC. Meanwhile, when using this technique or when interpreting research data, one should be fully aware of the possible methodological pitfalls.
- 1 January 2001
- Vol. 12 (3) , 273-82
Phenotypic variability of the cat eye syndrome. Case report and review of the literature.
We present a male infant with preauricular skin tags and pits, downslanting palpebral fissures, hypertelorism, ectopic anus, hypospadias, and hypoplastic left heart syndrome. The clinical features in our patient show phenotypic overlap with the cat eye syndrome, as illustrated by the review of 105 reported cases. Cytogenetic analysis revealed a supernumerary marker chromosome, which was identified by microdissection and fluorescence in situ hybridization as an isodicentric chromosome 22(pter --> q11.2::q11.2 --> pter). It was proved with probes specific for the cat eye syndrome critical region that this region was present in quadruplicate in the propositus. We conclude that CES is characterized by large phenotypic variability, ranging from near normal to severe malformations, as reflected in the neurodevelopmental outcome. Preauricular skin tags and/or pits are the most consistent features, and suggest the presence of a supernumerary bisatellited marker chromosome 22 derived from duplication of the CES critical region.
- 1 January 2001
- Vol. 12 (3) , 273-82
Phenotypic variability of the cat eye syndrome. Case report and review of the literature.
We present a male infant with preauricular skin tags and pits, downslanting palpebral fissures, hypertelorism, ectopic anus, hypospadias, and hypoplastic left heart syndrome. The clinical features in our patient show phenotypic overlap with the cat eye syndrome, as illustrated by the review of 105 reported cases. Cytogenetic analysis revealed a supernumerary marker chromosome, which was identified by microdissection and fluorescence in situ hybridization as an isodicentric chromosome 22(pter --> q11.2::q11.2 --> pter). It was proved with probes specific for the cat eye syndrome critical region that this region was present in quadruplicate in the propositus. We conclude that CES is characterized by large phenotypic variability, ranging from near normal to severe malformations, as reflected in the neurodevelopmental outcome. Preauricular skin tags and/or pits are the most consistent features, and suggest the presence of a supernumerary bisatellited marker chromosome 22 derived from duplication of the CES critical region.