GFGlen E. J. Forton

Glen E. J. Forton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Glen E. J. Forton has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Middle Ear Reconstruction Using the Titanium Kurz Variac Partial Ossicular Replacement Prosthesis

    by Jeroen Meulemans, Floris L. Wuyts, Glen E. J. Forton

    In ossicular chain reconstruction, maximal rehabilitation of conductive hearing loss is the ultimate goal. Success mainly depends on the total eradication of disease, good aeration of the middle ear, and a stable connection between the tympanic membrane and the stapes, which in turn is highly dependent on the characteristics of the prosthesis used.1 Ideally, the ossicular reconstruction prosthesis should be safe, biocompatible, easy to handle, capable of efficient sound transmission, and have a low extrusion rate.2 Over the years, a variety of materials, including gold, ceramic, polyethylene, and hydroxyapatite prostheses, have been used. Because of its excellent biocompatibility, light weight, and tensile strength, titanium was introduced as a new material for ossiculoplasty in 1993. Since then, titanium prostheses have been used for ossicular reconstruction, in the form of either a partial ossicular replacement prosthesis (PORP) or a total ossicular replacement prosthesis (TORP). In 1999, Stupp and colleagues3 were the first to report a satisfactory functional outcome after titanium ossiculoplasty. Since then, several authors using different titanium prostheses (eg, Open Tübingen, Spiggle & Theis, Kurz) have reported good hearing results with a postoperative air-bone gap (ABG) lower than 20 dB in 43.8% to 89% of cases and extrusion rates of 5.2% or lower, illustrating the superior biocompatibility of these prostheses.4-10 However, many studies fail to report long-term follow-up and include results of both total and partial prostheses in the same study. In this series, only the Kurz TTP-Variac System PORP (Kurz GmbH) was used. The aim of the present study was to examine the ability of the Kurz TTP-Variac System PORP to restore ossicular continuity resulting in functional improvement, as well as to assess the safety of said prosthesis. Functional gain, postoperative ABG, improvement in ABG, and rate of successful postoperative hearing in the overall study population and in several subgroups (absent vs present malleus, wet vs dry preoperative condition of the ear, primary vs revision procedures, canal wall–down [CWD] vs canal wall–up [CWU] procedures, and chronic otitis media with cholesteatoma vs chronic otitis media without cholesteatoma vs ossicular chain disruption without presence of inflammatory disease) were calculated and compared. The rate of complications (prosthesis extrusion, prosthesis dislocation, recurrent perforation of the tympanic membrane, sensorineural hearing loss [SNHL], and recurrence of cholesteatoma) was determined.


  • CO2 Laser-Assisted Stapedotomy Combined With àWengen Titanium Clip Stapes Prosthesis

    by Glen E. J. Forton, Floris L. Wuyts, Kathelijne G. Delsupehe, Jan Verfaillie, Robert Loncke

    To report on the short-term results of CO2-laser assisted stapedotomy combined with the àWengen titanium clip stapes prosthesis. A comparison with published series using other prostheses and/or different stapedotomy techniques is made. Retrospective case series. Patients with a history and audiologic data matching stapes fixation and computed tomographic imaging excluding other anomalies such as malleus fixation, dehiscent superior semicircular canal, and large vestibular aqueduct that may mimic stapes fixation-like hearing loss. All patients underwent CO2 laser-assisted stapedotomy (Lumenis Co. Israel CO2 laser, Acuspot 712, SurgiTouch 870 scanner) and subsequent reconstruction by means of the àWengen titanium clip stapes prosthesis by Heinz Kurz Medizintechnik GmbH (Germany). Comparison and statistical analysis of preoperative and postoperative audiologic data. Sixty-two stapedotomies were performed (61 patients) using the CO2 laser and àWengen titanium clip stapes prosthesis. The mean postoperative air-bone gap 3 months postoperatively was 5.1 +/- 0.5 dB (standard deviation [SD], 4.1 dB; 0.5, 1, 2, 4 kHz). Air-bone gap closure less than or equal to 10 dB was achieved in 54 cases (87%). Air-bone gap closure less than 20 dB was achieved in all cases. The average gain was 27.8 +/- 1.5 dB (SD, 12 dB; 0.5, 1, 2, 4 kHz). The average bone-conduction threshold shift or "overclosure" on 2,000 Hz was 13.6 +/- 1.3 dB (SD, 10 dB). There was no postoperative perceptive hearing loss exceeding 15 dB on any measured frequency. The Amsterdam Hearing Evaluation Plots have also been used to evaluate our data. These data were statistically analyzed and compare favorably to other published series. The authors conclude that the combination of CO2 laser-assisted stapedotomy and the àWengen titanium clip stapes prosthesis is a combination likely to yield superior results in experienced hands.