Joseph Lardies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joseph Lardies has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Najib Kacem
Université Marie et Louis Pasteur
3 shared publications Gilles Bourbon
FEMTO–ST Institute, DMA, BFC University, 25000 Besançon, France
2 shared publicationsMarc Berthillier
Institute FEMTO-ST, DMA, UMR CNRS 6174
2 shared publicationsPatrice Le Moal
FEMTO–ST Institute, DMA, BFC University, 25000 Besançon, France
2 shared publicationsVincent Walter
FEMTO–ST Institute, DMA, BFC University, 25000 Besançon, France
2 shared publicationsZaka Ratsimalahelo
C.R.E.S.E , University of Franche-Comté , Besançon, France
2 shared publications
Latest Publications
- Open Access
- 19 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 1084
Nonlinear Analytical Model of Two Weakly Coupled MEMS Cantilevers for Mass Sensing Using Electrostatic Actuation
This paper presents a nonlinear analytical model of MEMS mass sensor, which is composed of two cantilevers of 98 µm and 100 µm length, 20 µm width and 1.3 µm thick. They are connected by a coupling beam and only the shortest cantilever is actuated by a combined AC-DC voltage. The DC voltage is used to equilibrate the system and the phenomenon of mode localization is investigated when a mass perturbation is applied. The sensor is modeled as a continuous system with beam theory and non-ideal boundary conditions are considered by using flexible supports. With a low AC voltage of 10 mV, a DC voltage of 5.85 V can counterbalance the length difference. This DC voltage decreases at 5.60 V when we increase the AC voltage, due to the effect of electrostatic nonlinearities. For a relative added mass of 0.1%, the amplitude change in the two cantilevers is more important when the coupling is weaker.
- 19 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 1084
Open AccessNonlinear Analytical Model of Two Weakly Coupled MEMS Cantilevers for Mass Sensing Using Electrostatic Actuation
This paper presents a nonlinear analytical model of MEMS mass sensor, which is composed of two cantilevers of 98 µm and 100 µm length, 20 µm width and 1.3 µm thick. They are connected by a coupling beam and only the shortest cantilever is actuated by a combined AC-DC voltage. The DC voltage is used to equilibrate the system and the phenomenon of mode localization is investigated when a mass perturbation is applied. The sensor is modeled as a continuous system with beam theory and non-ideal boundary conditions are considered by using flexible supports. With a low AC voltage of 10 mV, a DC voltage of 5.85 V can counterbalance the length difference. This DC voltage decreases at 5.60 V when we increase the AC voltage, due to the effect of electrostatic nonlinearities. For a relative added mass of 0.1%, the amplitude change in the two cantilevers is more important when the coupling is weaker.
- Open Access
- 5 November 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (11) , 575
Investigations of the Effects of Geometric Imperfections on the Nonlinear Static and Dynamic Behavior of Capacitive Micomachined Ultrasonic Transducers
In order to investigate the effects of geometric imperfections on the static and dynamic behavior of capacitive micomachined ultrasonic transducers (CMUTs), the governing equations of motion of a circular microplate with initial defection have been derived using the von Kármán plate theory while taking into account the mechanical and electrostatic nonlinearities. The partial differential equations are discretized using the differential quadrature method (DQM) and the resulting coupled nonlinear ordinary differential equations (ODEs) are solved using the harmonic balance method (HBM) coupled with the asymptotic numerical method (ANM). It is shown that the initial deflection has an impact on the static behavior of the CMUT by increasing its pull-in voltage up to 45%. Moreover, the dynamic behavior is affected by the initial deflection, enabling an increase in the resonance frequencies and the bistability domain and leading to a change of the frequency response from softening to hardening. This model allows MEMS designers to predict the nonlinear behavior of imperfect CMUT and tune its bifurcation topology in order to enhance its performances in terms of bandwidth and generated acoustic power while driving the microplate up to 80% beyond its critical amplitude.
- 5 November 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (11) , 575
Open AccessInvestigations of the Effects of Geometric Imperfections on the Nonlinear Static and Dynamic Behavior of Capacitive Micomachined Ultrasonic Transducers
In order to investigate the effects of geometric imperfections on the static and dynamic behavior of capacitive micomachined ultrasonic transducers (CMUTs), the governing equations of motion of a circular microplate with initial defection have been derived using the von Kármán plate theory while taking into account the mechanical and electrostatic nonlinearities. The partial differential equations are discretized using the differential quadrature method (DQM) and the resulting coupled nonlinear ordinary differential equations (ODEs) are solved using the harmonic balance method (HBM) coupled with the asymptotic numerical method (ANM). It is shown that the initial deflection has an impact on the static behavior of the CMUT by increasing its pull-in voltage up to 45%. Moreover, the dynamic behavior is affected by the initial deflection, enabling an increase in the resonance frequencies and the bistability domain and leading to a change of the frequency response from softening to hardening. This model allows MEMS designers to predict the nonlinear behavior of imperfect CMUT and tune its bifurcation topology in order to enhance its performances in terms of bandwidth and generated acoustic power while driving the microplate up to 80% beyond its critical amplitude.
- 1 January 2017
- Published by EDP Sciences in Mechanics & Industry
- Vol. 18 (7) , 702
Modal parameter identification of a CMUT membrane using response data only
Capacitive micromachined ultrasonic transducers (CMUTs) are microelectromechanical systems used for the generation of ultrasounds. The fundamental element of the transducer is a clamped thin metallized membrane that vibrates under voltage variations. To control such oscillations and to optimize its dynamic response it is necessary to know the modal parameters of the membrane such as resonance frequency, damping and stiffness coefficients. The purpose of this work is to identify these parameters using only the time data obtained from the membrane center displacement. Dynamic measurements are conducted in time domain and we use two methods to identify the modal parameters: a subspace method based on an innovation model of the state-space representation and the continuous wavelet transform method based on the use of the ridge of the wavelet transform of the displacement. Experimental results are presented showing the effectiveness of these two procedures in modal parameter identification.
- 1 January 2017
- Published by EDP Sciences in Mechanics & Industry
- Vol. 18 (7) , 702
Modal parameter identification of a CMUT membrane using response data only
Capacitive micromachined ultrasonic transducers (CMUTs) are microelectromechanical systems used for the generation of ultrasounds. The fundamental element of the transducer is a clamped thin metallized membrane that vibrates under voltage variations. To control such oscillations and to optimize its dynamic response it is necessary to know the modal parameters of the membrane such as resonance frequency, damping and stiffness coefficients. The purpose of this work is to identify these parameters using only the time data obtained from the membrane center displacement. Dynamic measurements are conducted in time domain and we use two methods to identify the modal parameters: a subspace method based on an innovation model of the state-space representation and the continuous wavelet transform method based on the use of the ridge of the wavelet transform of the displacement. Experimental results are presented showing the effectiveness of these two procedures in modal parameter identification.
- Open Access
- 2 November 2015
- Published by Hindawi Limited in Shock and Vibration
- Vol. 2015, 1-10
Modal Parameter Identification from Output Data Only: Equivalent Approaches
The problem of modal parameter identification from output data only is presented. To identify the modal parameters different algorithms are presented: the block Hankel matrix and its shifted version and the block observability and block controllability matrices and their shifted version. These algorithms are derived from properties of the subspace approach. It is shown in the paper that these algorithms give the same results even in the noisy data case. Numerical and experimental results are presented showing the effectiveness of the procedure. In particular a microsystem constituted of a perforated microplate is analysed. The problem of modal parameter identification from output data only is presented. To identify the modal parameters different algorithms are presented: the block Hankel matrix and its shifted version and the block observability and block controllability matrices and their shifted version. These algorithms are derived from properties of the subspace approach. It is shown in the paper that these algorithms give the same results even in the noisy data case. Numerical and experimental results are presented showing the effectiveness of the procedure. In particular a microsystem constituted of a perforated microplate is analysed.
- 2 November 2015
- Published by Hindawi Limited in Shock and Vibration
- Vol. 2015, 1-10
Open AccessModal Parameter Identification from Output Data Only: Equivalent Approaches
The problem of modal parameter identification from output data only is presented. To identify the modal parameters different algorithms are presented: the block Hankel matrix and its shifted version and the block observability and block controllability matrices and their shifted version. These algorithms are derived from properties of the subspace approach. It is shown in the paper that these algorithms give the same results even in the noisy data case. Numerical and experimental results are presented showing the effectiveness of the procedure. In particular a microsystem constituted of a perforated microplate is analysed. The problem of modal parameter identification from output data only is presented. To identify the modal parameters different algorithms are presented: the block Hankel matrix and its shifted version and the block observability and block controllability matrices and their shifted version. These algorithms are derived from properties of the subspace approach. It is shown in the paper that these algorithms give the same results even in the noisy data case. Numerical and experimental results are presented showing the effectiveness of the procedure. In particular a microsystem constituted of a perforated microplate is analysed.
- 14 July 2015
- Published by Springer Nature in Microsystem Technologies
- Vol. 22 (3) , 593-601
Characterization of capacitive micromachined ultrasonic transducers
- 14 July 2015
- Published by Springer Nature in Microsystem Technologies
- Vol. 22 (3) , 593-601
Characterization of capacitive micromachined ultrasonic transducers
- Open Access
- 28 January 2015
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 20, 01002
Modal parameter identification from output data only
To identify the modal parameters of a vibrating system from output data only we use a state space model and usually two approaches are considered: the block Hankel matrix and its shifted version and the block observability matrix and its shifted version. It is shown in the communication that these two approaches give the same results even in the noisy data case. We present numerical and experimental results, who prove the effectiveness of the procedure.
- 28 January 2015
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 20, 01002
Open AccessModal parameter identification from output data only
To identify the modal parameters of a vibrating system from output data only we use a state space model and usually two approaches are considered: the block Hankel matrix and its shifted version and the block observability matrix and its shifted version. It is shown in the communication that these two approaches give the same results even in the noisy data case. We present numerical and experimental results, who prove the effectiveness of the procedure.
- Open Access
- 1 July 2010
- Published by EDP Sciences in International Journal for Simulation and Multidisciplinary Design Optimization
- Vol. 4 (3-4) , 135-140
Localization of Radiating Sources by an Acoustical Array
- 1 July 2010
- Published by EDP Sciences in International Journal for Simulation and Multidisciplinary Design Optimization
- Vol. 4 (3-4) , 135-140
Open AccessLocalization of Radiating Sources by an Acoustical Array
- 10 April 2009
- Published by Springer Nature in Archive of Applied Mechanics
- Vol. 80 (4) , 335-352
Modal parameter identification based on ARMAV and state–space approaches
- 10 April 2009
- Published by Springer Nature in Archive of Applied Mechanics
- Vol. 80 (4) , 335-352
Modal parameter identification based on ARMAV and state–space approaches
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3647
Influence of the shape of the membrane of computed cMUT using FEA/BEM analysis
The possibility to excite and detectacoustic waves in fluids using capacitive micro‐machined ultrasonic transducers (cMUT) built on silicon using clean room techniques offers attractive opportunities for manufacturing high quality low cost imaging probes. CMUTs developed for acoustic imaging exploit the first flexural mode of thin and stiff membranes, leading to bandwidth larger than 100%. These transducers can be accurately designed using mixed finite element analysis/boundary element methods (FEA/BEM). Periodic FEA particularly allows for the simulation of devices exhibiting complicated shape interfaces and involving materials of different nature. BEM also are particularly well‐suited to provide an accurate description of any stacked medium assuming flat interfaces for the radiation area and the layer interface for 2 and 3D structures as well. In this work, we have analysed the influence of the shape of the MUT membrane on the spectral response of the transducer. 3D Computations have been conducted considering radiation coniditions in the substrate on the backside (silicon) and in viscous water on the front side. we have particularly focused the computation on solutions allowing for reducing parasitic modes in the actual operation of the transducer. The efficiency of the different configuration are compared in termes of emitted pressure contributions.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 3647
Influence of the shape of the membrane of computed cMUT using FEA/BEM analysis
The possibility to excite and detectacoustic waves in fluids using capacitive micro‐machined ultrasonic transducers (cMUT) built on silicon using clean room techniques offers attractive opportunities for manufacturing high quality low cost imaging probes. CMUTs developed for acoustic imaging exploit the first flexural mode of thin and stiff membranes, leading to bandwidth larger than 100%. These transducers can be accurately designed using mixed finite element analysis/boundary element methods (FEA/BEM). Periodic FEA particularly allows for the simulation of devices exhibiting complicated shape interfaces and involving materials of different nature. BEM also are particularly well‐suited to provide an accurate description of any stacked medium assuming flat interfaces for the radiation area and the layer interface for 2 and 3D structures as well. In this work, we have analysed the influence of the shape of the MUT membrane on the spectral response of the transducer. 3D Computations have been conducted considering radiation coniditions in the substrate on the backside (silicon) and in viscous water on the front side. we have particularly focused the computation on solutions allowing for reducing parasitic modes in the actual operation of the transducer. The efficiency of the different configuration are compared in termes of emitted pressure contributions.
- 1 October 2005
- Published by Taylor & Francis in Communications in Statistics - Simulation and Computation
- Vol. 34 (4) , 863-877
Model Order Estimation of a Multivariable Stochastic Process
This article presents a procedure allowing us to estimate the minimal order of a state-space representation, for a multivariable stochastic process, from a sequence of observations. The method proposes a statistical rule for testing the rank of a block Hankel matrix of data, since this rank is related to the order of the process. A new information criterion is then developed and used to decide upon the order of the model. In this article we generalize the Aoki C-test. Using two representative data sets as the basis for a Monte Carlo experiment and real data based on Danish economy, we estimate the order of multivariable stochastic processes.
- 1 October 2005
- Published by Taylor & Francis in Communications in Statistics - Simulation and Computation
- Vol. 34 (4) , 863-877
Model Order Estimation of a Multivariable Stochastic Process
This article presents a procedure allowing us to estimate the minimal order of a state-space representation, for a multivariable stochastic process, from a sequence of observations. The method proposes a statistical rule for testing the rank of a block Hankel matrix of data, since this rank is related to the order of the process. A new information criterion is then developed and used to decide upon the order of the model. In this article we generalize the Aoki C-test. Using two representative data sets as the basis for a Monte Carlo experiment and real data based on Danish economy, we estimate the order of multivariable stochastic processes.