Guang-Jing Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guang-Jing Xiong has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Jian Yang
College of Civil Engineering and Architecture, China Three Gorges University; No. 8, Daxue Road, Yichang 443002
1 shared publicationQi-Fei Yang
Shantou University
1 shared publicationX. Ma
Professor, Dept. of Civil Engineering, Shantou Univ., Shantou 515063, P.R. China
1 shared publicationXiao-Hua Lu
Shantou University
1 shared publication- Xiaoyong Wu
Chief, Project Department, Shijiazhuang Hongye Traffic Construction Supervision Co. LTD, Shijiazhuang, China
1 shared publication Z. Ji
Professor, Dept. of Civil Engineering, Shantou Univ., Shantou 515063, P.R. China
1 shared publication
Latest Publications
- 25 July 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 12-16
A Method for Measuring Average Strain of Cracked Ferrocement Plates
To measure the average stain of cracked ferrocement plates under bending successfully, thin and flexible copper foils were bonded to the plate surface before the strain gauges. A complete load-strain curve of ferrocement under bending was obtained by using this measuring method. Through conversion, the crack width was approximately estimated by reflecting the bending strain. The initial crack width, the ultimate crack width and the load-crack width curves could be acquired. Both the load-displacement curve and the load-strain curve show that ferrocement plate had good performance in energy absorption and flexural strength.
- 25 July 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 12-16
A Method for Measuring Average Strain of Cracked Ferrocement Plates
To measure the average stain of cracked ferrocement plates under bending successfully, thin and flexible copper foils were bonded to the plate surface before the strain gauges. A complete load-strain curve of ferrocement under bending was obtained by using this measuring method. Through conversion, the crack width was approximately estimated by reflecting the bending strain. The initial crack width, the ultimate crack width and the load-crack width curves could be acquired. Both the load-displacement curve and the load-strain curve show that ferrocement plate had good performance in energy absorption and flexural strength.
- 17 April 2010
- Published by Springer Nature in Journal of Central South University of Technology
- Vol. 17 (2) , 400-405
Double pull specimen more suitable for measuring bond-slip relationship of FRP-to-concrete interface
- 17 April 2010
- Published by Springer Nature in Journal of Central South University of Technology
- Vol. 17 (2) , 400-405
Double pull specimen more suitable for measuring bond-slip relationship of FRP-to-concrete interface
- 1 June 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 10 (3) , 275-278
Effect of Contact Pressure on Bond Strength of Fiber-Reinforced Polymer to Concrete
In this technical note, the importance of contact pressure ( 0.03 N/ ) during curing of adhesive between fiber reinforced polymer (FRP) and concrete is addressed. The shortcoming of fast-curing epoxy resin is pointed out. Different pressures and an ordinary epoxy resin were chosen to assess the effectiveness of contact pressure on FRP-to-concrete bond strength. The test results showed that the bond quality could be significantly improved by exerting a contact pressure 0.01 N/ . A simple and easy site-operation method for exerting contact pressure is also introduced.- 1 June 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 10 (3) , 275-278
Effect of Contact Pressure on Bond Strength of Fiber-Reinforced Polymer to Concrete
In this technical note, the importance of contact pressure ( 0.03 N/ ) during curing of adhesive between fiber reinforced polymer (FRP) and concrete is addressed. The shortcoming of fast-curing epoxy resin is pointed out. Different pressures and an ordinary epoxy resin were chosen to assess the effectiveness of contact pressure on FRP-to-concrete bond strength. The test results showed that the bond quality could be significantly improved by exerting a contact pressure 0.01 N/ . A simple and easy site-operation method for exerting contact pressure is also introduced.