Chen-Ching Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chen-Ching Liu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Bruce M. Howe
Ocean and Resources Eng., Univ. of Hawaii at Manoa, 2540 Dole St., Holmes Hall 402, Honolulu, HI 96822
1 shared publication - Chee-Wooi Ten
Department of Electrical and Computer Engineering, Michigan Technological University, Houghton, MI, USA
1 shared publication - Manimaran Govindarasu
Iowa State University
1 shared publication - Ting Chan
Student Member, IEEE, Department of Electrical Engineering, University of Washington, Seattle, WA 98195-2500 USA
1 shared publication
Latest Publications
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1
Strengthening Our Capacity to Educate Power Engineers
This is a summary of the presentation in the panel session "Power Industry Workforce of the Future" for the 2007 IEEE PES General Meeting in Tampa, Florida.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1
Strengthening Our Capacity to Educate Power Engineers
This is a summary of the presentation in the panel session "Power Industry Workforce of the Future" for the 2007 IEEE PES General Meeting in Tampa, Florida.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (19325517) , 1-6
Optimization Based Load Management for the NEPTUNE Power System
The objective of the North-East Pacific Time-Series Undersea Networked Experiment (NEPTUNE) program is to construct an underwater cabled observatory on the floor of the Pacific Ocean. While the goal is to provide as much power as possible to users of the system, the system conditions need to be monitored on line in order to determine whether or not any corrective action is needed. Due to the unique nature of the underwater observatory system and load characteristics, an analytical tool is needed to calculate the optimal operating condition that serves the maximum number of loads while satisfying all the constraints. In this paper, an optimization based load management algorithm is presented. The method takes into account all system constraints as well as priorities of the loads.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (19325517) , 1-6
Optimization Based Load Management for the NEPTUNE Power System
The objective of the North-East Pacific Time-Series Undersea Networked Experiment (NEPTUNE) program is to construct an underwater cabled observatory on the floor of the Pacific Ocean. While the goal is to provide as much power as possible to users of the system, the system conditions need to be monitored on line in order to determine whether or not any corrective action is needed. Due to the unique nature of the underwater observatory system and load characteristics, an analytical tool is needed to calculate the optimal operating condition that serves the maximum number of loads while satisfying all the constraints. In this paper, an optimization based load management algorithm is presented. The method takes into account all system constraints as well as priorities of the loads.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-8
Vulnerability Assessment of Cybersecurity for SCADA Systems Using Attack Trees
By penetrating the SCADA system, an intruder may remotely operate a power system using supervisory control privileges. Hence, cybersecurity has been recognized as a major threat due to the potential intrusion to the online system. This paper proposes a methodology to evaluate the cybersecurity vulnerability using attack trees. The attack tree formulation based on power system control networks is used to evaluate the system, scenario, and leaf vulnerabilities. The measure of vulnerabilities in the power system control framework is determined based on existing cybersecurity conditions before the vulnerability indices are evaluated. After the indices are evaluated, an upper bound is imposed on each scenario vulnerability in order to determine the pivotal attack leaves that require countermeasure improvements. The proposed framework can be extended to security investment analysis.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-8
Vulnerability Assessment of Cybersecurity for SCADA Systems Using Attack Trees
By penetrating the SCADA system, an intruder may remotely operate a power system using supervisory control privileges. Hence, cybersecurity has been recognized as a major threat due to the potential intrusion to the online system. This paper proposes a methodology to evaluate the cybersecurity vulnerability using attack trees. The attack tree formulation based on power system control networks is used to evaluate the system, scenario, and leaf vulnerabilities. The measure of vulnerabilities in the power system control framework is determined based on existing cybersecurity conditions before the vulnerability indices are evaluated. After the indices are evaluated, an upper bound is imposed on each scenario vulnerability in order to determine the pivotal attack leaves that require countermeasure improvements. The proposed framework can be extended to security investment analysis.