Johnny Wong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Johnny Wong has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- JungHwan Oh
Department of Computer Science and Engineering, University of North Texas, Denton, TX 76203, U.S.A.
8 shared publications - Piet C. de Groen
Mayo Clinic College of Medicine, Rochester, MN 55905, U.S.A.
8 shared publications Wallapak Tavanapong
Computer Science Department, Iowa State University, Ames, IA 50011, U.S.A.
8 shared publicationsFelicity Enders
5 shared publicationsMichael J. Szewczynski
5 shared publications- Wallapak Tavanapong
Department of Computer Science, Iowa State University, Ames, IA 50011, USA
5 shared publications
Latest Publications
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Detection of ulcerative colitis severity in colonoscopy video frames
Ulcerative colitis (UC) is a chronic inflammatory disease characterized by periods of relapses and remissions affecting more than 500,000 people in the United States. The therapeutic goals of UC are to first induce and then maintain disease remission. However, it is very difficult to evaluate the severity of UC objectively because of non-uniform nature of symptoms associated with UC, and large variations in their patterns. To address this, we objectively measure and classify the severity of UC presented in optical colonoscopy video frames based on the image textures. To extract distinct textures, we are using a hybrid approach in which a new proposed feature based on the accumulation of pixel value differences is combined with an existing feature such as LBP (Local Binary Pattern). The experimental results show the hybrid method can achieve more than 90% overall accuracy.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Detection of ulcerative colitis severity in colonoscopy video frames
Ulcerative colitis (UC) is a chronic inflammatory disease characterized by periods of relapses and remissions affecting more than 500,000 people in the United States. The therapeutic goals of UC are to first induce and then maintain disease remission. However, it is very difficult to evaluate the severity of UC objectively because of non-uniform nature of symptoms associated with UC, and large variations in their patterns. To address this, we objectively measure and classify the severity of UC presented in optical colonoscopy video frames based on the image textures. To extract distinct textures, we are using a hybrid approach in which a new proposed feature based on the accumulation of pixel value differences is combined with an existing feature such as LBP (Local Binary Pattern). The experimental results show the hybrid method can achieve more than 90% overall accuracy.
- 11 June 2014
- Published by Elsevier in Neurocomputing
- Vol. 144, 70-91
Abnormal image detection in endoscopy videos using a filter bank and local binary patterns
- 11 June 2014
- Published by Elsevier in Neurocomputing
- Vol. 144, 70-91
Abnormal image detection in endoscopy videos using a filter bank and local binary patterns
- 1 January 2014
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 38 (1) , 22-33
3D Reconstruction of virtual colon structures from colonoscopy images
- 1 January 2014
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 38 (1) , 22-33
3D Reconstruction of virtual colon structures from colonoscopy images
- 14 August 2013
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 112 (3) , 407-421
SAPPHIRE: A toolkit for building efficient stream programs for medical video analysis
- 14 August 2013
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 112 (3) , 407-421
SAPPHIRE: A toolkit for building efficient stream programs for medical video analysis
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77 (5) , AB500
Tu1324 Automated, Real-Time Feedback During Colonoscopy Improves Endoscopist Technique As Intended: a Controlled Clinical Trial
- 1 May 2013
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 77 (5) , AB500
Tu1324 Automated, Real-Time Feedback During Colonoscopy Improves Endoscopist Technique As Intended: a Controlled Clinical Trial
- 1 May 2013
- Published by Elsevier in Gastroenterology
- Vol. 144 (5)
73 Automated, Objective Measurements of Colonoscopy Technique: A Comparison Between Trainees and Staff
- 1 May 2013
- Published by Elsevier in Gastroenterology
- Vol. 144 (5)
73 Automated, Objective Measurements of Colonoscopy Technique: A Comparison Between Trainees and Staff
- 12 June 2012
- Published by SAGE Publications in Journal of Computer Security
- Vol. 20 (2-3) , 169-198
Towards cost-sensitive assessment of intrusion response selection
In recent years, cost-sensitive intrusion response has gained significant interest mainly due to its emphasis on the balance between potential damage incurred by the intrusion and cost of the response. However, one of the challenges in applying this approach is defining consistent and adaptable measurements of these cost factors on the basis of requirements and policy of the system being protected against intrusions. In this paper we present a framework for the cost-sensitive selection of intrusion response. Specifically, we introduce a set of measurements that characterize potential costs associated with the intrusion handling process and propose evaluation method of intrusion response with respect to the risk of potential intrusion damage, effectiveness of response action and response cost for a system. We provide an implementation of the proposed solution as a plugin tool for Snort IDS and demonstrate its advantages on DARPA data set and real network traffic.
- 12 June 2012
- Published by SAGE Publications in Journal of Computer Security
- Vol. 20 (2-3) , 169-198
Towards cost-sensitive assessment of intrusion response selection
In recent years, cost-sensitive intrusion response has gained significant interest mainly due to its emphasis on the balance between potential damage incurred by the intrusion and cost of the response. However, one of the challenges in applying this approach is defining consistent and adaptable measurements of these cost factors on the basis of requirements and policy of the system being protected against intrusions. In this paper we present a framework for the cost-sensitive selection of intrusion response. Specifically, we introduce a set of measurements that characterize potential costs associated with the intrusion handling process and propose evaluation method of intrusion response with respect to the risk of potential intrusion damage, effectiveness of response action and response cost for a system. We provide an implementation of the proposed solution as a plugin tool for Snort IDS and demonstrate its advantages on DARPA data set and real network traffic.
- 1 May 2012
- Published by Elsevier in Gastroenterology
- Vol. 142 (5)
968 Principal Component Analysis Defines Two Sets of Endoscopic Features for Ulcerative Colitis
- 1 May 2012
- Published by Elsevier in Gastroenterology
- Vol. 142 (5)
968 Principal Component Analysis Defines Two Sets of Endoscopic Features for Ulcerative Colitis
- 1 May 2012
- Published by Elsevier in Gastroenterology
- Vol. 142 (5)
Sa1110 Will Real-Time Feedback Systems Adversely Affect Colonoscopy Practice?
- 1 May 2012
- Published by Elsevier in Gastroenterology
- Vol. 142 (5)
Sa1110 Will Real-Time Feedback Systems Adversely Affect Colonoscopy Practice?
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Do Endoscopists Who Participate in De-Identified Monitoring Provide Higher Quality Than Those Who Do Not?
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Do Endoscopists Who Participate in De-Identified Monitoring Provide Higher Quality Than Those Who Do Not?