Hiromi Tokura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiromi Tokura has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Takeshi Morita
Shizuoka University
4 shared publications - Tomoko Wakamura
Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
3 shared publications Ki-Ja Hyun
2 shared publications- Masayuki Kondo
Comprehensive Housing R&D Institute, Sekisui House, Ltd., Kyoto, Japan
2 shared publications Satoshi Tamotsu
2 shared publications- Tadashi Oishi
Graduate School of Humanities and Sciences, Nara Women's University, Nara, Japan; Kyousei Science Center for Life and Nature, Nara Women's University, Nara, Japan
2 shared publications
Latest Publications
- 1 March 2009
- Vol. 33 (1) , 193-9
Influences of twilight on diurnal variation of core temperature, its nadir, and urinary 6-hydroxymelatonin sulfate during nocturnal sleep and morning drowsiness.
This study aimed at elucidating the physiological significance of dusk and dawn in the circadian rhythm of core temperature (T(core)) and urinary 6-hydroxymelatonin sulfate in humans during sleep and the waking sensation just after rising. Seven female and four male students served as participants. Participants retired at 2300 h and rose at 0700 h. They were requested to sit on a chair and spend time as quietly as possible during wakefulness, reading a book or listening to recorded light music. Two lighting conditions were provided for each participant: 1) Light-Dark (LD)-rectangular light change with abrupt decrease from 3,000 lx to 100 lx at 1800 h, abrupt increase from 0 lx to 3,000 lx at 0700 h. 2) LD-twilight light change with gradual decrease from 3,000 lx to 100 lx starting at 1700 h (twilight period about 2 h), with gradual increase from 0 lx to 3,000 lx starting at 0500 h (twilight period about 2 h). The periods of 0 lx at night were from 2300 h to 0700 h on the first day and from 2300 to 0500 h on the second day. Nadir time advanced significantly under the influence of the LD-twilight condition. The amount of 6-hydroxymelatonin sulfate in urine collected at 0200 h was significantly higher under LD-twilight in comparison with LD-rectangular light. Morning drowsiness tended to be lower under LD-twilight. Our results suggest that in architectural design of indoor illumination it is important to provide LD-twilight in the evening and early morning for sleep promotion in healthy normal people and/or light treatment in elderly patients with advanced dementia.
- 1 March 2009
- Vol. 33 (1) , 193-9
Influences of twilight on diurnal variation of core temperature, its nadir, and urinary 6-hydroxymelatonin sulfate during nocturnal sleep and morning drowsiness.
This study aimed at elucidating the physiological significance of dusk and dawn in the circadian rhythm of core temperature (T(core)) and urinary 6-hydroxymelatonin sulfate in humans during sleep and the waking sensation just after rising. Seven female and four male students served as participants. Participants retired at 2300 h and rose at 0700 h. They were requested to sit on a chair and spend time as quietly as possible during wakefulness, reading a book or listening to recorded light music. Two lighting conditions were provided for each participant: 1) Light-Dark (LD)-rectangular light change with abrupt decrease from 3,000 lx to 100 lx at 1800 h, abrupt increase from 0 lx to 3,000 lx at 0700 h. 2) LD-twilight light change with gradual decrease from 3,000 lx to 100 lx starting at 1700 h (twilight period about 2 h), with gradual increase from 0 lx to 3,000 lx starting at 0500 h (twilight period about 2 h). The periods of 0 lx at night were from 2300 h to 0700 h on the first day and from 2300 to 0500 h on the second day. Nadir time advanced significantly under the influence of the LD-twilight condition. The amount of 6-hydroxymelatonin sulfate in urine collected at 0200 h was significantly higher under LD-twilight in comparison with LD-rectangular light. Morning drowsiness tended to be lower under LD-twilight. Our results suggest that in architectural design of indoor illumination it is important to provide LD-twilight in the evening and early morning for sleep promotion in healthy normal people and/or light treatment in elderly patients with advanced dementia.
- 1 June 2007
- Vol. 31 (2) , 587-93
Combined influences of gradual changes in room temperature and light around dusk and dawn on circadian rhythms of core temperature, urinary 6-hydroxymelatonin sulfate and waking sensation just after rising.
The present experiment aimed at knowing how a gradual changes of room temperature (T(a)) and light in the evening and early morning could influence circadian rhythms of core temperature (T(core)), skin temperatures, urinary 6-hydroxymelatonin sulfate and waking sensation just after rising in humans. Two kinds of room environment were provided for each participant: 1) Constant room temperature (T(a)) of 27 degrees C over the 24 h and LD-rectangular light change with abrupt decreasing from 3,000 lx to 100 lx at 1800, abrupt increasing from 0 lx to 3,000 lx at 0700. 2) Cyclic changes of T(a) and with gradual decrease from 3,000 lx to 100 lx onset at 1700 (twilight period about 2 h), with gradual increasing from 0 lx to 3,000 lx onset at 0500 (about 2 h). Main results are summarized as follows: 1) Circadian rhythms of nadir in the core temperature (T(core)) significantly advanced earlier under the influence of gradual changes of T(a) and light than no gradual changes of T(a) and light. 2) Nocturnal fall of T(core) and morning rise of T(core) were greater and quicker, respectively, under the influence of gradual changes of T(a) and light than no gradual changes of T(a) and light. 3) Urinary 6-hydroxymelatonin sulfate during nocturnal sleep was significantly greater under the influence of gradual changes of T(a) and light. 4) Waking sensation just after rising was significantly better under the influence of gradual changes of T(a) and light. We discussed these findings in terms of circadian and thermoregulatory physiology.
- 1 June 2007
- Vol. 31 (2) , 587-93
Combined influences of gradual changes in room temperature and light around dusk and dawn on circadian rhythms of core temperature, urinary 6-hydroxymelatonin sulfate and waking sensation just after rising.
The present experiment aimed at knowing how a gradual changes of room temperature (T(a)) and light in the evening and early morning could influence circadian rhythms of core temperature (T(core)), skin temperatures, urinary 6-hydroxymelatonin sulfate and waking sensation just after rising in humans. Two kinds of room environment were provided for each participant: 1) Constant room temperature (T(a)) of 27 degrees C over the 24 h and LD-rectangular light change with abrupt decreasing from 3,000 lx to 100 lx at 1800, abrupt increasing from 0 lx to 3,000 lx at 0700. 2) Cyclic changes of T(a) and with gradual decrease from 3,000 lx to 100 lx onset at 1700 (twilight period about 2 h), with gradual increasing from 0 lx to 3,000 lx onset at 0500 (about 2 h). Main results are summarized as follows: 1) Circadian rhythms of nadir in the core temperature (T(core)) significantly advanced earlier under the influence of gradual changes of T(a) and light than no gradual changes of T(a) and light. 2) Nocturnal fall of T(core) and morning rise of T(core) were greater and quicker, respectively, under the influence of gradual changes of T(a) and light than no gradual changes of T(a) and light. 3) Urinary 6-hydroxymelatonin sulfate during nocturnal sleep was significantly greater under the influence of gradual changes of T(a) and light. 4) Waking sensation just after rising was significantly better under the influence of gradual changes of T(a) and light. We discussed these findings in terms of circadian and thermoregulatory physiology.
- 1 March 2007
- Vol. 31 (1) , 145-51
Influence of two different light intensities from 16:00 to 20:30 hours on evening dressing behavior in the cold.
The present experiment tested our hypothesis that the subjects will wear more clothing in the evening cold under the influence of bright light exposure in the late afternoon and evening. Nine young female adults participated in this study. Light intensity was controlled from 9:00 h to 16:00 h at 100 lx, and from 16:00 h to 20:30 h either at 3000 lx in the bright light (Brighte) or at 10 lx in the dim light ("Dim") conditions. Light intensity was maintained at 10 lx from 20:30 h to 23:00 h. They were instructed to wear garments to maintain themselves to feel comfortable during the fall of ambient temperature from 30 degrees C to 15 degrees C (21:00 h - 22:00 h) and its constant temperature at 15 degrees C (22:00 h - 23:00 h). Most subjects dressed in heavier clothing in the "Bright" than in the "Dim" conditions. The evening fall of core temperature was significantly smaller and the urinary melatonin secretion was significantly lower in the "Bright" condition, suggesting that the set-point of core temperature has been set at a higher level during the evening and at night, being influenced by the less amount of melatonin secretion. Thus, it is concluded that the late afternoon and evening bright light exposure could accelerate the dressing behavior in the evening cold.
- 1 March 2007
- Vol. 31 (1) , 145-51
Influence of two different light intensities from 16:00 to 20:30 hours on evening dressing behavior in the cold.
The present experiment tested our hypothesis that the subjects will wear more clothing in the evening cold under the influence of bright light exposure in the late afternoon and evening. Nine young female adults participated in this study. Light intensity was controlled from 9:00 h to 16:00 h at 100 lx, and from 16:00 h to 20:30 h either at 3000 lx in the bright light (Brighte) or at 10 lx in the dim light ("Dim") conditions. Light intensity was maintained at 10 lx from 20:30 h to 23:00 h. They were instructed to wear garments to maintain themselves to feel comfortable during the fall of ambient temperature from 30 degrees C to 15 degrees C (21:00 h - 22:00 h) and its constant temperature at 15 degrees C (22:00 h - 23:00 h). Most subjects dressed in heavier clothing in the "Bright" than in the "Dim" conditions. The evening fall of core temperature was significantly smaller and the urinary melatonin secretion was significantly lower in the "Bright" condition, suggesting that the set-point of core temperature has been set at a higher level during the evening and at night, being influenced by the less amount of melatonin secretion. Thus, it is concluded that the late afternoon and evening bright light exposure could accelerate the dressing behavior in the evening cold.
- 1 July 2001
- Published by Taylor & Francis in Biological Rhythm Research
- Vol. 32 (3) , 333-340
Temporal Variability of Preferred Illuminance Self-Selected by Women during Wakefulness
The primary purpose of this study was to test our hypothesis that the behavior of self-selecting the preferred ambient illuminance might be determined by a load error between the core temperature and its set-point. Seven female volunteers were asked to choose the preferred ambient light intensity by adjusting a rheostat from the time when they rose spontaneously in the morning to the time when they felt sleepy and retired. Rectal temperature was measured every 10 min. Their preferred ambient light intensity increased quickly and then gradually after they rose and rose to approximately 2000 lx over 3 hrs. It decreased gradually and then quickly to the time when they retired. We discussed these findings in terms of a load error between the actual core temperature and its set-point.
- 1 July 2001
- Published by Taylor & Francis in Biological Rhythm Research
- Vol. 32 (3) , 333-340
Temporal Variability of Preferred Illuminance Self-Selected by Women during Wakefulness
The primary purpose of this study was to test our hypothesis that the behavior of self-selecting the preferred ambient illuminance might be determined by a load error between the core temperature and its set-point. Seven female volunteers were asked to choose the preferred ambient light intensity by adjusting a rheostat from the time when they rose spontaneously in the morning to the time when they felt sleepy and retired. Rectal temperature was measured every 10 min. Their preferred ambient light intensity increased quickly and then gradually after they rose and rose to approximately 2000 lx over 3 hrs. It decreased gradually and then quickly to the time when they retired. We discussed these findings in terms of a load error between the actual core temperature and its set-point.
- 1 March 2000
- Published by Wiley in Nursing & Health Sciences
- Vol. 2 (1) , 41-49
The influence of bright light during the daytime upon circadian rhythm of core temperature and its implications for nocturnal sleep
The purpose of the present study was to investigate how bright light during the daytime could influence circadian rhythms of core temperature and nocturnal sleep. Seven females (age 20 ± 2 years) served as participants. The participants lived in the experimental unit for 4 days and were exposed to either 6000 lx (bright) or 200 lx (dim) light during the daytime. Rectal temperature (Tre) was measured during the experimental period. Subjective alertness was measured by the Kansei‐gakuin Sleeping Scale five times a day. The minimum Tre was significantly lower after bright exposure (P < 0.05). The Tre fell rapidly after bright exposure before they retired (P < 0.05) and increased more rapidly during bright light after they woke up (P < 0.05). The morning wakefulness under bright exposure was more active than under dim exposure (P < 0.05). The melatonin secretion at wake up during bright exposure was significantly lower than during dim exposure (P < 0.05). Exposure to bright light during daytime lowered the nocturnal level of Tre, its evening fall was faster and the morning rise quicker. This suggests that indoor light during daytime should be bright enough to promote healthy sleep at night.
- 1 March 2000
- Published by Wiley in Nursing & Health Sciences
- Vol. 2 (1) , 41-49
The influence of bright light during the daytime upon circadian rhythm of core temperature and its implications for nocturnal sleep
The purpose of the present study was to investigate how bright light during the daytime could influence circadian rhythms of core temperature and nocturnal sleep. Seven females (age 20 ± 2 years) served as participants. The participants lived in the experimental unit for 4 days and were exposed to either 6000 lx (bright) or 200 lx (dim) light during the daytime. Rectal temperature (Tre) was measured during the experimental period. Subjective alertness was measured by the Kansei‐gakuin Sleeping Scale five times a day. The minimum Tre was significantly lower after bright exposure (P < 0.05). The Tre fell rapidly after bright exposure before they retired (P < 0.05) and increased more rapidly during bright light after they woke up (P < 0.05). The morning wakefulness under bright exposure was more active than under dim exposure (P < 0.05). The melatonin secretion at wake up during bright exposure was significantly lower than during dim exposure (P < 0.05). Exposure to bright light during daytime lowered the nocturnal level of Tre, its evening fall was faster and the morning rise quicker. This suggests that indoor light during daytime should be bright enough to promote healthy sleep at night.
- 1 July 1999
- Published by Taylor & Francis in Biological Rhythm Research
- Vol. 30 (3) , 332-338
The Influence of the Bright Light Exposure during Daytime on Melatonin Excreting Rate in Urine
The present study was conducted to know the effects of different light intensities exposed during daytime for several hours on melatonin excreting rate in urine and tympanic temperature. Eleven healthy female subjects were exposed to bright light of 6000 lx (Bright) or dim light of 100 lx (Dim) during daytime from 09:00 h to 13:30 h, and then the light condition was kept at 100 lx until the end of test at 14:30 h. The urinary samples were collected from 10:00 h to 14:30 h every 1.5 hours, and melatonin excreting rate in urine was measured by enzyme immunoassay. Melatonin excreting rate in urine was significantly higher in Bright than in Dim at 11:30 h and 14:30 h, and not significant but at high level at 13:00 h (p <0.07). Moreover, average tympanic temperatures were significantly lower in Bright than in Dim from 11:43 h to 14:30 h. These results showed that the bright light exposure during daytime could reduce tympanic temperature, which might result from the increase of melatonin level.
- 1 July 1999
- Published by Taylor & Francis in Biological Rhythm Research
- Vol. 30 (3) , 332-338
The Influence of the Bright Light Exposure during Daytime on Melatonin Excreting Rate in Urine
The present study was conducted to know the effects of different light intensities exposed during daytime for several hours on melatonin excreting rate in urine and tympanic temperature. Eleven healthy female subjects were exposed to bright light of 6000 lx (Bright) or dim light of 100 lx (Dim) during daytime from 09:00 h to 13:30 h, and then the light condition was kept at 100 lx until the end of test at 14:30 h. The urinary samples were collected from 10:00 h to 14:30 h every 1.5 hours, and melatonin excreting rate in urine was measured by enzyme immunoassay. Melatonin excreting rate in urine was significantly higher in Bright than in Dim at 11:30 h and 14:30 h, and not significant but at high level at 13:00 h (p <0.07). Moreover, average tympanic temperatures were significantly lower in Bright than in Dim from 11:43 h to 14:30 h. These results showed that the bright light exposure during daytime could reduce tympanic temperature, which might result from the increase of melatonin level.
- 28 February 1998
- Published by Elsevier in Journal of Thermal Biology
- Vol. 23 (1) , 15-21
The effect of room temperature on rectal temperature during night sleep
- 28 February 1998
- Published by Elsevier in Journal of Thermal Biology
- Vol. 23 (1) , 15-21
The effect of room temperature on rectal temperature during night sleep
- 8 January 1998
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 4 (3) , 347-362
A Comparison of Skin Temperatures and Clothing Microclimate During Moderate Intermittent Exercise in the Cold Between One and Two Layers of Cotton and Polypropylene Underwear
The purpose of this study was to compare the effects of 2 kinds of underwear made from hydrophobic and hydrophilic fabrics on the mean skin temperatures and clothing microclimate (temperature, humidity) in participants performing intermittent exercise in cold environmental conditions. One or 2 layers of cotton underwear (C1, C2) with a 2-piece long-sleeved shirt and long-legged trousers, and 1 or 2 layers of polypropylene underwear (P1, P2) with a 2-piece long-sleeved shirt and long-legged trousers were used as experimental underwear. In addition, the participants wore a 2-piece ski suit as 100% polyester clothing including 100% polyester padding. Ten young adult females volunteered as participants. The experiments were performed in a climatic chamber at an ambient temperature (Ta) of 0°C and an air velocity of 0.26 m s−1. The major findings are summarized as follows: (a) Although the clothing microclimate humidity was not different within the ski suit of outer clothing between C1 and P1, it was significantly higher in P2 than in C2; (b) Clothing microclimate temperature inside the ski suit did not differ between C1 and P1, whereas it was significantly higher in P2 than in C2; (c) The thermal gradient between innermost and outermost of clothing microclimate at back level did not show any difference between C1 and P1, but it was significantly higher in C2 than in P2. These results are discussed in terms of thermal physiology and clothing sciences.
- 8 January 1998
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 4 (3) , 347-362
A Comparison of Skin Temperatures and Clothing Microclimate During Moderate Intermittent Exercise in the Cold Between One and Two Layers of Cotton and Polypropylene Underwear
The purpose of this study was to compare the effects of 2 kinds of underwear made from hydrophobic and hydrophilic fabrics on the mean skin temperatures and clothing microclimate (temperature, humidity) in participants performing intermittent exercise in cold environmental conditions. One or 2 layers of cotton underwear (C1, C2) with a 2-piece long-sleeved shirt and long-legged trousers, and 1 or 2 layers of polypropylene underwear (P1, P2) with a 2-piece long-sleeved shirt and long-legged trousers were used as experimental underwear. In addition, the participants wore a 2-piece ski suit as 100% polyester clothing including 100% polyester padding. Ten young adult females volunteered as participants. The experiments were performed in a climatic chamber at an ambient temperature (Ta) of 0°C and an air velocity of 0.26 m s−1. The major findings are summarized as follows: (a) Although the clothing microclimate humidity was not different within the ski suit of outer clothing between C1 and P1, it was significantly higher in P2 than in C2; (b) Clothing microclimate temperature inside the ski suit did not differ between C1 and P1, whereas it was significantly higher in P2 than in C2; (c) The thermal gradient between innermost and outermost of clothing microclimate at back level did not show any difference between C1 and P1, but it was significantly higher in C2 than in P2. These results are discussed in terms of thermal physiology and clothing sciences.
- 1 January 1996
- Published by Japan Society of Physiological Anthropology in Applied Human Science
- Vol. 15 (1) , 33-39
Effects of Two Kinds of Underwear on Thermophysiological Responses and Clothing Microclimate during 30 Min Walking and 60 Min Recovery in the Cold.
Thermophysiological responses and clothing microclimate under the influences of different underwear materials were compared during walking and recovery in the cold. Two kinds of underwear were used: two layers of cotton underwear with two-piece long-sleeved shirt and long-legged trousers (C), two layers of polypropylene underwear with two-piece long-sleeved shirt and long-legged trousers (P). In addition, the subject put on a two-piece ski suit of 100% polyester including 100% polyester padding. Seven adult females served as subjects in this study. The test was done in a climatic chamber at an ambient air temperature of 2 degrees C, a relative humidity of 65% and an air velocity of 0.14 m.s-1. The subject walked on a motor-driven treadmill with a 6 km/h speed for 30 min followed by 60 min recovery. Rectal temperature, skin temperatures, clothing microclimate (temperature, humidity), metabolic heat production and heart rate were measured. Furthermore, subjective ratings on thermal sensation, sweating/shivering sensation, clothing wettedness sensation and skin wettedness sensation for whole body were asked. The major findings are summarized as follows: 1) Mean skin temperature was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 2) The absolute humidity of innermost layer and outermost layer were not significantly different during walking, but it was significantly higher in P than in C during the recovery. 3) Clothing microclimate temperature of innermost was not significantly different during the first half of walking, but it was significantly higher in C than in P during the second half of walking and significantly lower in C than in P during the recovery. Clothing microclimate temperature of outermost was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 4) Metabolic heat production for the last 10 min during recovery tended to be higher in P. 5) The degree of skin wettedness sensation and clothing wettedness sensation for whole body was significantly higher in P during walking and recovery. Thus, it was concluded that two kinds of underwear with different properties to moisture could influence, not only clothing microclimate, but also physiological parameters like skin temperatures and metabolic heat production in the cold differently.
- 1 January 1996
- Published by Japan Society of Physiological Anthropology in Applied Human Science
- Vol. 15 (1) , 33-39
Effects of Two Kinds of Underwear on Thermophysiological Responses and Clothing Microclimate during 30 Min Walking and 60 Min Recovery in the Cold.
Thermophysiological responses and clothing microclimate under the influences of different underwear materials were compared during walking and recovery in the cold. Two kinds of underwear were used: two layers of cotton underwear with two-piece long-sleeved shirt and long-legged trousers (C), two layers of polypropylene underwear with two-piece long-sleeved shirt and long-legged trousers (P). In addition, the subject put on a two-piece ski suit of 100% polyester including 100% polyester padding. Seven adult females served as subjects in this study. The test was done in a climatic chamber at an ambient air temperature of 2 degrees C, a relative humidity of 65% and an air velocity of 0.14 m.s-1. The subject walked on a motor-driven treadmill with a 6 km/h speed for 30 min followed by 60 min recovery. Rectal temperature, skin temperatures, clothing microclimate (temperature, humidity), metabolic heat production and heart rate were measured. Furthermore, subjective ratings on thermal sensation, sweating/shivering sensation, clothing wettedness sensation and skin wettedness sensation for whole body were asked. The major findings are summarized as follows: 1) Mean skin temperature was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 2) The absolute humidity of innermost layer and outermost layer were not significantly different during walking, but it was significantly higher in P than in C during the recovery. 3) Clothing microclimate temperature of innermost was not significantly different during the first half of walking, but it was significantly higher in C than in P during the second half of walking and significantly lower in C than in P during the recovery. Clothing microclimate temperature of outermost was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 4) Metabolic heat production for the last 10 min during recovery tended to be higher in P. 5) The degree of skin wettedness sensation and clothing wettedness sensation for whole body was significantly higher in P during walking and recovery. Thus, it was concluded that two kinds of underwear with different properties to moisture could influence, not only clothing microclimate, but also physiological parameters like skin temperatures and metabolic heat production in the cold differently.
- 1 January 1995
- Published by Physiological Society of Japan in The Japanese Journal of Physiology
- Vol. 45 (4) , 667-671
Inhibitory Effect of Light of Different Wavelengths on the Fall of Core Temperature during the Nighttime.
Nocturnal core temperature fall was significantly inhibited by green, blue, and red light exposure with 1,000 lx from 21:00 h to 02:00 h. The core temperature in red became identical from that in control during the following sleep period, but not in green and blue. These findings are discussed in terms of urinary melatonin behavior.
- 1 January 1995
- Published by Physiological Society of Japan in The Japanese Journal of Physiology
- Vol. 45 (4) , 667-671
Inhibitory Effect of Light of Different Wavelengths on the Fall of Core Temperature during the Nighttime.
Nocturnal core temperature fall was significantly inhibited by green, blue, and red light exposure with 1,000 lx from 21:00 h to 02:00 h. The core temperature in red became identical from that in control during the following sleep period, but not in green and blue. These findings are discussed in terms of urinary melatonin behavior.