Satoshi Ieiri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Satoshi Ieiri has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
Makoto Hashizume
Department of Advanced Medicine and Innovative Technology, Kyushu University Hospital, Fukuoka, Japan
22 shared publicationsTomoaki Taguchi
Department of Pediatric Surgery, Reproductive and Development Medicine, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
12 shared publicationsMorimasa Tomikawa
11 shared publicationsKazuo Tanoue
Department of Advanced Medicine and Innovative Technology, Kyushu University Hospital, Fukuoka, Japan
8 shared publicationsMunenori Uemura
Department of Advanced Medicine and Innovative Technology, Kyushu University Hospital, Fukuoka, Japan
7 shared publicationsRyota Souzaki
Department of Pediatric Surgery, Reproductive and Development Medicine, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
7 shared publications
Latest Publications
- 12 August 2016
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31  (4) , 1688-1696
A new innovative laparoscopic fundoplication training simulator with a surgical skill validation system
Purpose We developed and validated a specific laparoscopic fundoplication simulator for use with the objective endoscopic surgical skills evaluation system. The aim of this study was to verify the quality of skills of surgeons. Materials and methods We developed a 1-year-old infant body model based on computed tomography data and reproduced pneumoperitoneum model based on the clinical situation. The examinees were divided into three groups: fifteen pediatric surgery experts (PSE), twenty-four pediatric surgery trainees (PSN), and ten general surgeons (GS). They each had to perform three sutures ligatures for construction of Nissen wrap. Evaluate points are time for task, the symmetry of the placement of the sutures, and the uniformity of the interval of suture ligatures in making wrap. And the total path length and velocity of forceps were measured to assess bi-hand coordination. Results PSE were significantly superior to PSN regarding total time spent (p < 0.01) and total path length (p < 0.01). GS used both forceps faster than the other groups, and PSN used the right forceps faster than the left forceps (p < 0.05). PSE were shorter with regard to the total path length than GS (p < 0.01). PSE showed most excellent results in the symmetry of the wrap among three groups. Conclusion Our new model was used useful to validate the characteristics between GS and pediatric surgeon. Both PSE and GS have excellent bi-hand coordination and can manipulate both forceps equally and had superior skills compared to PSN. In addition, PSE performed most compact and accurate skills in the conflicted operative space.
- 12 August 2016
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31  (4) , 1688-1696
A new innovative laparoscopic fundoplication training simulator with a surgical skill validation system
Purpose We developed and validated a specific laparoscopic fundoplication simulator for use with the objective endoscopic surgical skills evaluation system. The aim of this study was to verify the quality of skills of surgeons. Materials and methods We developed a 1-year-old infant body model based on computed tomography data and reproduced pneumoperitoneum model based on the clinical situation. The examinees were divided into three groups: fifteen pediatric surgery experts (PSE), twenty-four pediatric surgery trainees (PSN), and ten general surgeons (GS). They each had to perform three sutures ligatures for construction of Nissen wrap. Evaluate points are time for task, the symmetry of the placement of the sutures, and the uniformity of the interval of suture ligatures in making wrap. And the total path length and velocity of forceps were measured to assess bi-hand coordination. Results PSE were significantly superior to PSN regarding total time spent (p < 0.01) and total path length (p < 0.01). GS used both forceps faster than the other groups, and PSN used the right forceps faster than the left forceps (p < 0.05). PSE were shorter with regard to the total path length than GS (p < 0.01). PSE showed most excellent results in the symmetry of the wrap among three groups. Conclusion Our new model was used useful to validate the characteristics between GS and pediatric surgeon. Both PSE and GS have excellent bi-hand coordination and can manipulate both forceps equally and had superior skills compared to PSN. In addition, PSE performed most compact and accurate skills in the conflicted operative space.
- 1 March 2016
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 26  (3) , 218-221
Feasibility of Single-Incision Laparoscopic Percutaneous Extraperitoneal Closure for Inguinal Hernia by Inexperienced Pediatric Surgeons: Single-Incision Versus Multi-Incision Randomized Trial for 2 Years
Purpose: This study evaluated the stability and risk of single-incision laparoscopic percutaneous extraperitoneal closure (SILPEC) for pediatric inguinal hernia performed by inexperienced pediatric surgeons versus conventional LPEC procedure. Methods: Between 2011 and 2012, a randomized prospective study was performed comparing SILPEC (n = 37, 16 uni- and 21 bilateral patent processus vaginalis [PPV]) to LPEC (n = 72, 39 uni- and 33 bilateral PPV). The procedures were performed in girls with inguinal hernia by inexperienced pediatric surgeons with the assistance of an expert pediatric surgeon. In SILPEC, a laparoscope was placed through a transumbilical incision. A 2-mm trocar for the grasper was inserted through the same incision and introduced into the extraperitoneal cavity. The tip of the trocar was inserted in the abdominal cavity distant from the umbilical incision by the expert surgeon to avoid any complications caused by the in-line view. Using a special needle, the hernial sac was closed extraperitoneally by the inexperienced surgeon. A statistical survey of the mean age at operation, mean operative time, intra- and postoperative complications, and recurrence in the SILPEC and LPEC groups was performed. Results: There were no significant differences in the mean age or operative time. There were fewer total number of postoperative complications in the SILPEC group compared with the LPEC group (P = .0707). No intraoperative complications or recurrence occurred. Conclusions: Considering the risks and need to improve endoscopic surgical skills with useful instruments specialized for SILPEC, inexperienced surgeons can successfully perform SILPEC safely under expert pediatric surgeons.
- 1 March 2016
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 26  (3) , 218-221
Feasibility of Single-Incision Laparoscopic Percutaneous Extraperitoneal Closure for Inguinal Hernia by Inexperienced Pediatric Surgeons: Single-Incision Versus Multi-Incision Randomized Trial for 2 Years
Purpose: This study evaluated the stability and risk of single-incision laparoscopic percutaneous extraperitoneal closure (SILPEC) for pediatric inguinal hernia performed by inexperienced pediatric surgeons versus conventional LPEC procedure. Methods: Between 2011 and 2012, a randomized prospective study was performed comparing SILPEC (n = 37, 16 uni- and 21 bilateral patent processus vaginalis [PPV]) to LPEC (n = 72, 39 uni- and 33 bilateral PPV). The procedures were performed in girls with inguinal hernia by inexperienced pediatric surgeons with the assistance of an expert pediatric surgeon. In SILPEC, a laparoscope was placed through a transumbilical incision. A 2-mm trocar for the grasper was inserted through the same incision and introduced into the extraperitoneal cavity. The tip of the trocar was inserted in the abdominal cavity distant from the umbilical incision by the expert surgeon to avoid any complications caused by the in-line view. Using a special needle, the hernial sac was closed extraperitoneally by the inexperienced surgeon. A statistical survey of the mean age at operation, mean operative time, intra- and postoperative complications, and recurrence in the SILPEC and LPEC groups was performed. Results: There were no significant differences in the mean age or operative time. There were fewer total number of postoperative complications in the SILPEC group compared with the LPEC group (P = .0707). No intraoperative complications or recurrence occurred. Conclusions: Considering the risks and need to improve endoscopic surgical skills with useful instruments specialized for SILPEC, inexperienced surgeons can successfully perform SILPEC safely under expert pediatric surgeons.
- 1 February 2016
- Published by SAGE Publications in Videoscopy™
- Vol. 26  (1)
Laparoscopic Intragastric Surgery for Gastric Tumor to Preserve Cardia Function Under Augmented Reality Navigation System: The First Application for Child Case
Introduction: Laparoscopic intragastric surgery was demonstrated to remove the lesion of posterior wall of stomach.1 We performed this procedure for the pediatric rare disease not only to ensure the minimally invasiveness and good cosmetic appearance but also to preserve the cardia function of stomach. In the video, we present our intragastric resection for gastric tumor under augmented reality navigation system. Materials and Methods: A 12-year-old boy was admitted due to hematemesis. Gastrointestinal (GI) fiberscope revealed the 4 cm size submucosal tumor located at the posterior wall. Located position was near the EC junction. The tumor was cystic type and seemed to be benign lesion. Hence, we planned to perform the intragastric surgery to preserve the cardia function of stomach. We also set up this procedure under augmented reality navigation system to prevent the around organ injury.2 Initially, GI fiberscope was introduced orally to determine the tumor. Next, laparoscope was introduced through the umbilical incision using the open Hasson's method and pneumoperitoneum was established. And then, we used the Funada-kit II (Create Medic Co., Kanagawa, Japan) device with two parallel needles to puncture the stomach and assist suturing the anterior gastric wall to the anterior abdominal wall. In this procedure, all three trocars are placed in the gastric lumen, penetrating both the abdominal and stomach walls to perform a laparoscopic removal of gastric lesions under the observation of GI fiberscope. The operation is then carried out in the gastric lumen with currently available laparoscopic instruments and laparoscopic monitoring.3 Laparoscopic intragastric surgery requires a pneumostomach, which is created by CO2 insufflations through the GI fiberscope.4 Volume images were reconstructed by three-dimensional (3D) viewer application. We used an optical tracking system for registration between volume image and body surface markers. The augmented reality visualization was superimposed preoperative 3D computed tomography (CT) images onto captured laparoscopic live images. Preoperative 3D CT was performed under condition of maximum swallowing air. This is because of the mimicking the situation of pneumostomach during intragastric surgery. Retroperitoneal organs, such as splenic artery and vein, spleen, and pancreas, did not show much deformation and deviation from the data of our previous clinical experiments.2 The operator recognized the hidden vascular variation of the splenic artery and vein, spleen, and pancreas by overlaying an image onto a laparoscopic live image. The tumor was resected by ultrasonically activated device using intragastric surgery. Esophagocardial (EC) junction was kept without injury. Defect of gastric wall was closed under laparoscopic view. Results: There were no intra- and postoperative complications. Pathological diagnosis revealed that the tumor was bronchogenic cyst. The patient had good clinical course after operation. Conclusion: Laparoscopic intragastric surgery is feasible and safe and effective for the pediatric patients. This approach is useful for the tumor lesion of posterior wall and near EC junction to preserve the organ function and to prevent the injury of EC junction. No relevant articles were found in the literature search, and this is the first report referring to the application of intragastric surgery for child case. No competing financial interests exist. Runtime of video: 3 mins 52 secs
- 1 February 2016
- Published by SAGE Publications in Videoscopy™
- Vol. 26  (1)
Laparoscopic Intragastric Surgery for Gastric Tumor to Preserve Cardia Function Under Augmented Reality Navigation System: The First Application for Child Case
Introduction: Laparoscopic intragastric surgery was demonstrated to remove the lesion of posterior wall of stomach.1 We performed this procedure for the pediatric rare disease not only to ensure the minimally invasiveness and good cosmetic appearance but also to preserve the cardia function of stomach. In the video, we present our intragastric resection for gastric tumor under augmented reality navigation system. Materials and Methods: A 12-year-old boy was admitted due to hematemesis. Gastrointestinal (GI) fiberscope revealed the 4 cm size submucosal tumor located at the posterior wall. Located position was near the EC junction. The tumor was cystic type and seemed to be benign lesion. Hence, we planned to perform the intragastric surgery to preserve the cardia function of stomach. We also set up this procedure under augmented reality navigation system to prevent the around organ injury.2 Initially, GI fiberscope was introduced orally to determine the tumor. Next, laparoscope was introduced through the umbilical incision using the open Hasson's method and pneumoperitoneum was established. And then, we used the Funada-kit II (Create Medic Co., Kanagawa, Japan) device with two parallel needles to puncture the stomach and assist suturing the anterior gastric wall to the anterior abdominal wall. In this procedure, all three trocars are placed in the gastric lumen, penetrating both the abdominal and stomach walls to perform a laparoscopic removal of gastric lesions under the observation of GI fiberscope. The operation is then carried out in the gastric lumen with currently available laparoscopic instruments and laparoscopic monitoring.3 Laparoscopic intragastric surgery requires a pneumostomach, which is created by CO2 insufflations through the GI fiberscope.4 Volume images were reconstructed by three-dimensional (3D) viewer application. We used an optical tracking system for registration between volume image and body surface markers. The augmented reality visualization was superimposed preoperative 3D computed tomography (CT) images onto captured laparoscopic live images. Preoperative 3D CT was performed under condition of maximum swallowing air. This is because of the mimicking the situation of pneumostomach during intragastric surgery. Retroperitoneal organs, such as splenic artery and vein, spleen, and pancreas, did not show much deformation and deviation from the data of our previous clinical experiments.2 The operator recognized the hidden vascular variation of the splenic artery and vein, spleen, and pancreas by overlaying an image onto a laparoscopic live image. The tumor was resected by ultrasonically activated device using intragastric surgery. Esophagocardial (EC) junction was kept without injury. Defect of gastric wall was closed under laparoscopic view. Results: There were no intra- and postoperative complications. Pathological diagnosis revealed that the tumor was bronchogenic cyst. The patient had good clinical course after operation. Conclusion: Laparoscopic intragastric surgery is feasible and safe and effective for the pediatric patients. This approach is useful for the tumor lesion of posterior wall and near EC junction to preserve the organ function and to prevent the injury of EC junction. No relevant articles were found in the literature search, and this is the first report referring to the application of intragastric surgery for child case. No competing financial interests exist. Runtime of video: 3 mins 52 secs
- 26 August 2015
- Published by Springer Nature in Pediatric Surgery International
- Vol. 31  (10) , 971-976
The effect of forceps manipulation for expert pediatric surgeons using an endoscopic pseudo-viewpoint alternating system: the phenomenon of economical slow and fast performance in endoscopic surgery
Endoscopic surgery is performed under a horizontal view in comparison to the vertical view that is associated with open surgery. We developed an endoscopic pseudo-viewpoint alternation system with out any scope action. We investigate the effect of this novel system on forceps manipulation among expert pediatric surgeons. Six expert pediatric surgeons performed a Nissen wrap in a fundoplication simulator either with or without this system. The constructed Nissen wrap was evaluated. The total path length and the average velocity of the forceps were also analyzed. The times required either with or without this system were 587.5 ± 122.7 and 634.0 ± 212.4 s (p = 0.45), respectively. The total path lengths of right and left forceps either with or without this system were 12,309 ± 2495.5 and 15,726 ± 5649.6 mm (p = 0.07), 10,091 ± 2439.2 and 12,575 ± 5511.1 mm (p = 0.11), respectively. The average velocity of the right and left forceps with or without this system were 26.9 ± 5.29 and 31.6 ± 1.62 mm/s (p = 0.04), 21.6 ± 2.48 and 25.5 ± 6.48 mm/s (p = 0.15), respectively. There was no significance in the suture balance and suture interval. The endoscopic pseudo-viewpoint alternation system thus made it possible for expert pediatric surgeons to carry out slow and economical forceps manipulation. These effects make it possible for surgeons to perform safe and precise surgery, thus leading to a shortening of operation time.
- 26 August 2015
- Published by Springer Nature in Pediatric Surgery International
- Vol. 31  (10) , 971-976
The effect of forceps manipulation for expert pediatric surgeons using an endoscopic pseudo-viewpoint alternating system: the phenomenon of economical slow and fast performance in endoscopic surgery
Endoscopic surgery is performed under a horizontal view in comparison to the vertical view that is associated with open surgery. We developed an endoscopic pseudo-viewpoint alternation system with out any scope action. We investigate the effect of this novel system on forceps manipulation among expert pediatric surgeons. Six expert pediatric surgeons performed a Nissen wrap in a fundoplication simulator either with or without this system. The constructed Nissen wrap was evaluated. The total path length and the average velocity of the forceps were also analyzed. The times required either with or without this system were 587.5 ± 122.7 and 634.0 ± 212.4 s (p = 0.45), respectively. The total path lengths of right and left forceps either with or without this system were 12,309 ± 2495.5 and 15,726 ± 5649.6 mm (p = 0.07), 10,091 ± 2439.2 and 12,575 ± 5511.1 mm (p = 0.11), respectively. The average velocity of the right and left forceps with or without this system were 26.9 ± 5.29 and 31.6 ± 1.62 mm/s (p = 0.04), 21.6 ± 2.48 and 25.5 ± 6.48 mm/s (p = 0.15), respectively. There was no significance in the suture balance and suture interval. The endoscopic pseudo-viewpoint alternation system thus made it possible for expert pediatric surgeons to carry out slow and economical forceps manipulation. These effects make it possible for surgeons to perform safe and precise surgery, thus leading to a shortening of operation time.
- 18 August 2015
- Published by Springer Nature in Pediatric Surgery International
- Vol. 31  (10) , 963-969
Effectiveness of short-term endoscopic surgical skill training for young pediatric surgeons: a validation study using the laparoscopic fundoplication simulator
Pediatric surgeons require highly advanced skills when performing endoscopic surgery; however, their experience is often limited in comparison to general surgeons. The aim of this study was to evaluate the effectiveness of endoscopic surgery training for less-experienced pediatric surgeons and then compare their skills before and after training. Young pediatric surgeons (n = 7) who participated in this study underwent a 2-day endoscopic skill training program, consisting of lectures, box training and live tissue training. The trainees performed the Nissen construction tasks before and after training using our objective evaluation system. A statistical analysis was conducted using the two-tailed paired Student’s t tests. The time for task was 984 ± 220 s before training and 645 ± 92.8 s after training (p < 0.05). The total path length of both forceps was 37855 ± 10586 mm before training and 22582 ± 3045 mm after training (p < 0.05). The average velocity of both forceps was 26.1 ± 3.68 mm/s before training and 22.9 ± 2.47 mm/sec after training (p < 0.1). The right and left balance of suturing was improved after training (p < 0.05). Pediatric surgery trainees improved their surgical skills after receiving short-term training. We demonstrated the effectiveness of our training program, which utilized a new laparoscopic fundoplication simulator.
- 18 August 2015
- Published by Springer Nature in Pediatric Surgery International
- Vol. 31  (10) , 963-969
Effectiveness of short-term endoscopic surgical skill training for young pediatric surgeons: a validation study using the laparoscopic fundoplication simulator
Pediatric surgeons require highly advanced skills when performing endoscopic surgery; however, their experience is often limited in comparison to general surgeons. The aim of this study was to evaluate the effectiveness of endoscopic surgery training for less-experienced pediatric surgeons and then compare their skills before and after training. Young pediatric surgeons (n = 7) who participated in this study underwent a 2-day endoscopic skill training program, consisting of lectures, box training and live tissue training. The trainees performed the Nissen construction tasks before and after training using our objective evaluation system. A statistical analysis was conducted using the two-tailed paired Student’s t tests. The time for task was 984 ± 220 s before training and 645 ± 92.8 s after training (p < 0.05). The total path length of both forceps was 37855 ± 10586 mm before training and 22582 ± 3045 mm after training (p < 0.05). The average velocity of both forceps was 26.1 ± 3.68 mm/s before training and 22.9 ± 2.47 mm/sec after training (p < 0.1). The right and left balance of suturing was improved after training (p < 0.05). Pediatric surgery trainees improved their surgical skills after receiving short-term training. We demonstrated the effectiveness of our training program, which utilized a new laparoscopic fundoplication simulator.
- 1 July 2015
- Vol. 106  (7) , 213-22
Novel Surgical Skill Evaluation with Reference to Two-handed Coordination.
We evaluated the differences in instrument manipulation skills between expert laparoscopic surgeons and novices. Six expert surgeons who had performed more than 500 laparoscopic surgeries and one skilled instructor at Kyushu University Training Center for Minimally Invasive Surgery, and 20 medical students who had experienced no laparoscopic surgery were enrolled. A new skill assessment task was designed using zippers on an unstable, mobile platform in a box trainer. The examinees were asked to close the zippers, while trying to avoid moving the platform. The path lengths of the tips of the instruments and of the platform were measured, and the performance time was also recorded. Surgical skill score was calculated from the correlation between the path lengths of the instruments and that of the platform, in addition to the performance time. The path lengths of the tips of both instruments and of the platform were significantly shorter in the experts than in the novices (all p < 0.05). The performance time was also significantly shorter for experts than novices (p < 0.05). The surgical skill score was significantly higher for experts than novices (p < 0.01). The differences in the instrument manipulation skills between expert laparoscopic surgeons and novices could therefore be evaluated using our surgical skill scoring system.
- 1 July 2015
- Vol. 106  (7) , 213-22
Novel Surgical Skill Evaluation with Reference to Two-handed Coordination.
We evaluated the differences in instrument manipulation skills between expert laparoscopic surgeons and novices. Six expert surgeons who had performed more than 500 laparoscopic surgeries and one skilled instructor at Kyushu University Training Center for Minimally Invasive Surgery, and 20 medical students who had experienced no laparoscopic surgery were enrolled. A new skill assessment task was designed using zippers on an unstable, mobile platform in a box trainer. The examinees were asked to close the zippers, while trying to avoid moving the platform. The path lengths of the tips of the instruments and of the platform were measured, and the performance time was also recorded. Surgical skill score was calculated from the correlation between the path lengths of the instruments and that of the platform, in addition to the performance time. The path lengths of the tips of both instruments and of the platform were significantly shorter in the experts than in the novices (all p < 0.05). The performance time was also significantly shorter for experts than novices (p < 0.05). The surgical skill score was significantly higher for experts than novices (p < 0.01). The differences in the instrument manipulation skills between expert laparoscopic surgeons and novices could therefore be evaluated using our surgical skill scoring system.
- 1 December 2013
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 8  (6) , 635
Board 549- Technology Innovations Abstract A New Objective... : Simulation in Healthcare
Introduction/Background Various training simulators for laparoscopic surgery skills have been developed, such as virtual reality simulators and box trainers. Surgical skills are typically evaluated by measuring the path lengths of the tips of the operative instruments using three-dimensional tracking sensors. Experienced surgeons are generally able to perform tasks with shorter path lengths and time than inexperienced operators.1,2 However, there is no method of assessing laparoscopic surgery skills designed to specifically assess the suture ligature method, which provides a quantitative result based on the clinical condition. The purpose of this study was to develop a new objective assessment system of the suture ligature method of the intestinal anastomosis model for laparoscopic surgery. In this study, we evaluated objective suturing skill using this system. Methods Materials & Methods: Sixteen doctors who had each performed over 100 laparoscopic surgeries (expert group) and 23 medical students who had no experience of laparoscopic surgery (novice group) were enrolled in this study. The novice group practiced a suturing method to successfully perform three suture ligatures before this experiment. The new assessment system consists of a new artificial intestinal model, which has an intestine-like structure, and a pressure measurement device. The artificial intestinal model consists of four layers, including the mucosal layer, submucosal layer, muscle layer, and serosal layer. Suturing skill was evaluated by internal air pressure of the model. The model has a ten mm size wound at the center. The examinees performed a suturing task using the artificial model with a box trainer. We compared the number of stitches, the performance time, and the internal air pressure between both groups, and examined the similarity of the model to the intestine by a questionnaire given to only the expert group because the novice group had no clinical experience. We analyzed the data and evaluated acceptable values for the skill assessment task in this system. Results for the expert and novice groups were compared using the Student’s t-test. A p value <0.05 was defined as statistically significant. Results: Table 1 shows the Results of the comparisons between the expert group and the novice group. The similarity of the model to the intestine was 71.9%. The appropriate values of the number of stitches, the performance time, and the internal air pressure were three stitches, 417 s, and 5.20 [kPa], respectively, because maximum differences were found between the expert group and novice group under the condition of three stiches. Results: Conclusion Our objective system is useful for assessing suturing skill in laparoscopic surgery in a quantitative manner. References 1. Verdaasdonk EGG, Dankelman J, Lange JF, Stassen LPS. Transfer validity of laparoscopic knot-tying training on a VR simulator to a realistic environment: a randomized controlled trial. Surgical endoscopy. 2008;22(7):1636-42. 2. Hofstad EF, Våpenstad C, Chmarra MK, Langø T, Kuhry E, Mårvik R. A study of psychomotor skills in minimally invasive surgery: what differentiates expert and nonexpert performance. Surgical endoscopy. 2013;27(3):854-63. Disclosures None.
- 1 December 2013
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 8  (6) , 635
Board 549- Technology Innovations Abstract A New Objective... : Simulation in Healthcare
Introduction/Background Various training simulators for laparoscopic surgery skills have been developed, such as virtual reality simulators and box trainers. Surgical skills are typically evaluated by measuring the path lengths of the tips of the operative instruments using three-dimensional tracking sensors. Experienced surgeons are generally able to perform tasks with shorter path lengths and time than inexperienced operators.1,2 However, there is no method of assessing laparoscopic surgery skills designed to specifically assess the suture ligature method, which provides a quantitative result based on the clinical condition. The purpose of this study was to develop a new objective assessment system of the suture ligature method of the intestinal anastomosis model for laparoscopic surgery. In this study, we evaluated objective suturing skill using this system. Methods Materials & Methods: Sixteen doctors who had each performed over 100 laparoscopic surgeries (expert group) and 23 medical students who had no experience of laparoscopic surgery (novice group) were enrolled in this study. The novice group practiced a suturing method to successfully perform three suture ligatures before this experiment. The new assessment system consists of a new artificial intestinal model, which has an intestine-like structure, and a pressure measurement device. The artificial intestinal model consists of four layers, including the mucosal layer, submucosal layer, muscle layer, and serosal layer. Suturing skill was evaluated by internal air pressure of the model. The model has a ten mm size wound at the center. The examinees performed a suturing task using the artificial model with a box trainer. We compared the number of stitches, the performance time, and the internal air pressure between both groups, and examined the similarity of the model to the intestine by a questionnaire given to only the expert group because the novice group had no clinical experience. We analyzed the data and evaluated acceptable values for the skill assessment task in this system. Results for the expert and novice groups were compared using the Student’s t-test. A p value <0.05 was defined as statistically significant. Results: Table 1 shows the Results of the comparisons between the expert group and the novice group. The similarity of the model to the intestine was 71.9%. The appropriate values of the number of stitches, the performance time, and the internal air pressure were three stitches, 417 s, and 5.20 [kPa], respectively, because maximum differences were found between the expert group and novice group under the condition of three stiches. Results: Conclusion Our objective system is useful for assessing suturing skill in laparoscopic surgery in a quantitative manner. References 1. Verdaasdonk EGG, Dankelman J, Lange JF, Stassen LPS. Transfer validity of laparoscopic knot-tying training on a VR simulator to a realistic environment: a randomized controlled trial. Surgical endoscopy. 2008;22(7):1636-42. 2. Hofstad EF, Våpenstad C, Chmarra MK, Langø T, Kuhry E, Mårvik R. A study of psychomotor skills in minimally invasive surgery: what differentiates expert and nonexpert performance. Surgical endoscopy. 2013;27(3):854-63. Disclosures None.
- 12 February 2013
- Published by Springer Nature in Pediatric Surgery International
- Vol. 29  (5) , 501-504
Development of an objective endoscopic surgical skill assessment system for pediatric surgeons: suture ligature model of the crura of the diaphragm in infant fundoplication
Background and aim The Japanese Society of Pediatric Endoscopic Surgeons developed an endoscopic surgical skill qualification (ESSQ) system. However, this is a subjective system we developed and validated an objective skill evaluation system for pediatric surgeons. Methods In the ESSQ system, the task operation is laparoscopic fundoplication. Therefore, we set up a suture ligature model of the crura of the diaphragm for infant fundoplication. Examinees were divided into 2 groups, 10 experts and 16 trainees. They had to perform two suture ligatures of the crura using an intracorporeal knot in the box. Evaluation points were time, force on the tissue, suture tension, stitch spacing, equidistance, mean score, and total score. Statistical analysis was performed and p < 0.05 was considered statistically significant. Results Experts showed better score than trainees in the time score (p < 0.0001), the score for force on the tissue (p < 0.0001), the stitch spacing score (p < 0.05), the equidistance score (p < 0.005), the mean score (p < 0.0001), and the total score (p < 0.0005), respectively. Conclusion The results revealed that the expert group possessed gentle and speedy skills compared with that of the novices. Using this validation study, our established model could be used to objectively evaluate the endoscopic surgical skills of pediatric surgeons.
- 12 February 2013
- Published by Springer Nature in Pediatric Surgery International
- Vol. 29  (5) , 501-504
Development of an objective endoscopic surgical skill assessment system for pediatric surgeons: suture ligature model of the crura of the diaphragm in infant fundoplication
Background and aim The Japanese Society of Pediatric Endoscopic Surgeons developed an endoscopic surgical skill qualification (ESSQ) system. However, this is a subjective system we developed and validated an objective skill evaluation system for pediatric surgeons. Methods In the ESSQ system, the task operation is laparoscopic fundoplication. Therefore, we set up a suture ligature model of the crura of the diaphragm for infant fundoplication. Examinees were divided into 2 groups, 10 experts and 16 trainees. They had to perform two suture ligatures of the crura using an intracorporeal knot in the box. Evaluation points were time, force on the tissue, suture tension, stitch spacing, equidistance, mean score, and total score. Statistical analysis was performed and p < 0.05 was considered statistically significant. Results Experts showed better score than trainees in the time score (p < 0.0001), the score for force on the tissue (p < 0.0001), the stitch spacing score (p < 0.05), the equidistance score (p < 0.005), the mean score (p < 0.0001), and the total score (p < 0.0005), respectively. Conclusion The results revealed that the expert group possessed gentle and speedy skills compared with that of the novices. Using this validation study, our established model could be used to objectively evaluate the endoscopic surgical skills of pediatric surgeons.
- 1 January 2013
- Vol. 184, 424-30
Formulation of wire control mechanism for surgical robot to create virtual reality environment aimed at conducting surgery inside the body.
We here report on the process of developing a surgical robot that can conduct operation "going inside the body without spreading the operational region". The endoscopic robot that we are developing now has a flexible cylindrical body with functions of a set of human arms at the tip and also with vision and haptic sense functions. We evaluated necessary technology factor to complete this robot into categories such as, transmission of energy, adaptation to insides of the body.
- 1 January 2013
- Vol. 184, 424-30
Formulation of wire control mechanism for surgical robot to create virtual reality environment aimed at conducting surgery inside the body.
We here report on the process of developing a surgical robot that can conduct operation "going inside the body without spreading the operational region". The endoscopic robot that we are developing now has a flexible cylindrical body with functions of a set of human arms at the tip and also with vision and haptic sense functions. We evaluated necessary technology factor to complete this robot into categories such as, transmission of energy, adaptation to insides of the body.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _2A2-S10_1
2A2-S10 Superimposing the Image of the Hidden Working Area for Forceps Cannula(Surgical Robotics and Mechatronics (1))
Recently, small incision pediatric surgeries have been widely performed due to their minimally invasiveness. However, they make it difficult for surgeons to manipulate surgical tools. Robotic assist is required to reduce the workload for surgeons. Single port endoscopic surgery (SPS) assist robot we have developed is important option for it. It enables surgeons to perform precise operation using its tool manipulators. However, the operative field of a child is so tight that manipulators are limited for range of movement and hide working area from their view. We proposed the compensation method that complements the view by superimposing the image taken with added endoscope on forceps region of view. This paper presents a basic evaluation for validity of proposal method. In the experiment, delay time and resultant error of complemented image satisfied requirement specifications. In addition, we heard views of a pediatric surgeon on it.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _2A2-S10_1
2A2-S10 Superimposing the Image of the Hidden Working Area for Forceps Cannula(Surgical Robotics and Mechatronics (1))
Recently, small incision pediatric surgeries have been widely performed due to their minimally invasiveness. However, they make it difficult for surgeons to manipulate surgical tools. Robotic assist is required to reduce the workload for surgeons. Single port endoscopic surgery (SPS) assist robot we have developed is important option for it. It enables surgeons to perform precise operation using its tool manipulators. However, the operative field of a child is so tight that manipulators are limited for range of movement and hide working area from their view. We proposed the compensation method that complements the view by superimposing the image taken with added endoscope on forceps region of view. This paper presents a basic evaluation for validity of proposal method. In the experiment, delay time and resultant error of complemented image satisfied requirement specifications. In addition, we heard views of a pediatric surgeon on it.