Franz Ziegler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Franz Ziegler has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Basit Khalid
Directorate of Civil Engineering and Design, Islamabad, Pakistan
2 shared publications - Christoph Adam
Universität Innsbruck, Unit of Applied Mechanics, Technikerstr. 13, 6020 Innsbruck, Austria
1 shared publication Markus J. Hochrainer
Geoconsult‐Wien, A‐1150 Vienna, Austria
1 shared publication- Michael Reiterer
REVOTEC
1 shared publication P. A. Fotiu
Fachhochschule Wiener Neustadt, Johannes Gutenbergstrasse 3, A-2700 Wiener Neustadt, Austria AT
1 shared publication- Rudolf Heuer
TU Wien
1 shared publication
Latest Publications
- 22 December 2014
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 14 (1) , 213-214
Passive damping of bridge vibrations by tuned liquid column gas dampers
- 22 December 2014
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 14 (1) , 213-214
Passive damping of bridge vibrations by tuned liquid column gas dampers
- 27 June 2012
- Published by Springer Nature in Archive of Applied Mechanics
- Vol. 82 (10-11) , 1423-1437
A novel aseismic foundation system for multipurpose asymmetric buildings
- 27 June 2012
- Published by Springer Nature in Archive of Applied Mechanics
- Vol. 82 (10-11) , 1423-1437
A novel aseismic foundation system for multipurpose asymmetric buildings
- 9 March 2012
- Published by Springer Nature in Acta Mechanica
- Vol. 223 (8) , 1567-1581
Reliable dynamic analysis of an uncertain compound bridge under traffic loads
- 9 March 2012
- Published by Springer Nature in Acta Mechanica
- Vol. 223 (8) , 1567-1581
Reliable dynamic analysis of an uncertain compound bridge under traffic loads
- 1 January 2011
- Published by Springer Nature
- p. 29-42
Vibrations of layered structures with fuzzy core stiffness/fuzzy interlayer slip
- 1 January 2011
- Published by Springer Nature
- p. 29-42
Vibrations of layered structures with fuzzy core stiffness/fuzzy interlayer slip
- 1 January 2010
- Published by Springer Nature
- p. 215-222
The basis of optimal active(static and dynamic) shape- and stress-control by means of smart materials
- 1 January 2010
- Published by Springer Nature
- p. 215-222
The basis of optimal active(static and dynamic) shape- and stress-control by means of smart materials
- 9 August 2008
- Published by Springer Nature in Acta Mechanica
- Vol. 201 (1-4) , 249-267
Special design of tuned liquid column-gas dampers for the control of spatial structural vibrations
- 9 August 2008
- Published by Springer Nature in Acta Mechanica
- Vol. 201 (1-4) , 249-267
Special design of tuned liquid column-gas dampers for the control of spatial structural vibrations
- Open Access
- 1 December 2006
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 6 (1) , 345-346
A vertically acting tuned liquid column damper
- 1 December 2006
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 6 (1) , 345-346
Open AccessA vertically acting tuned liquid column damper
- 1 November 2006
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 13 (6) , 980-1002
Control of tall building vibrations by sealed tuned liquid column dampers
Sealed liquid column damper (TLCD) are tuned in the low‐frequency range of application (say below 5 Hz) with respect to a selected natural frequency of the main structure by means of a geometrical transformation in analogy to the classical tuned mass damper (TMD). To improve the performance in MDOF buildings even further, the influence of neighboring modes is taken into account by fine‐tuning in state space, rendering the optimal parameters modified. Final adjustments are easily made in the course of in situ testing. The passive sealed TLCD making use of the gas‐spring effect and, since turbulent damping of assigned strength is present, is perfectly suited to counteract steady‐state vibrations. Reduction of transient vibration peaks, observed within the initial period of the strong motion phase of earthquakes, requires active control, realized by controlled pressure input into the gas volume. The TLCD is commonly sufficiently damped and the vertical component of the seismic excitation does not cause parametric resonance. A sufficient condition based on the cut‐off damping must be checked. Computer simulations and small scale experimental testing under time‐harmonic‐, single seismogram‐ and random‐ forcing confirmed the excellent performance and robustness of the TLCD. Optimal solutions for benchmark MDOF structures with multiple TLCD are presented when excited either by wind gusts or by earthquakes. A base‐isolated structure is considered with the effective damping supplied by a TLCD in the basement. Copyright © 2005 John Wiley & Sons, Ltd.
- 1 November 2006
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 13 (6) , 980-1002
Control of tall building vibrations by sealed tuned liquid column dampers
Sealed liquid column damper (TLCD) are tuned in the low‐frequency range of application (say below 5 Hz) with respect to a selected natural frequency of the main structure by means of a geometrical transformation in analogy to the classical tuned mass damper (TMD). To improve the performance in MDOF buildings even further, the influence of neighboring modes is taken into account by fine‐tuning in state space, rendering the optimal parameters modified. Final adjustments are easily made in the course of in situ testing. The passive sealed TLCD making use of the gas‐spring effect and, since turbulent damping of assigned strength is present, is perfectly suited to counteract steady‐state vibrations. Reduction of transient vibration peaks, observed within the initial period of the strong motion phase of earthquakes, requires active control, realized by controlled pressure input into the gas volume. The TLCD is commonly sufficiently damped and the vertical component of the seismic excitation does not cause parametric resonance. A sufficient condition based on the cut‐off damping must be checked. Computer simulations and small scale experimental testing under time‐harmonic‐, single seismogram‐ and random‐ forcing confirmed the excellent performance and robustness of the TLCD. Optimal solutions for benchmark MDOF structures with multiple TLCD are presented when excited either by wind gusts or by earthquakes. A base‐isolated structure is considered with the effective damping supplied by a TLCD in the basement. Copyright © 2005 John Wiley & Sons, Ltd.