Glenn Harvel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Glenn Harvel has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
J. S. Chang
Department of Engineering Physics , McMaster University , Hamilton, Ontario, Canada ; McMaster Institute of Applied Radiation Science , McMaster University , Hamilton, Ontario, Canada
3 shared publicationsA. Lebert
Fac. of Eng., McMaster Univ., Hamilton, Ont., Canada
1 shared publication- Amjad Farah
Mem. ASME Faculty of Energy Systems and Nuclear Science, University of Ontario Institute of Technology, 2000 Simcoe Street North, Oshawa, ON L1J 5S1, Canada
1 shared publication D. Brocilo
Fac. of Eng., McMaster Univ., Hamilton, Ont., Canada
1 shared publicationD. Ewing
Fac. of Eng., McMaster Univ., Hamilton, Ont., Canada
1 shared publication- David Mann
Faculty of Energy Systems and Nuclear Science, University of Ontario Institute of Technology, 2000 Simcoe Street North, Oshawa, ON L1H 7K4, Canada
1 shared publication
Latest Publications
- Open Access
- 16 July 2021
- Published by ASME International
Synergy of an SMR for Addressing Remote Communities Non-Nuclear Waste
SMRs are a popular topic with a significant number of designs with a wide range of sizes. There has been some assessment done with respect to non-electrical applications including district heating and desalination. Other concerns have dealt with nuclear waste minimization through actinide burning. The drive of this type of work is to find alternative uses for the SMRs so that
- 16 July 2021
- Published by ASME International
Open AccessSynergy of an SMR for Addressing Remote Communities Non-Nuclear Waste
SMRs are a popular topic with a significant number of designs with a wide range of sizes. There has been some assessment done with respect to non-electrical applications including district heating and desalination. Other concerns have dealt with nuclear waste minimization through actinide burning. The drive of this type of work is to find alternative uses for the SMRs so that
- 17 June 2016
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 2 (3) , 031016
Analysis of Computational Fluid Dynamics Code FLUENT Capabilities for Supercritical Water Heat-Transfer Applications in Vertical Bare Tubes
In this paper, the computational fluid dynamics (CFD) code FLUENT was used to predict wall-temperature profiles inside vertical bare tubes with supercritical water (SCW) as the cooling medium, to assess the capabilities of FLUENT for SCW heat-transfer applications. Numerical results are compared to experimental data and current one-dimensional (1D) models represented by existing heat-transfer empirical correlations. Wall-temperature and heat-transfer coefficients were analyzed to select the best model to describe the fluid flow before, at, and after the pseudocritical region. and turbulent models were evaluated in the process, with variations in the submodel parameters such as viscous heating, thermal effects, and low-Reynolds-number correction. Results of the analysis show a fit of for wall temperatures using the SST model within the deteriorated heat-transfer regime and less than within the normal heat-transfer regime. The accuracy of the model is higher than any empirical correlation tested in the mentioned regimes and provides additional information about the multidimensional effects between the bulk-fluid and wall temperatures.- 17 June 2016
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 2 (3) , 031016
Analysis of Computational Fluid Dynamics Code FLUENT Capabilities for Supercritical Water Heat-Transfer Applications in Vertical Bare Tubes
In this paper, the computational fluid dynamics (CFD) code FLUENT was used to predict wall-temperature profiles inside vertical bare tubes with supercritical water (SCW) as the cooling medium, to assess the capabilities of FLUENT for SCW heat-transfer applications. Numerical results are compared to experimental data and current one-dimensional (1D) models represented by existing heat-transfer empirical correlations. Wall-temperature and heat-transfer coefficients were analyzed to select the best model to describe the fluid flow before, at, and after the pseudocritical region. and turbulent models were evaluated in the process, with variations in the submodel parameters such as viscous heating, thermal effects, and low-Reynolds-number correction. Results of the analysis show a fit of for wall temperatures using the SST model within the deteriorated heat-transfer regime and less than within the normal heat-transfer regime. The accuracy of the model is higher than any empirical correlation tested in the mentioned regimes and provides additional information about the multidimensional effects between the bulk-fluid and wall temperatures.- 1 January 2015
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 1 (1) , 011008
Study on Specifics of Forced-Convective Heat Transfer in Supercritical Carbon Dioxide
The appropriate description of heat transfer to coolants at the supercritical state is limited by the current understanding. Thus, this poses one of the main challenges in the development of supercritical-fluids applications for Generation-IV reactors. Since the thermodynamic critical point of water is much higher than that of carbon dioxide (), it is more affordable to run heat-transfer experiments in supercritical . The data for supercritical can be later scaled and used for supercritical water-based reactor designs. The objective of this paper is, therefore, to discuss the basis for comparison of relatively recent experimental data on supercritical obtained at the facilities of the Korea Atomic Energy Research Institute (KAERI) and Chalk River Laboratories (CRL) of the Atomic Energy of Canada Limited (AECL). Based on the available instrumental error, a thorough analysis of experimental errors in wall- and bulk-fluid temperatures and heat transfer coefficient was conducted. A revised heat-transfer correlation for the CRL data is presented. A dimensional criterion for the onset of the deteriorated heat transfer in the form of a linear relation between heat flux and mass flux is proposed. A preliminary heat-transfer correlation for the joint CRL and KAERI datasets is presented.- 1 January 2015
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 1 (1) , 011008
Study on Specifics of Forced-Convective Heat Transfer in Supercritical Carbon Dioxide
The appropriate description of heat transfer to coolants at the supercritical state is limited by the current understanding. Thus, this poses one of the main challenges in the development of supercritical-fluids applications for Generation-IV reactors. Since the thermodynamic critical point of water is much higher than that of carbon dioxide (), it is more affordable to run heat-transfer experiments in supercritical . The data for supercritical can be later scaled and used for supercritical water-based reactor designs. The objective of this paper is, therefore, to discuss the basis for comparison of relatively recent experimental data on supercritical obtained at the facilities of the Korea Atomic Energy Research Institute (KAERI) and Chalk River Laboratories (CRL) of the Atomic Energy of Canada Limited (AECL). Based on the available instrumental error, a thorough analysis of experimental errors in wall- and bulk-fluid temperatures and heat transfer coefficient was conducted. A revised heat-transfer correlation for the CRL data is presented. A dimensional criterion for the onset of the deteriorated heat transfer in the form of a linear relation between heat flux and mass flux is proposed. A preliminary heat-transfer correlation for the joint CRL and KAERI datasets is presented.- 20 October 2009
- Published by Taylor & Francis in Research in Nondestructive Evaluation
- Vol. 20 (4) , 215-229
Nondestructive Evaluation of Multiply Connected Electrical Arc Furnace Graphite Rod Electrodes
The low quality of graphite electrodes in a small electrical arc furnace causes many problems on furnace operation. High temperature and erosion at the remote electrode tip, and defects in the electrode increase the probability of electrode failure due to ageing phenomena such as thermal stress cracking. Most measurement techniques cannot determine the electrode quality under such conditions as the high temperature is highly destructive to the device. Nondestructive sensing techniques such as ultrasonics can possibly be used. Experimental studies on the feasibility of using mechanically connected and chemically bonded graphite rod electrodes as a sensing medium for an ultrasonic signal are performed. Graphite rod porosity and defects are inspected using ultrasonic, infrared, and Real-Time Neutron Radiography nondestructive inspection techniques. The acoustic characteristics of the graphite rods are determined, and the soundwave velocity of the graphite rods is measured to be 2529.4 m/s. Ultrasonic frequencies from 60.0 kHz to 10.0 MHz are studied. The optimum ultrasonic frequency for propagation through graphite rods, hence quality inspection, are 500.0 kHz and 1.0 MHz. The effect of electrode length and the number of mechanical joints on the operating ultrasonic frequency are discussed in detail.
- 20 October 2009
- Published by Taylor & Francis in Research in Nondestructive Evaluation
- Vol. 20 (4) , 215-229
Nondestructive Evaluation of Multiply Connected Electrical Arc Furnace Graphite Rod Electrodes
The low quality of graphite electrodes in a small electrical arc furnace causes many problems on furnace operation. High temperature and erosion at the remote electrode tip, and defects in the electrode increase the probability of electrode failure due to ageing phenomena such as thermal stress cracking. Most measurement techniques cannot determine the electrode quality under such conditions as the high temperature is highly destructive to the device. Nondestructive sensing techniques such as ultrasonics can possibly be used. Experimental studies on the feasibility of using mechanically connected and chemically bonded graphite rod electrodes as a sensing medium for an ultrasonic signal are performed. Graphite rod porosity and defects are inspected using ultrasonic, infrared, and Real-Time Neutron Radiography nondestructive inspection techniques. The acoustic characteristics of the graphite rods are determined, and the soundwave velocity of the graphite rods is measured to be 2529.4 m/s. Ultrasonic frequencies from 60.0 kHz to 10.0 MHz are studied. The optimum ultrasonic frequency for propagation through graphite rods, hence quality inspection, are 500.0 kHz and 1.0 MHz. The effect of electrode length and the number of mechanical joints on the operating ultrasonic frequency are discussed in detail.
- 1 January 2009
- Published by Springer Nature
- p. 57-61
Dust Flow Separator Type Electrostatic Precipitator for a Particulate Matter Emission Control from Natural Gas Combution
- 1 January 2009
- Published by Springer Nature
- p. 57-61
Dust Flow Separator Type Electrostatic Precipitator for a Particulate Matter Emission Control from Natural Gas Combution
- 1 January 2007
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Nuclear Engineering (ICONE)
- Vol. 2007.15, _ICONE1510
ICONE15-10676 FINNED FUEL ELEMENT TWO-PHASE FLOW PARAMETER MEASUREMENTS USING REAL-TIME NEUTRON RADIOGRAPHY
The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void distribution becomes more symmetrical. The spacer however does generate an axial void fraction maximum at the upstream of the spacer with a small depletion zone at the exit of the spacer. By analysis of the instantaneous local void distribution, void fluctuation at the heated wall due to boiling was clearly observed. Also, the agglomeration and breakup of the cold-wall void was evident. The dynamic effects of the local void transients will be discussed in detail.
- 1 January 2007
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Nuclear Engineering (ICONE)
- Vol. 2007.15, _ICONE1510
ICONE15-10676 FINNED FUEL ELEMENT TWO-PHASE FLOW PARAMETER MEASUREMENTS USING REAL-TIME NEUTRON RADIOGRAPHY
The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void distribution becomes more symmetrical. The spacer however does generate an axial void fraction maximum at the upstream of the spacer with a small depletion zone at the exit of the spacer. By analysis of the instantaneous local void distribution, void fluctuation at the heated wall due to boiling was clearly observed. Also, the agglomeration and breakup of the cold-wall void was evident. The dynamic effects of the local void transients will be discussed in detail.
- 10 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Observation of electrohydrodynamically atomized dielectric liquids by realtime and high speed infra-red thermal images
Electrohydrodynamic (EHD) atomization or EHD spraying has been used in many industrial applications and more recently for spraying heated dielectric fluids. In this work, an experimental investigation has been conducted using high speed infrared thermal imaging techniques to measure transient temperature distributions of droplets and liquid columns in EHD spraying. The system used is capable of measuring 100 /spl mu/m particles with transient of 0.1 ms. The experiment was initially conducted in a small drop tower using single heated black ink droplet particles of known size to establish limitations of measuring technique. The technique was then applied to EHD atomization of mineral oil and decane. The results show that the present technique is capable of measuring the dynamics of liquid droplets with a spatial resolution of 200 /spl mu/m and temperature profiles with 0.1 K accuracy. The effect of applied voltage and liquid flow rates on the maximum surface droplet temperature are discussed in details.
- 10 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Observation of electrohydrodynamically atomized dielectric liquids by realtime and high speed infra-red thermal images
Electrohydrodynamic (EHD) atomization or EHD spraying has been used in many industrial applications and more recently for spraying heated dielectric fluids. In this work, an experimental investigation has been conducted using high speed infrared thermal imaging techniques to measure transient temperature distributions of droplets and liquid columns in EHD spraying. The system used is capable of measuring 100 /spl mu/m particles with transient of 0.1 ms. The experiment was initially conducted in a small drop tower using single heated black ink droplet particles of known size to establish limitations of measuring technique. The technique was then applied to EHD atomization of mineral oil and decane. The results show that the present technique is capable of measuring the dynamics of liquid droplets with a spatial resolution of 200 /spl mu/m and temperature profiles with 0.1 K accuracy. The effect of applied voltage and liquid flow rates on the maximum surface droplet temperature are discussed in details.
- 1 January 2004
- Published by ASME International
- p. 485-489
An Advanced Ultrasonic Technique for Flow and Void Fraction Measurements of Two-Phase Flow
In this paper, we present a hybrid type contrapropagating transmission ultrasonic technique (CPTU) for flow and time averaging ultrasonic transmission intensity void fraction measurements (TATIU) of air-water two-phase flow, which is tested in the new two-phase flow test section mounted recently onto an existing single phase flow rig at the Nuclear Engineering Institute (IEN)/CNEN, Brazil. The circular pipe test section is made of 51.2 mm stainless steel, followed by a transparent extruded acrylic pipe aimed at flow visualization. The two-phase flow rig operates in several flow regimes: bubbly, smooth stratified, wavy stratified and slug flow. The observed flow patterns are compared with the Mandhane et al.’s experimental and Lightstone et al.’s numerical flow regime map for horizontal two phase flows. These flow patterns will be identified by time averaging transmission intensity ultrasonic techniques which have been developed to meet this particular application. A contrapropagating transmission ultrasonic flowmeter is used to measure the flow rate of liquid phase. A pulse-echo TATIU ultrasonic technique used to measure the void fraction of the horizontal test section assembling at IEN is presented. Other flow parameters can be deduced by processing the signals obtained by the CPTU ultrasonic flowmeter and the pulse-echo generator-receiver (TATIU system).
- 1 January 2004
- Published by ASME International
- p. 485-489
An Advanced Ultrasonic Technique for Flow and Void Fraction Measurements of Two-Phase Flow
In this paper, we present a hybrid type contrapropagating transmission ultrasonic technique (CPTU) for flow and time averaging ultrasonic transmission intensity void fraction measurements (TATIU) of air-water two-phase flow, which is tested in the new two-phase flow test section mounted recently onto an existing single phase flow rig at the Nuclear Engineering Institute (IEN)/CNEN, Brazil. The circular pipe test section is made of 51.2 mm stainless steel, followed by a transparent extruded acrylic pipe aimed at flow visualization. The two-phase flow rig operates in several flow regimes: bubbly, smooth stratified, wavy stratified and slug flow. The observed flow patterns are compared with the Mandhane et al.’s experimental and Lightstone et al.’s numerical flow regime map for horizontal two phase flows. These flow patterns will be identified by time averaging transmission intensity ultrasonic techniques which have been developed to meet this particular application. A contrapropagating transmission ultrasonic flowmeter is used to measure the flow rate of liquid phase. A pulse-echo TATIU ultrasonic technique used to measure the void fraction of the horizontal test section assembling at IEN is presented. Other flow parameters can be deduced by processing the signals obtained by the CPTU ultrasonic flowmeter and the pulse-echo generator-receiver (TATIU system).