NBNatali Bauer

Natali Bauer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Natali Bauer has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 17 October 2012
      • Vol. 40  (5) , 309-17

    [Bacterial susceptibility testings of the lower airways of diseased dogs].

    by A Steinfeld, E Prenger-Berninghoff, N Bauer, R Weiß, A Moritz

    In this retrospective study over 5 years the bacterial flora of the deep airways of diseased dogs was sampled using bronchioalveolar lavage and its in-vitro susceptibility to numerous antimicrobial agents was analysed. Susceptibility testing of bacterial isolates from 84 dogs performed from 2004 to 2009 were evaluated and compared to data collected in 1999/2000. The 99 bacterial isolates comprised Pasteurella spp. (27.3%), Bordetella bronchiseptica (20.2%), Staphylococcus spp. (18.2%), Escherichia coli (15.2%), Klebsiella spp. (8.1%), Pseudomonas spp. (7.0%), and Streptococcus spp. (4.0%). Lavage samples of eight dogs revealed simultaneous occurrence of more than one species. The majority of the tested Bordetella bronchiseptica-isolates were susceptible to fluoroquinolones as well as tetracycline, doxycycline and polymyxin B. The number of amoxicillin/clavulanic acid- and chloramphenicol-resistant isolates decreased compared to 1999/2000. The increase of chloramphenicol-susceptible isolates was statistically significant. The tested Staphylococcus-isolates revealed a susceptibility to fluoroquinolones, amoxicillin, cephalexin, doxycycline, and polymyxin B. Compared to the earlier study, a major portion exhibited susceptibility to chloramphenicol and tetracycline. None of the Klebsiella spp. tested in 1999/2000 was resistant to enrofloxacin, whereas only 62.5% of the isolates examined during 2004-2009 were susceptible. A susceptibility of all tested Klebsiella -isolates was detectable with respect to polymyxin B. Regarding E.coli , none of the tested antibiotics revealed an in-vitro activity against all of the tested isolates. The increase of amoxicillin/clavulanic acid-resistant isolates was statistically significant. The study demonstrates the benefits of bronchioalveolar lavage as a diagnostic tool to ensure a responsible utilisation of antibiotics. Most of the tested bacterial isolates were susceptible to fluoroquinolones.


  • Bakterienisolate aus dem unteren Respirationstrakt von erkrankten Hunden und deren aktuelle Resistenzsituation

    by E. Prenger-Berninghoff, N. Bauer, R. Weiß, A. Moritz, A. Steinfeld

    Gegenstand: Retrospektive Untersuchung der mittels bronchoalveolärer Lavage (BAL) gewonnenen Keimflora der tiefen Atemwege erkrankter Hunde auf ihre Antibiotikaempfindlichkeit über 5 Jahre. Material und Methoden: Auswertung der Ergebnisse der Agardiffusionstests von Bakterienisolaten, die in den Jahren 2004–2009 von 84 Hunden isoliert wurden, und Vergleich mit den Resultaten einer gleichartigen Analyse der Jahre 1999/2000. Ergebnisse: Bei den 99 geprüften Bakterienisolaten handelte es sich um Pasteurella spp. (27,3%), Bordetella bronchiseptica (20,2%), Staphylococcus spp. (18,2%), Escherichia coli (15,2%), Klebsiella spp. (8,1%), Pseudomonas spp. (7,0%) und Streptococcus spp. (4,0%). Bei acht Hunden lagen Mischkulturen vor. Die Mehrzahl der Bordetella-(B.-)bronchiseptica-Isolate erwies sich als sensibel gegenüber den Fluorchinolonen sowie Tetracyclin, Doxycyclin und Polymyxin B. Im Vergleich zu 1999/2000 zeigte sich ein höherer Anteil der gegenüber Amoxicillin/Clavulansäure und Chloramphenicol empfindlichen B.-bronchiseptica-Isolate, wobei die Zunahme bezüglich Chloramphenicol statistisch signifikant war. Die überwiegende Anzahl der Staphylococcus-Isolate erwies sich gegenüber Enrofloxacin, Marbofloxacin, Amoxicillin/Clavulansäure, Chloramphenicol, Cephalexin, Doxycyclin und Polymyxin B sensibel. Im Vergleich zu 1999/2000 ergab sich ein erhöhter Anteil an Chloramphenicolund Tetracyclin-sensiblen Staphylococcus-Isolaten. Der Anteil Enrofloxacin-sensibler KlebsiellenIsolate betrug 62,5%, während er 1999/2000 bei 100% lag. Eine Sensibilität aller getesteten Klebsiellen-Isolate ließ sich noch gegenüber Polymyxin B nachweisen. Kein Antibiotikum zeigte eine Wirksamkeit gegenüber allen E.-coli-Isolaten. Statistisch signifikant war die Abnahme der gegenüber Amoxicillin/Clavulansäure-sensiblen Isolate. Schlussfolgerung und klinische Relevanz: Die Studie unterstreicht den Nutzen der BAL für eine ätiologische Diagnostik und den anschließenden fundierten Einsatz von Antibiotika. Die Mehrzahl der Bakterienisolate erwies sich als empfindlich gegenüber den Fluorchinolonen. Objective: In this retrospective study over 5 years the bacterial flora of the deep airways of diseased dogs was sampled using bronchioalveolar lavage and its in-vitro susceptibility to numerous antimicrobial agents was analysed. Material and methods: Susceptibility testing of bacterial isolates from 84 dogs performed from 2004 to 2009 were evaluated and compared to data collected in 1999/2000. Results: The 99 bacterial isolates comprised Pasteurella spp. (27.3%), Bordetella bronchiseptica (20.2%), Staphylococcus spp. (18.2%), Escherichia coli (15.2%), Klebsiella spp. (8.1%), Pseudomonas spp. (7.0%), and Streptococcus spp. (4.0%). Lavage samples of eight dogs revealed simultaneous occurrence of more than one species. The majority of the tested Bordetella bronchiseptica-isolates were susceptible to fluoroquinolones as well as tetracycline, doxycycline and polymyxin B. The number of amoxicillin/clavulanic acidand chloramphenicol-resistant isolates decreased compared to 1999/2000. The increase of chloramphenicol-susceptible isolates was statistically significant. The tested Staphylococcus-isolates revealed a susceptibility to fluoroquinolones, amoxicillin, cephalexin, doxycycline, and polymyxin B. Compared to the earlier study, a major portion exhibited susceptibility to chloramphenicol and tetracycline. None of the Klebsiella spp. tested in 1999/2000 was resistant to enrofloxacin, whereas only 62.5% of the isolates examined during 2004–2009 were susceptible. A susceptibility of all tested Klebsiella-isolates was detectable with respect to polymyxin B. Regarding E. coli, none of the tested antibiotics revealed an in-vitro activity against all of the tested isolates. The increase of amoxicillin/clavulanic acid-resistant isolates was statistically significant. Conclusion and clinical relevance: The study demonstrates the benefits of bronchioalveolar lavage as a diagnostic tool to ensure a responsible utilisation of antibiotics. Most of the tested bacterial isolates were susceptible to fluoroquinolones.


  • Influence of catheter intervention on platelet function and activation in a pig model for endovascular embolization of arteriovenous malformations

    by Constanze Leuser, Sibylle Schlottmann, Ralf Siekmann, Martin Heidt, Andreas Moritz, Natali Bauer

  • Use of the platelet function analyser PFA-100™ in juvenile pigs

    by Constanze Leuser, Sibylle Schlottmann, Ralf Siekmann, Martin Heidt, Andreas Moritz, Natali Bauer


    • 8 June 2010
      • Vol. 38  (3) , 139-46

    Myeloperoxidase deficiency in dogs observed with the ADVIA®120. A retrospective study.

    by S Klenner, J Richartz, N Bauer, A Moritz

    In contrast to humans, neutrophil myeloperoxidase deficiency (MPOD) has been rarely investigated in dogs. The hematology analyzer ADVIA®120 differentiates leukocytes based on the cellular volume and their myeloperoxidase concentration. The aim of this study was the characterization of myeloperoxidase deficiency in dogs and the evaluation of the diagnostic use of the ADVIA®120 Myeloperoxidase Index (MPXI). ADVIA® peroxidase scatter plots indicative of MPOD were reviewed. Severity of MPOD was classified semiquantitatively in three groups (MPOD grade1-3): MPOD grade1 (MPOD-1): neutrophils showing an abnormal shift of the population, <25% extending in the monocyte cluster and therefore misclassified, MPOD-2: ~25-50% of neutrophils misclassified, MPOD-3: 50-100% of the neutrophils misclassified due to their location in the monocyte cluster. Sex, age, and breed of the dogs as well as diagnosis, and MPXI were recorded. 29 dogs (nine females and 20 males belonging to 23 breeds) with 38 analyses consistent with MPOD were found. Diseases were characterized by severe leukocyte consumption and included mainly parvovirosis (8/29), DIC/sepsis (3/29), pyometra, pyothorax, pneumonia, pancreatic abscess, and cystitis. A significantly lower mean MPXI in MPOD-3 was present in comparison to the mean MPXI of MPOD-1 (p<0.05), however, there was a great overlap between the groups. Diseases associated with neutrophil consumption may show an acquired MPOD in dogs. High standard deviation limits the diagnostic use of the MPXI for detection of MPOD. The ADVIA®120 cytograms are a good screening tool for detection of MPOD in dogs, but the use of the MPXI is impaired in this species.


  • Biodegradable β‐Tri‐Calciumphosphate/hydroxyethyl methacrylate enhanced three component bone adhesive demonstrates biocompatibility without evidence of systemic toxicity in a rabbit model

    by Natali B. Bauer, Nina Brinke, Christian Heiss, Agnes B. Skorupa, Fabian Peters, Ralf Kraus, Reinhard Schnettler, Andreas Moritz

    Bone gluing is an attractive surgical technique; however, its use in patients is hampered by a variety of side effects. Therefore, it was the aim of this ethically approved study to evaluate a novel biodegradable β-Tri-Calciumphosphate (β-TCP, Cerasorb®)-enhanced bone adhesive regarding its toxicity and biocompatibility in a rabbit model. Fifty healthy New Zealand White rabbits were assigned in the study (n = 21) and sham-operated control group (n = 29). In the study group, a cylindrical part (4.6 × 10.0 mm) of the proximal tibia and distal femur was removed, reimplanted, and bone adhesive was applied. Blinded physical examination and sampling for hematology, clinical chemistry, and acute phase proteins (haptoglobin, C-reactive protein (CRP)) was performed before surgery and after 12, 24, 48, 72, 240, and 504 h. Significant findings of the physical examination included a slightly higher grading of warmth (p = 0.0019) and pain (p < 0.0001) of the wound 240 h after surgery in the study group. No significant differences between albumin, haptoglobin, CRP, and urea concentrations in both groups were evident, whereas the study group demonstrated significantly lower leukocyte count, total protein, and globulin concentrations (p < 0.0001). As expected, both groups showed a marked transient increase in muscle enzymes (Creatine Kinase and Aspartate Aminotransferase) following the surgery (p < 0.0001). Twelve to 24 h after surgery, a significant decrease in ionized calcium from 1.38 ± 0.12 mmol/L to 1.06 ± 0.13 mmol/L was noted in the study group (p < 0.0001). The results clearly indicated that the novel β-TCP-enhanced bone adhesive showed good biocompatibility without significant evidence of acute or subacute local or systemic toxicity. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009


  • Evaluation of the Cardiac reader® as a point-of-care instrument for measurement of fibrin D-dimers in dogs

    by A. Moritz, N. Bauer

    Objective: The aim of this study was the evaluationof the automated point-of-care analyzer Cardiac reader® for quantitative fibrin D-dimer measurement compared to the Liatest™ D-Di™ run on the bench top analyzer STA Compact (all Roche). Material and methods: 41 fresh canine blood specimens submitted from the Clinic for Small Animals, Justus-Liebig-University Giessen were included. Measurement of fibrin D-dimers with the Liatest™ D-Di™ immunoturbidimetric assay was performed in citrated blood plasma stored at –80 °C until analysis. Using the Cardiac reader, D-dimer plasma concentrations were measured with an immunological assay in heparinized fresh (< 1 hour) whole blood specimens. Results: Mean intra-assay coefficient of variation (CV) was 6.13% (range: 2.2–10.0%) for the Liatest™ D-Di and 19.8% (range: 20.1–19.6%) for the Cardiac reader. Fibrin D-dimers detected with the STA Compact exceeded the upper limit of the reference interval (0.4 μg/ml; n = 62 healthy dogs) in 20/41 samples. There was a fair correlation between D-dimer measurements with the Cardiac reader and the comparison method (r = 0.78). Generally, results were underestimated with a mean proportional bias (0.45 μg/ml). The area under the Receiver Operating Characteristic (ROC) curve was 0.895 regarding the detection of increased fibrin D-dimers with the Cardiac reader. At a cut-off value of > 0.2 μg/ml, sensitivity/specificity were 85%/91% and positive/negative likelihood ratios were 8.93/0.17. At a lower cut-off value of 0.15 μg/ml sensitivity and specificity were 90% and 66%, respectively. Conclusion and clinical relevance: The Cardiac reader can be used for quantitative measurement of canine D-dimers, however, due to the odds of false negative results and the high imprecision the comparison method should be preferred. Ziel dieser Studie war die Evaluation des automatischen Notfallanalyse-Geräts Cardiac reader® für die quantitative Messung von FibrinD-Dimeren mit dem immunologischen Test Cardiac D-Dimer™. Als Vergleichsmethode diente der mit dem Großgerät STA Compact durchgeführte immunoturbidimetrische Liatest D-Di™ (alle Roche Diagnostics GmbH). Material und Methoden: Untersucht wurden 41 frische kanine Zitratblutproben. Sie stammten von Hunden mit Verdacht auf Verbrauchskoagulopathie, hämorrhagischer Diathese, Thrombosen, Leberinsuffizienz, Hyperkalzämie, Neoplasien sowie von zwei gesunden Hunden. Als Material für den Liatest D-Di™ diente Zitratplasma, das bis zur Analyse bei –80 °C gelagert wurde. Die Messung mit dem Cardiac reader erfolgte mit heparinsierten frischen (< 1 Stunde alten) Vollblutproben. Ergebnisse: Der mittlere Intra-assay-Variationskoeffizient (VK) betrug 6,13% (Range 2,2–10,0%) für den Liatest D-Di und 19,8% (Range 20,05–19,56%) für den Cardiac reader. Bei 20/41 Proben fanden sich D-Dimer-Konzentrationen, die den für den Liatest D-Di ermittelten oberen Referenzbereich von 0,4 μg/ml (n = 62 gesunde Hunde) überschritten. Die lineare Regressionsanalyse der logarithmierten Daten ergab eine mäßige Korrelation zwischen beiden Methoden (r = 0,78), allerdings wurden die Ergebnisse mit einer mittleren proportionalen Mittelwertabweichung (Bias) von 0,45 μg/ml unterschätzt. Die Fläche unter der Receiver-Operating-Characteristic-(ROC-)Kurve betrug 0,895 hinsichtlich der Erkennung erhöhter Fibrin-D-Dimer-Werte mit dem Cardiac reader (Optimum 1,00). Bei einem Cut-off-Wert von > 0,2 μg/ml betrugen Sensitivität/Spezifität 85%/91% und das positive/negative Wahrscheinlichkeitsverhältnis (likelihood ratio) 8,93 und 0,17. Bei einem niedrigeren Cut-off-Wert von 0,15 μg/ml lagen Sensitivität und Spezifität bei 90% bzw. 66%. Schlussfolgerung und klinische Relevanz: Der Cardiac reader® kann als Notfallanalysegerät für die quantitative Bestimmung kaniner D-Dimere verwendet werden. Berücksichtigt werden müssen jedoch die Möglichkeit falsch negativer Resultate und die im Vergleich zu einem Großgerät hohe Impräzision, sodass der Vergleichsmethode der Vorzug gegeben werden sollte.


  • Evaluation of three Methods for Measurement of Hemoglobin and Calculated Hemoglobin Variables with the ADVIA 120® and ADVIA 2120® Systems in Goats

    by Natali Bauer, Andreas Moritz

    The present study investigated 3 methods of hemoglobin (Hb) determination in goats using the ADVIA 120 and ADVIA 2120 systems. Ethylenediaminetetraacetic acid anticoagulated caprine blood samples (n = 40 goats) were subjected to Hb determination via the cyanmethemoglobin methods in both instruments and a novel, cyanide-free, colorimetric method with the ADVIA 2120. Statistical analysis of the data included a linear regression, Passing-Bablok regression, and Bland-Altman diagram. Colorimetric Hb results determined with both analyzers had excellent correlation (r = 0.98); however, a mean proportional bias of −19.1% was present in comparison to the reference method. There also was excellent agreement between cellular Hb concentrations when measured with both analyzers (r = 0.96), and the constant bias was close to zero. However, imprecision was higher compared to colorimetric methods. Excellent to fair agreement was evident for all calculated erythrocyte and Hb variables. Because of the excellent correlation between the ADVIA 120 and ADVIA 2120, the cyanide-free method of Hb determination could be used with caprine blood specimens; however, the proportional bias must be considered.


  • Evaluation of three methods for measurement of hemoglobin and calculated hemoglobin parameters with the ADVIA 2120 and ADVIA 120 in dogs, cats, and horses

    by Natali Bauer, Andreas Moritz

    Background: Besides flow cytometric detection of cellular hemoglobin (HGB) concentration, the ADVIA 2120 uses a novel cyanide‐free colorimetric method to determine extracellular total HGB concentration. In human samples, the results are equivalent to those of the cyanmethemoglobin method on the ADVIA 120. Cyanide‐free HGB measurement has not been evaluated in animal samples.Objectives: The aim of this prospective study was to compare the 3 methods of HGB analysis on the ADVIA 2120 and ADVIA 120 in blood samples from dogs, cats, and horses.Methods: Consecutive fresh K3EDTA blood samples from 119 dogs, 113 cats, and 151 horses submitted to the Central Laboratory, Department of Veterinary Clinical Sciences, Justus‐Liebig University Giessen, were included. A CBC was performed on each sample using the ADVIA 2120 and ADVIA 120. Colorimetric and cellular HGB concentrations and all calculated variables based on HGB measurement were compared using linear regression, Passing Bablok regression, and Bland Altman plots, using the ADVIA 120 as the reference methodResults: In samples from all species, an excellent correlation was found for colorimetric HGB results (r=0.99). HGB measured with the cyanide‐free method was overestimated on the ADVIA 2120 compared with the cyanide‐based method on the ADVIA 120, with a mean proportional bias of −21.0% (dog), −22.0% (cat), and −19.4% (horse). The correlation of cellular HGB concentration between analyzers was excellent (r=0.99); however, imprecision was higher than for colorimetric methods. Excellent to fair agreement was found for all calculated variables.Conclusion: The cyanide‐free method of HGB determination is appropriate for use in blood samples from animals, provided the proportional bias is considered.