KMKazunori Miyata

Kazunori Miyata

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kazunori Miyata has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Prospective Comparison of One-Piece and Three-Piece Tecnis Aspheric Intraocular Lenses: 1-year Stability and its Effect on Visual Function

    by Kazunori Miyata, Yasushi Kataoka, Jiro Matsunaga, Masato Honbo, Keiichiro Minami

    Purpose: To compare the stability and visual function of one-piece hydrophobic intraocular lens (IOL) (ZCB00, Abbot Medical Optics) and a three-piece hydrophobic IOL (ZA9003, Abbot Medical Optics) after cataract surgery. Materials and methods: Eighteen eyes of 18 patients with the one-piece IOL and 20 eyes of 20 patients with the three-piece IOL who underwent cataract surgery were evaluated prospectively on best corrected distance visual acuity, postoperative refractive error, IOL decentration and tilt, anterior chamber depth (ACD), spherical aberration and contrast sensitivity. Measurements were performed 1 week and 1, 3, 6 and 12 months postoperatively. The postoperative outcomes were compared between the two groups. Results: In the one-piece group, a hyperopic refractive error (p < 0.002) and deeper ACDs during 1-year post-operatively were observed compared with the three-piece group. There were no significant differences in BCVA, IOL tilt, spherical aberration or contrast sensitivity. Conclusions: The stability of the one-piece IOL was greater than that of the three-piece IOL. The postoperative ACD and refractive error demonstrated that an anteriorly offset haptic in the one-piece IOL allowed incremental fixation to the posterior capsule.


    • 1 August 2014
      • Vol. 118  (8) , 645-51

    [The anti-inflammatory effect of 0.1% bromfenac and 0.1% betamethasone combination in post-cataract surgery patients with diabetes mellitus].

    by Yukiko Terada, Ayami Masuda, Ryohei Nejima, Yoko Maruyama, Kazunori Miyata

    To compare the post cataract surgery anti-inflammatory effect of bromfenac monotherapy and of bromfenac and betamethasone combination therapy in diabetes mellitus patients. A prospective study approved by the Institutional Review Board. Fifty-one eyes of 51 patients were randomly allocated to either bromfenac 0.1% monotherapy (n = 23) or combined therapy with bromfenac 0.1% and betamethasone 0.1% (n = 28). After surgery, monotherapy group was administered bromfenac alone for 8 weeks, while the combined therapy group was administered both bromfenac and betamethasone for 2 weeks, bromfenac alone for the next 6 weeks. The amount of change from preoperative values in anterior chamber flare and foveal thickness were compared between the 2 groups. There was no significant difference in change in anterior chamber flare between the 2 groups. The increase in foveal thickness 4 weeks postoperatively was significantly larger in the bromfenac group (p = 0.0356). Four patients of the bromfenac group, all with a history of diabetic macular edema, developed macular edema after surgery. Bromfenac and betamethasone combination exhibited a stronger anti-inflammatory effect after cataract surgery patients with diabetes mellitus. In particular, patients with a history of diabetic macular edema were susceptible to foveal thickening and macular edema, and a combined treatment is desirable.


    • 1 September 2013
      • Vol. 117  (9) , 743-8

    [Pterygium excision using bulbar conjunctival autograft with intraoperative mitomycin C for primary pterygium: a retrospective assessment of 1832 eyes].

    by Ayami Masuda, Koki Takahashi, Ryohei Nejima, Keiichiro Minami, Kazunori Miyata

    To retrospectively assess the efficacy of pterygium excision using bulbar conjunctival autograft with intraoperative mitomycin C (MMC) for primary pterygium. Primary pterygium eyes of 1482 patients (1832 eyes) which had undergone excision surgery using bulbar conjunctival autograft with intraoperative MMC in Miyata Eye Hospital were studied. The patients' background and position and the size of the pterygium were reviewed. For 1188 eyes that were followed up 1 year or longer, the recurrence rate and periods were assessed. Factors such as age, occupation, sex, the size of pterygium and the skill of the surgeon were examined as risk factors for recurrence. Mean age was 65.0 +/- 10.0 years. The pterygium was in the nasal side in 99.0% of eyes, and the size in 55.4% of eyes was equal to the distance between one and two thirds of the radius of the cornea. The recurrence rate was 3.96% and was noted 9 months after the surgery. Significant risk factors were age of patient (p = 0.028) and the skill of the surgeon (p = 0.022). Pterygium excision using bulbar conjunctival autograft with intraoperative mitomycin C was effective in primary pterygium.


    • 1 January 2013
      • Vol. 117  (1) , 35-43

    [Long-term outcomes of Boston keratoprosthesis].

    by Yosai Mori, Ryohei Nejima, Keiichiro Minami, Kazunori Miyata, Kazutaka Kamiya, Masahiko Fukud

    To evaluate the clinical efficacy and safety of am implanted Boston keratoprosthesis Type I (Boston KPro). Six eyes of 6 patients who had experienced repeated graft failure underwent Boston KPro implantation and were followed up for over one year. The mean age of the patients was 62.7 years. There were 3 eyes with glaucoma and 1 eye with fungal keratitis preoperatively. Best-corrected visual acuity (BCVA), complications, and postoperative treatment were evaluated. Mean follow-up duration was 33.9 months. Preoperative BCVA of hand motion to 0.02 improved to counting fingers at 30 cm to 1.0 at 1 month postoperatively. At the last follow-up, it remained stable at counting fingers at 10 cm to 1.2. There were no intraoperative complications. Postoperative complications included 4 eyes with retroprosthetic membrane formation, one eye with elevated intraocular pressure, bacterial conjunctivitis, recurrent fungal keratitis, posterior capsular opacification, cystoids macular edema, vitreous opacity and epiretinal membranes that were all treated. No keratoprosthesis extrusion, donor cornea necrosis or progressive loss of visual field was observed. With continuous and appropriate postoperative management, use of the Boston KPro can produce long-term positive outcomes.


    • 1 April 2012
      • Vol. 116  (4) , 367-73

    [Effects of laser in situ keratomileusis on intraocular pressure measurements in Japanese myopic eyes].

    by Shinichiro Ohtani, Junya Ashizawa, Tomokazu Samejima, Kazunori Miyata, Makoto Aihara, Keiichiro Minami

    To prospectively compare preoperative and postoperative measurements of intraocular pressure (IOP) using Goldmann applanation tonometry (GAT), noncontact tonometer (NCT), and Dynamic contour tonometer (DCT) in eyes undergoing myopic laser in situ keratomileusis (LASIK) and to examine the effects of preoperative corneal curvature and IOP, and the change in central corneal thickness (CCT). One hundred six eyes of 53 patients underwent myopic LASIK with -5.3 +/- 2.3 (mean +/- SD) diopters. Within 4 weeks before and at 1 month after LASIK, IOP using GAT, NCT and DCT and CCT were measured. Postoperatively, although IOP was reduced in the three measurements, IOP changes in DCT (-0.9 +/- 1.7 mmHg) were significantly lower than in the GAT (-3.6 +/- 2.1 mmHg) and in the NCT (-4.7 +/- 1.9 mmHg) measurements (p < 0.001, Tukey test). In all the measurements, the decrease in the IOP increased with the higher preoperative IOP (p < 0.001). Changes in the CCT were significantly correlated in the GAT and NCT measurements (p < 0.015). IOP measurements using DCT minimized the changes in IOP readings after myopic LASIK in Japanese eye. This demonstrated that the DCT was effective for IOP monitoring after LASIK.

  • Effect on visual acuity of increased surface light scattering in intraocular lenses

    by Kazunori Miyata, Masato Honbo, Shinichiro Otani, Ryohei Nejima, Keiichiro Minami

    To assess the long-term increase in surface light scattering of foldable hydrophobic acrylic intraocular lenses (IOLs) and to evaluate its effect on visual acuity. Miyata Eye Hospital, Miyazaki, Japan. Cross-sectional study. The clinical records of patients who received an Acrysof IOL (study group) or a Sensar AR40 or AR40e IOL (control group) were reviewed retrospectively. Surface light scattering of IOLs was measured 1 year postoperatively or later. The corrected distance visual acuity (CDVA) at the surface-light-scattering examination was compared with the CDVA 1 month after IOL implantation. The changes in CDVA over time were compared with the increase in surface light scattering. The study evaluated 466 eyes of 337 patients. Surface light scattering in the study group continued to increase up to 15 years postoperatively. The light scattering was higher on the anterior IOL surface after 4.5 years. Increased surface light scattering had no significant impact on CDVA; however, there were more cases with decreased CDVA when the surface light scattering exceeded 50 computer-compatible tape steps. Surface light scattering with the implanted foldable hydrophobic acrylic IOL continuously increased during the postoperative years and was a risk for decreased visual acuity.


  • Open Access

    Influence of cataract surgery on pupil size in patients with diabetes mellitus

    by Kiyohito Totsuka, Satoshi Kato, Takashi Shigeeda, Masato Honbo, Yasushi Kataoka, Masaaki Nakahara, Kazunori Miyata