Osamu Nakamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Osamu Nakamura has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Satoshi Kawata
Department of Applied Physics/Handai Frontier Research Center, Osaka University, Suita, Osaka 565-0871, Japan
3 shared publicationsK. Fujita
Department of Applied Physics, Osaka University, Suita, Osaka 565 Japan
1 shared publicationKatsumasa Fujita
Department of Applied Physics, Osaka University, 2-1 Yamadaoka, Suita, Osaka, Japan
1 shared publicationKazuya Goto
Department of Applied Physics, Osaka University, Suita, Osaka 565-0871, Japan
1 shared publicationMakoto Kobayashi
The authors are with the Department of Applied Physics, Osaka University, Suita, Osaka 565-0871, Japan
1 shared publicationMinoru Kobayashi
Department of Applied Physics, Osaka University, 2-1 Yamadaoka, Suita, Osaka, Japan
1 shared publication
Latest Publications
- 15 October 2002
- Published by Optica Publishing Group in Optics Letters
- Vol. 27 (20) , 1797-1799
Transcutaneous photocoupler for transmission of biological signals
A compact, photocouplerlike system is presented for wireless transcutaneous transmission of biological signals. The system consists of an optically powered near-infrared light transmitter, a receiver for the signals from it, and a near-infrared light source with which to irradiate it. The transmitter, which is implanted under the skin, is transcutaneously coupled with the receiver and the light source, which are combined and placed on the skin. The transmitter, which is powered transcutaneously by the light source, then amplifies a signal input to it and sends intensity-modulated light transcutaneously to the receiver. With this system, electromyograms and neuronal firing patterns of live rats have been successfully recorded.
- 15 October 2002
- Published by Optica Publishing Group in Optics Letters
- Vol. 27 (20) , 1797-1799
Transcutaneous photocoupler for transmission of biological signals
A compact, photocouplerlike system is presented for wireless transcutaneous transmission of biological signals. The system consists of an optically powered near-infrared light transmitter, a receiver for the signals from it, and a near-infrared light source with which to irradiate it. The transmitter, which is implanted under the skin, is transcutaneously coupled with the receiver and the light source, which are combined and placed on the skin. The transmitter, which is powered transcutaneously by the light source, then amplifies a signal input to it and sends intensity-modulated light transcutaneously to the receiver. With this system, electromyograms and neuronal firing patterns of live rats have been successfully recorded.
- 1 August 2002
- Published by Optica Publishing Group in Optics Letters
- Vol. 27 (15) , 1324-1326
Second-harmonic-generation microscope with a microlens array scanner
We propose a multifocus scanning technique in second-harmonic-generation (SHG) microscopy in which the SHG detection efficiency and the image acquisition rate are improved by several tens of times compared with typical single-focus scanning techniques. Because of a microlens array scanner, the laser beam of a mode-locked Ti:sapphire laser is split into beamlets, and the same number of foci are formed in the specimen. Parallel scanning of the foci enables us to observe real-time images of the specimen. The imaging properties and the usefulness of the microscope are demonstrated by SHG images of living HeLa cells and rat cardiac myocytes.- 1 August 2002
- Published by Optica Publishing Group in Optics Letters
- Vol. 27 (15) , 1324-1326
Second-harmonic-generation microscope with a microlens array scanner
We propose a multifocus scanning technique in second-harmonic-generation (SHG) microscopy in which the SHG detection efficiency and the image acquisition rate are improved by several tens of times compared with typical single-focus scanning techniques. Because of a microlens array scanner, the laser beam of a mode-locked Ti:sapphire laser is split into beamlets, and the same number of foci are formed in the specimen. Parallel scanning of the foci enables us to observe real-time images of the specimen. The imaging properties and the usefulness of the microscope are demonstrated by SHG images of living HeLa cells and rat cardiac myocytes.- 20 April 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (12) , 2724-2727
Nondestructive inspection of Phaseolus coccineus L soya beans by use of near-infrared lasers
We propose a nondestructive inspection method for the quantitative analysis of molds inside soya beans (Phaseolus coccineus L.) that does not render the beans unfit for human consumption. Three near-infrared lasers are used for multispectral transmission imaging of the beans. Eigenvalue analysis and a least-squares method are used for estimation of the diffuse reflectance spectrum of each type of mold. The estimated spectra are used for determining the internal concentration of the molds inside the beans. Experimental results verify the usefulness of our method.
- 20 April 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (12) , 2724-2727
Nondestructive inspection of Phaseolus coccineus L soya beans by use of near-infrared lasers
We propose a nondestructive inspection method for the quantitative analysis of molds inside soya beans (Phaseolus coccineus L.) that does not render the beans unfit for human consumption. Three near-infrared lasers are used for multispectral transmission imaging of the beans. Eigenvalue analysis and a least-squares method are used for estimation of the diffuse reflectance spectrum of each type of mold. The estimated spectra are used for determining the internal concentration of the molds inside the beans. Experimental results verify the usefulness of our method.
- 15 September 1996
- Published by Optica Publishing Group in Optics Letters
- Vol. 21 (18) , 1415-1417
4Pi confocal optical system with phase conjugation
We propose a 4Pi confocal system that incorporates a phase-conjugate mirror into the system to solve the alignment problem and automatically correct the spherical aberration associated with the conventional 4Pi confocal system when observing a thick sample. The proposed system is experimentally verified by use of cerium-doped barium titanate crystal as the phase-conjugate mirror. The full width of the central peak is ∼0.15 μm. We also theoretically verify the advantage of automatic correction of the spherical aberration by calculating the intensity distribution at the focal spot.
- 15 September 1996
- Published by Optica Publishing Group in Optics Letters
- Vol. 21 (18) , 1415-1417
4Pi confocal optical system with phase conjugation
We propose a 4Pi confocal system that incorporates a phase-conjugate mirror into the system to solve the alignment problem and automatically correct the spherical aberration associated with the conventional 4Pi confocal system when observing a thick sample. The proposed system is experimentally verified by use of cerium-doped barium titanate crystal as the phase-conjugate mirror. The full width of the central peak is ∼0.15 μm. We also theoretically verify the advantage of automatic correction of the spherical aberration by calculating the intensity distribution at the focal spot.
- 1 April 1988
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 5 (4) , 554-561
Optical microscope tomography II Nonnegative constraint by a gradient-projection method
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 1 April 1988
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 5 (4) , 554-561
Optical microscope tomography II Nonnegative constraint by a gradient-projection method
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.