Conor Heneghan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Conor Heneghan has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Stephen James Redmond
School of Electrical and Electronic Engineering, University College Dublin, Dublin, Ireland
3 shared publications - C. P. Chua
School of Electrical, Electronic and Mechanical Engineering, University College Dublin, Ireland
2 shared publications Chern-Pin Chua
School of Electrical, Electronic and Mechanical Engineering, University College Dublin, Dublin, Ireland
2 shared publications- Deirdre A. Hurley
University College Dublin School of Public Health Physiotherapy and Sports Science, Dublin, Leinster
2 shared publications - Grainne O. Donoghue
UCD School of Public Health, Physiotherapy and Sport Science University College Dublin Dublin Ireland
2 shared publications Patricia Boyle
The Respiratory Sleep Disorders Unit, St. Vincent's University Hospital, Dublin, Ireland
2 shared publications
Latest Publications
- Open Access
- 16 April 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 70
Physiotherapy for sleep disturbance in chronic low back pain: a feasibility randomised controlled trial
Sleep disturbance is becoming increasingly recognised as a clinically important symptom in people with chronic low back pain (CLBP, low back pain >12 weeks), associated with physical inactivity and depression. Current research and international clinical guidelines recommend people with CLBP assume a physically active role in their recovery to prevent chronicity, but the high prevalence of sleep disturbance in this population may be unknowingly limiting their ability to participate in exercise-based rehabilitation programmes and contributing to poor outcomes. There is currently no knowledge concerning the effectiveness of physiotherapy on sleep disturbance in people with chronic low back pain and no evidence of the feasibility of conducting randomized controlled trials that comprehensively evaluate sleep as an outcome measure in this population.
- 16 April 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 70
Open AccessPhysiotherapy for sleep disturbance in chronic low back pain: a feasibility randomised controlled trial
Sleep disturbance is becoming increasingly recognised as a clinically important symptom in people with chronic low back pain (CLBP, low back pain >12 weeks), associated with physical inactivity and depression. Current research and international clinical guidelines recommend people with CLBP assume a physically active role in their recovery to prevent chronicity, but the high prevalence of sleep disturbance in this population may be unknowingly limiting their ability to participate in exercise-based rehabilitation programmes and contributing to poor outcomes. There is currently no knowledge concerning the effectiveness of physiotherapy on sleep disturbance in people with chronic low back pain and no evidence of the feasibility of conducting randomized controlled trials that comprehensively evaluate sleep as an outcome measure in this population.
- 5 January 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (3) , 945-954
Towards Using Photo-Plethysmogram Amplitude to Measure Blood Pressure During Sleep
There is considerable interest in non-intrusive and reliable continuous ambulatory blood pressure measurement systems. Pulse amplitude is the peak to trough amplitude of the photo-plethysmogram signal. We compared pulse amplitude with a currently popular parameter, the pulse arrival time (PAT), for estimating continuous systolic blood pressure (SBP). Overnight sleep data from 18 young, healthy subjects (14 M 4 F, age 24 ± 5 years, BMI 23.8 ± 4.0 kg/m2) was analyzed. We found that pulse amplitude was more effective than PAT for estimating SBP during sleep. Mean coherence between pulse amplitude and SBP was significantly stronger than that for PAT [p < 0.001, 95% CI: 0.21–0.25 (finger), 0.11–0.14 (wrist)]. Correlation between pulse amplitude and SBP was significantly stronger than that for PAT [p < 0.001, 95% CI: 0.46–0.53 (finger), 0.13–0.20 (wrist)]. SBP estimation errors were significantly lower using pulse amplitude [p < 0.001, 95% CI: −1.55 to −1.29 mmHg (finger), −0.53 to −0.36 mmHg (wrist)]. We also found that while pulse amplitude was closely related to SBP, the relationship weakened during and around REM sleep (ANOVA of REM, transitional Wake-REM and transitional REM-Sleep versus other sleep states: F = 24.7, p < 0.001). These results suggest that pulse amplitude is potentially a more suitable measure than pulse arrival time for estimating continuous blood pressure.
- 5 January 2010
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 38 (3) , 945-954
Towards Using Photo-Plethysmogram Amplitude to Measure Blood Pressure During Sleep
There is considerable interest in non-intrusive and reliable continuous ambulatory blood pressure measurement systems. Pulse amplitude is the peak to trough amplitude of the photo-plethysmogram signal. We compared pulse amplitude with a currently popular parameter, the pulse arrival time (PAT), for estimating continuous systolic blood pressure (SBP). Overnight sleep data from 18 young, healthy subjects (14 M 4 F, age 24 ± 5 years, BMI 23.8 ± 4.0 kg/m2) was analyzed. We found that pulse amplitude was more effective than PAT for estimating SBP during sleep. Mean coherence between pulse amplitude and SBP was significantly stronger than that for PAT [p < 0.001, 95% CI: 0.21–0.25 (finger), 0.11–0.14 (wrist)]. Correlation between pulse amplitude and SBP was significantly stronger than that for PAT [p < 0.001, 95% CI: 0.46–0.53 (finger), 0.13–0.20 (wrist)]. SBP estimation errors were significantly lower using pulse amplitude [p < 0.001, 95% CI: −1.55 to −1.29 mmHg (finger), −0.53 to −0.36 mmHg (wrist)]. We also found that while pulse amplitude was closely related to SBP, the relationship weakened during and around REM sleep (ANOVA of REM, transitional Wake-REM and transitional REM-Sleep versus other sleep states: F = 24.7, p < 0.001). These results suggest that pulse amplitude is potentially a more suitable measure than pulse arrival time for estimating continuous blood pressure.
- Open Access
- 2 October 2009
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 10 (1) , 122
Objective and subjective assessment of sleep in chronic low back pain patients compared with healthy age and gender matched controls: a pilot study
While approximately 70% of chronic low back pain (CLBP) sufferers complain of sleep disturbance, current literature is based on self report measures which can be prone to bias and no objective data of sleep quality, based exclusively on CLBP are available. In accordance with the recommendations of The American Sleep Academy, when measuring sleep, both subjective and objective assessments should be considered as the two are only modestly correlated, suggesting that each modality assesses different aspects of an individual's sleep experience. Therefore, the purpose of this study was to expand previous research into sleep disturbance in CLBP by comparing objective and subjective sleep quality in participants with CLBP and healthy age and gender matched controls, to identify correlates of poor sleep and to test logistics and gather information prior to a larger study.
- 2 October 2009
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 10 (1) , 122
Open AccessObjective and subjective assessment of sleep in chronic low back pain patients compared with healthy age and gender matched controls: a pilot study
While approximately 70% of chronic low back pain (CLBP) sufferers complain of sleep disturbance, current literature is based on self report measures which can be prone to bias and no objective data of sleep quality, based exclusively on CLBP are available. In accordance with the recommendations of The American Sleep Academy, when measuring sleep, both subjective and objective assessments should be considered as the two are only modestly correlated, suggesting that each modality assesses different aspects of an individual's sleep experience. Therefore, the purpose of this study was to expand previous research into sleep disturbance in CLBP by comparing objective and subjective sleep quality in participants with CLBP and healthy age and gender matched controls, to identify correlates of poor sleep and to test logistics and gather information prior to a larger study.
- 31 December 2008
- Published by Elsevier in Neurocomputing
- Vol. 72 (1-3) , 112-118
Denoising of magnetoencephalographic data using spatial averaging
- 31 December 2008
- Published by Elsevier in Neurocomputing
- Vol. 72 (1-3) , 112-118
Denoising of magnetoencephalographic data using spatial averaging
- Open Access
- 1 October 2008
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 31 (10) , 1432-1439
A Portable Automated Assessment Tool for Sleep Apnea Using a Combined Holter-Oximeter
Resource limitations have raised interest in portable monitoring systems that can be used by specialist sleep physicians as part of an overall strategy to improve access to the diagnosis of sleep apnea. This study validates a combined electrocardiogram and oximetry recorder (Holter-oximeter) against simultaneous polysomnography for detection of sleep apnea. Prospective study. A dedicated sleep disorders unit. 59 adults presenting for evaluation of suspected sleep apnea. NA. An automated algorithm previously developed for sleep apnea detection was applied to the electrocardiogram and oximetry measurements. The algorithm provides (a) epoch-by-epoch estimates of apnea occurrence and (b) estimates of overall per-subject AHI. Using separate thresholds of AHI ≥15 and AHI 20 and 0.04 respectively, with 16.7% of subjects having intermediate test results (AHI 5–14/h). Regardless of AHI, 85.3% of respiratory events were correctly annotated on an epoch-by-epoch basis. AHI underestimation bias was 0.9/h, and the antilogs of log-transformed limits of agreement were 0.3 and 2.7. Correlation between estimated and reference AHI was 0.95 (P < 0.001). Combined Holter-oximeter monitoring compares well with polysomnography for identifying sleep apnea in an attended setting and is potentially suitable for home-based automated assessment of sleep apnea in a population suspected of having sleep apnea. Heneghan C; Chua CP; Garvey JF; de Chazal P; Shouldice R; Boyle P; McNicholas WT. A portable automated assessment tool for sleep apnea using a combined holter-oximeter. SLEEP 2008;31(10):1432–1439.
- 1 October 2008
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 31 (10) , 1432-1439
Open AccessA Portable Automated Assessment Tool for Sleep Apnea Using a Combined Holter-Oximeter
Resource limitations have raised interest in portable monitoring systems that can be used by specialist sleep physicians as part of an overall strategy to improve access to the diagnosis of sleep apnea. This study validates a combined electrocardiogram and oximetry recorder (Holter-oximeter) against simultaneous polysomnography for detection of sleep apnea. Prospective study. A dedicated sleep disorders unit. 59 adults presenting for evaluation of suspected sleep apnea. NA. An automated algorithm previously developed for sleep apnea detection was applied to the electrocardiogram and oximetry measurements. The algorithm provides (a) epoch-by-epoch estimates of apnea occurrence and (b) estimates of overall per-subject AHI. Using separate thresholds of AHI ≥15 and AHI 20 and 0.04 respectively, with 16.7% of subjects having intermediate test results (AHI 5–14/h). Regardless of AHI, 85.3% of respiratory events were correctly annotated on an epoch-by-epoch basis. AHI underestimation bias was 0.9/h, and the antilogs of log-transformed limits of agreement were 0.3 and 2.7. Correlation between estimated and reference AHI was 0.95 (P < 0.001). Combined Holter-oximeter monitoring compares well with polysomnography for identifying sleep apnea in an attended setting and is potentially suitable for home-based automated assessment of sleep apnea in a population suspected of having sleep apnea. Heneghan C; Chua CP; Garvey JF; de Chazal P; Shouldice R; Boyle P; McNicholas WT. A portable automated assessment tool for sleep apnea using a combined holter-oximeter. SLEEP 2008;31(10):1432–1439.
- 15 June 2008
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 4 (3) , 223-228
Electrocardiogram Recording as a Screening Tool for Sleep Disordered Breathing
Transient changes in heart rate associated with obstructive apneas have been suggested for screening of sleep disordered breathing (SDB). This study prospe
- 15 June 2008
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 4 (3) , 223-228
Electrocardiogram Recording as a Screening Tool for Sleep Disordered Breathing
Transient changes in heart rate associated with obstructive apneas have been suggested for screening of sleep disordered breathing (SDB). This study prospe
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 405-407
MLSP Data Analysis Competition 2006: Denoising of Magnetoencephelographic Data
The study of human cognition, and preoperative functional brain mapping, are facilitated through the use of magnetoencephalography (MEG). However, the noise present in such recordings is significant relative to the signals of interest. To circumvent this issue multiple trials are performed for the same task and an ensemble average is performed to increase the signal-to-interference/noise ratio (SNIR). Unfortunately, perhaps 100-500 trials are required to achieve a sufficiently large SNIR. This paper describes a simple technique for improving the SNIR value given only 10 trials. The 10 trials from each of the 274 channels are first averaged. The 274 averaged channel estimates are then temporally low passed filtered, adjusting for the phase shift introduced by the filtering process. Finally, a spatial average is performed, where each channel is assigned the average value of itself and the three most similar channels. The three most similar channels are identified using correlation. The described method achieves an SNIR of 0.6 dB.
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 405-407
MLSP Data Analysis Competition 2006: Denoising of Magnetoencephelographic Data
The study of human cognition, and preoperative functional brain mapping, are facilitated through the use of magnetoencephalography (MEG). However, the noise present in such recordings is significant relative to the signals of interest. To circumvent this issue multiple trials are performed for the same task and an ensemble average is performed to increase the signal-to-interference/noise ratio (SNIR). Unfortunately, perhaps 100-500 trials are required to achieve a sufficiently large SNIR. This paper describes a simple technique for improving the SNIR value given only 10 trials. The 10 trials from each of the 274 channels are first averaged. The 274 averaged channel estimates are then temporally low passed filtered, adjusting for the phase shift introduced by the filtering process. Finally, a spatial average is performed, where each channel is assigned the average value of itself and the three most similar channels. The three most similar channels are identified using correlation. The described method achieves an SNIR of 0.6 dB.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 5117-5120
Continuous Blood Pressure Monitoring using ECG and Finger Photoplethysmogram
Pulse arrival time and the amplitude of the finger photoplethysmogram were used to track blood pressure continuously over 10-minute intervals. The measures were recorded with a holter-oximeter from a sample of 8 young, healthy human subjects in the supine and standing positions. Results indicate that, with individual calibration, systolic and diastolic blood pressure can be estimated with an average error of plusmn6 and plusmn4 mmHg respectively. Using pulse arrival time in combination with the amplitude of the finger photoplethysmogram gave better results than using any one alone, with PPG amplitude appearing to be more robust
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 5117-5120
Continuous Blood Pressure Monitoring using ECG and Finger Photoplethysmogram
Pulse arrival time and the amplitude of the finger photoplethysmogram were used to track blood pressure continuously over 10-minute intervals. The measures were recorded with a holter-oximeter from a sample of 8 young, healthy human subjects in the supine and standing positions. Results indicate that, with individual calibration, systolic and diastolic blood pressure can be estimated with an average error of plusmn6 and plusmn4 mmHg respectively. Using pulse arrival time in combination with the amplitude of the finger photoplethysmogram gave better results than using any one alone, with PPG amplitude appearing to be more robust
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5117-5120
Continuous Blood Pressure Monitoring using ECG and Finger Photoplethysmogram
Pulse arrival time and the amplitude of the finger photoplethysmogram were used to track blood pressure continuously over 10-minute intervals. The measures were recorded with a holter-oximeter from a sample of 8 young, healthy human subjects in the supine and standing positions. Results indicate that, with individual calibration, systolic and diastolic blood pressure can be estimated with an average error of plusmn6 and plusmn4 mmHg respectively. Using pulse arrival time in combination with the amplitude of the finger photoplethysmogram gave better results than using any one alone, with PPG amplitude appearing to be more robust
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5117-5120
Continuous Blood Pressure Monitoring using ECG and Finger Photoplethysmogram
Pulse arrival time and the amplitude of the finger photoplethysmogram were used to track blood pressure continuously over 10-minute intervals. The measures were recorded with a holter-oximeter from a sample of 8 young, healthy human subjects in the supine and standing positions. Results indicate that, with individual calibration, systolic and diastolic blood pressure can be estimated with an average error of plusmn6 and plusmn4 mmHg respectively. Using pulse arrival time in combination with the amplitude of the finger photoplethysmogram gave better results than using any one alone, with PPG amplitude appearing to be more robust
- Open Access
- 1 June 2004
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 27 (4) , 784-792
Detection of Obstructive Sleep Apnea in Pediatric Subjects using Surface Lead Electrocardiogram Features
To investigate the feasibility of detecting obstructive sleep apnea (OSA) in children using an automated classification system based on analysis of overnight electrocardiogram (ECG) recordings. Retrospective observational study. Fifty children underwent full overnight polysomnography. N/A. Expert polysomnography scoring was performed. The datasets were divided into a training set of 25 subjects (11 normal, 14 with OSA) and a withheld test set of 25 subjects (11 normal, 14 with OSA). Features, calculated from the ECG of the 25 training datasets, were empirically chosen to train a modified quadratic discriminant analysis classification system. The selected configuration used a segment length of 60 seconds and processed mean, SD, power spectral density, and serial correlation measures to classify segments as apneic or normal. By combining per-segment classifications and using receiveroperator characteristic analysis, a per-subject classifier was obtained that had a sensitivity of 85.7%, specificity of 90.9%, and accuracy of 88% on the training datasets. The same decision threshold was applied to the withheld datasets and yielded a sensitivity of 85.7%, specificity of 81.8%, and accuracy of 84%. The positive and negative predictive values were 85.7% and 81.8%, respectively, on the test dataset. The ability to correctly identify 12 out of 14 cases of OSA (with the 2 false negatives arising from subjects with an apnea-hypopnea index less than 10) indicates that the automated apnea classification system outlined may have clinical utility in pediatric patients.
- 1 June 2004
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 27 (4) , 784-792
Open AccessDetection of Obstructive Sleep Apnea in Pediatric Subjects using Surface Lead Electrocardiogram Features
To investigate the feasibility of detecting obstructive sleep apnea (OSA) in children using an automated classification system based on analysis of overnight electrocardiogram (ECG) recordings. Retrospective observational study. Fifty children underwent full overnight polysomnography. N/A. Expert polysomnography scoring was performed. The datasets were divided into a training set of 25 subjects (11 normal, 14 with OSA) and a withheld test set of 25 subjects (11 normal, 14 with OSA). Features, calculated from the ECG of the 25 training datasets, were empirically chosen to train a modified quadratic discriminant analysis classification system. The selected configuration used a segment length of 60 seconds and processed mean, SD, power spectral density, and serial correlation measures to classify segments as apneic or normal. By combining per-segment classifications and using receiveroperator characteristic analysis, a per-subject classifier was obtained that had a sensitivity of 85.7%, specificity of 90.9%, and accuracy of 88% on the training datasets. The same decision threshold was applied to the withheld datasets and yielded a sensitivity of 85.7%, specificity of 81.8%, and accuracy of 84%. The positive and negative predictive values were 85.7% and 81.8%, respectively, on the test dataset. The ability to correctly identify 12 out of 14 cases of OSA (with the 2 false negatives arising from subjects with an apnea-hypopnea index less than 10) indicates that the automated apnea classification system outlined may have clinical utility in pediatric patients.