Ho Seob Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ho Seob Kim has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
Dae-Wook Kim
Department of Physics and Nanoscience, Sun Moon University 1 , 70, Sunmoon-ro 221, Tangjeong-myeon, Asan-si, Chungcheongnam-do 31460, South Korea
20 shared publications- Young-Chul Kim
Department of Optometry, Eulji University, Seongnam 13135, Republic of Korea
14 shared publications Seungjoon Ahn
Department of Physics and Nanoscience, Sun Moon University 1 , 70, Sunmoon-ro 221, Tangjeong-myeon, Asan-si, Chungcheongnam-do 31460, South Korea
12 shared publicationsTae-Sik Oh
11 shared publications- Seong Joon Ahn
Sunmoon University
5 shared publications Young Chul Kim
Department of Optometry, Eulji University 2 , 553, Sanseong-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13135, South Korea
4 shared publications
Latest Publications
- Open Access
Raman Scattering Study on the Influence of E-Beam Bombardment on Si Electron Lens
Microcolumns have a stacked structure composed of an electron emitter, electron lens (source lens), einzel lens, and a deflector manufactured using a micro electro-mechanical system process. The electrons emitted from the tungsten field emitter mostly pass through the aperture holes. However, other electrons fail to pass through because of collisions around the aperture hole. We used Raman scattering measurements and X-ray photoelectron spectroscopy analyses to investigate the influence of electron beam bombardment on a Si electron lens irradiated by acceleration voltages of 0, 20, and 30 keV. We confirmed that the crystallinity was degraded, and carbon-related contamination was detected at the surface and edge of the aperture hole of the Si electron lens after electron bombardment for 24 h. Carbon-related contamination on the surface of the Si electron lens was verified by analyzing the Raman spectra of the carbon-deposited Si substrate using DC sputtering and a carbon rod sample. We report the crystallinity and the origin of the carbon-related contamination of electron Si lenses after electron beam bombardment by non-destructive Raman scattering and XPS analysis methods.
Open AccessRaman Scattering Study on the Influence of E-Beam Bombardment on Si Electron Lens
Microcolumns have a stacked structure composed of an electron emitter, electron lens (source lens), einzel lens, and a deflector manufactured using a micro electro-mechanical system process. The electrons emitted from the tungsten field emitter mostly pass through the aperture holes. However, other electrons fail to pass through because of collisions around the aperture hole. We used Raman scattering measurements and X-ray photoelectron spectroscopy analyses to investigate the influence of electron beam bombardment on a Si electron lens irradiated by acceleration voltages of 0, 20, and 30 keV. We confirmed that the crystallinity was degraded, and carbon-related contamination was detected at the surface and edge of the aperture hole of the Si electron lens after electron bombardment for 24 h. Carbon-related contamination on the surface of the Si electron lens was verified by analyzing the Raman spectra of the carbon-deposited Si substrate using DC sputtering and a carbon rod sample. We report the crystallinity and the origin of the carbon-related contamination of electron Si lenses after electron beam bombardment by non-destructive Raman scattering and XPS analysis methods.
- Open Access
Process Development for the Detoxification of Fermentation Inhibitors from Acid Pretreated Microalgae Hydrolysate
The aim of this study was to remove 5-hydroxymethyl furfural (5-HMF) and furfural, known as fermentation inhibitors, in acid pretreated hydrolysates (APH) obtained from Scenedesmus obliquus using activated carbon. Microwave-assisted pretreatment was used to produce APH containing glucose, xylose, and fermentation inhibitors (5-HMF, furfural). The response surface methodology was applied to optimize key detoxification variables such as temperature (16.5–58.5 °C), time (0.5–5.5 h), and solid–liquid (S-L) ratio of activated carbon (0.6–7.4 w/v%). Three variables showed significant effects on the removal of fermentation inhibitors. The optimum detoxification conditions with the maximum removal of fermentation inhibitors and the minimum loss of sugars (glucose and xylose) were as follows: temperature of 36.6 °C, extraction time of 3.86 h, and S-L ratio of 3.3 w/v%. Under these conditions, removal of 5-HMF, furfural, and sugars were 71.6, 83.1, and 2.44%, respectively, which agreed closely with the predicted values. When the APH and detoxified APH were used for ethanol fermentation by S. cerevisiae, the ethanol produced was 38.5% and 84.5% of the theoretical yields, respectively, which confirmed that detoxification using activated carbon was effective in removing fermentation inhibitors and increasing fermentation yield without significant removal of fermentable sugars.
Open AccessProcess Development for the Detoxification of Fermentation Inhibitors from Acid Pretreated Microalgae Hydrolysate
The aim of this study was to remove 5-hydroxymethyl furfural (5-HMF) and furfural, known as fermentation inhibitors, in acid pretreated hydrolysates (APH) obtained from Scenedesmus obliquus using activated carbon. Microwave-assisted pretreatment was used to produce APH containing glucose, xylose, and fermentation inhibitors (5-HMF, furfural). The response surface methodology was applied to optimize key detoxification variables such as temperature (16.5–58.5 °C), time (0.5–5.5 h), and solid–liquid (S-L) ratio of activated carbon (0.6–7.4 w/v%). Three variables showed significant effects on the removal of fermentation inhibitors. The optimum detoxification conditions with the maximum removal of fermentation inhibitors and the minimum loss of sugars (glucose and xylose) were as follows: temperature of 36.6 °C, extraction time of 3.86 h, and S-L ratio of 3.3 w/v%. Under these conditions, removal of 5-HMF, furfural, and sugars were 71.6, 83.1, and 2.44%, respectively, which agreed closely with the predicted values. When the APH and detoxified APH were used for ethanol fermentation by S. cerevisiae, the ethanol produced was 38.5% and 84.5% of the theoretical yields, respectively, which confirmed that detoxification using activated carbon was effective in removing fermentation inhibitors and increasing fermentation yield without significant removal of fermentable sugars.
- Open Access
Effect of Viscosity on the Formation of Porous Polydimethylsiloxane for Wearable Device Applications
Medical devices, which enhance the quality of life, have experienced a gradual increase in demand. Various research groups have attempted to incorporate soft materials such as skin into wearable devices. We developed a stretchable substrate with high elasticity by forming a porous structure on polydimethylsiloxane (PDMS). To optimize the porous structure, we propose a manufacturing process that utilizes a high-pressure steam with different viscosities (400, 800, 2100, and 3000 cP) of an uncured PDMS solution. The proposed method simplifies the manufacturing of porous structures and is cost-effective compared to other technologies. Porous structures of various viscosities were formed, and their electrical and mechanical properties evaluated. Porous PDMS (3000 cP) was formed in a sponge-like three-dimensional porous structure, compared to PDMS formed by other viscosities. The elongation of porous PDMS (3000 cP) was increased by up to 30%, and the relative resistance changed to less than 1000 times with the maximum strain test. The relative resistance increased the initial resistance (R0) by approximately 10 times during the 1500-times repeated cycling tests with 30% strain. As a result, patch-type wearable devices based on soft materials can provide an innovative platform that can connect with the human skin for robotics applications and for continuous health monitoring.
Open AccessEffect of Viscosity on the Formation of Porous Polydimethylsiloxane for Wearable Device Applications
Medical devices, which enhance the quality of life, have experienced a gradual increase in demand. Various research groups have attempted to incorporate soft materials such as skin into wearable devices. We developed a stretchable substrate with high elasticity by forming a porous structure on polydimethylsiloxane (PDMS). To optimize the porous structure, we propose a manufacturing process that utilizes a high-pressure steam with different viscosities (400, 800, 2100, and 3000 cP) of an uncured PDMS solution. The proposed method simplifies the manufacturing of porous structures and is cost-effective compared to other technologies. Porous structures of various viscosities were formed, and their electrical and mechanical properties evaluated. Porous PDMS (3000 cP) was formed in a sponge-like three-dimensional porous structure, compared to PDMS formed by other viscosities. The elongation of porous PDMS (3000 cP) was increased by up to 30%, and the relative resistance changed to less than 1000 times with the maximum strain test. The relative resistance increased the initial resistance (R0) by approximately 10 times during the 1500-times repeated cycling tests with 30% strain. As a result, patch-type wearable devices based on soft materials can provide an innovative platform that can connect with the human skin for robotics applications and for continuous health monitoring.
- 1 November 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (6) , 06J902
Variations of the field of view depending on the Si deflector shape in a microcolumn
A microcolumn is widely investigated as one of the strong candidates for multiple electron beam systems. In the microcolumn, one or two octupole deflectors are usually adopted to scan the electron beam, and the octupole deflector is assembled by placing eight deflector electrodes symmetrically around the electron beam path. The deflector electrodes are composed either of Mo rods or of Si electrodes fabricated through appropriate micro electro mechanical systems processes. Usually, to expand the field of view and reduce the electron beam distortion, the double-deflector method is used. However, the wiring for electrical connection to each electrode and the operation of the octupole deflector are rather complicated. In order to improve the assembly and performance of the octupole deflector, the authors devised a modified Si deflector and tested its performance.
- 1 November 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (6) , 06J902
Variations of the field of view depending on the Si deflector shape in a microcolumn
A microcolumn is widely investigated as one of the strong candidates for multiple electron beam systems. In the microcolumn, one or two octupole deflectors are usually adopted to scan the electron beam, and the octupole deflector is assembled by placing eight deflector electrodes symmetrically around the electron beam path. The deflector electrodes are composed either of Mo rods or of Si electrodes fabricated through appropriate micro electro mechanical systems processes. Usually, to expand the field of view and reduce the electron beam distortion, the double-deflector method is used. However, the wiring for electrical connection to each electrode and the operation of the octupole deflector are rather complicated. In order to improve the assembly and performance of the octupole deflector, the authors devised a modified Si deflector and tested its performance.
- 17 May 2017
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 56 (6S1) , 06GA02
Development of arrayed microcolumns and field emitters
Electron beam devices have been widely used for inspection or lithography processes. The multibeam technology based on arrayed microcolumns has been developed to overcome the low throughput issue. However, the multicolumn system has some drawbacks such as complexity, electron optics, and electron source. The first drawback is the difficulty in multicolumn assembly. In particular, the alignment process of a source lens and a tip requires sophisticated techniques. The second drawback is that the e-beam characteristics of microcolumns constituting the multicolumn differ from column to column. To solve the first drawback, a sub-5-nm-resolution probe beam optic design with a simple structure and a two-dimensional carbon nanotube (2D-CNT) electron emitter instead of the widely used tungsten field emitter tip have been studied.
- 17 May 2017
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 56 (6S1) , 06GA02
Development of arrayed microcolumns and field emitters
Electron beam devices have been widely used for inspection or lithography processes. The multibeam technology based on arrayed microcolumns has been developed to overcome the low throughput issue. However, the multicolumn system has some drawbacks such as complexity, electron optics, and electron source. The first drawback is the difficulty in multicolumn assembly. In particular, the alignment process of a source lens and a tip requires sophisticated techniques. The second drawback is that the e-beam characteristics of microcolumns constituting the multicolumn differ from column to column. To solve the first drawback, a sub-5-nm-resolution probe beam optic design with a simple structure and a two-dimensional carbon nanotube (2D-CNT) electron emitter instead of the widely used tungsten field emitter tip have been studied.
- 1 January 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (8) , 1690-1692
Comparison of Electron Emission Characteristics of W and CNT Field Emitter for Microcolumn
- 1 January 2017
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 29 (8) , 1690-1692
Comparison of Electron Emission Characteristics of W and CNT Field Emitter for Microcolumn
- 1 February 2016
- Published by American Scientific Publishers in Journal of Nanoelectronics and Optoelectronics
- Vol. 11 (1) , 46-50
Effect of Einzel Lens Electrode Spacing on Scan Range
A miniaturized microcolumn is a good candidate electron beam inspection instrument, due in great part to its large field of view. We investigated the effect of the Einzel lens electrode spacing on the electron beam scan range by simulation analysis. We analyzed the variations in potential distributions and electron beam properties due to varying the Einzel lens electrode spacing, and investigated their influence on the electron beam scan range.
- 1 February 2016
- Published by American Scientific Publishers in Journal of Nanoelectronics and Optoelectronics
- Vol. 11 (1) , 46-50
Effect of Einzel Lens Electrode Spacing on Scan Range
A miniaturized microcolumn is a good candidate electron beam inspection instrument, due in great part to its large field of view. We investigated the effect of the Einzel lens electrode spacing on the electron beam scan range by simulation analysis. We analyzed the variations in potential distributions and electron beam properties due to varying the Einzel lens electrode spacing, and investigated their influence on the electron beam scan range.
- 1 January 2015
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 27 (11) , 4247-4250
Advanced Operation of Microcolumn by Introducing Misalign Corrector
- 1 January 2015
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 27 (11) , 4247-4250
Advanced Operation of Microcolumn by Introducing Misalign Corrector
- 1 January 2014
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 26 (5) , 1417-1420
Key-Hole Type Quadrupole Lens Test for Advanced Operation of a Microcolumn
- 1 January 2014
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 26 (5) , 1417-1420
Key-Hole Type Quadrupole Lens Test for Advanced Operation of a Microcolumn
- Open Access
- 1 January 2014
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 26 (5) , 1408-1412
Scan Range Analysis According to Variation of Einzel Lens Electrode Gap in Microcolumn
- 1 January 2014
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 26 (5) , 1408-1412
Open AccessScan Range Analysis According to Variation of Einzel Lens Electrode Gap in Microcolumn