Hao Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hao Shen has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
X. Li
Applied Ion Beam Physics Laboratory, Institute of Modern Physics, Department of Nuclear Science and Technology, Fudan University, Shanghai 200433, China
3 shared publicationsY. Mi
Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433, China
3 shared publicationsY. Zheng
Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, China
3 shared publicationsA. Yamazaki
Department of Advanced Radiation Technology, Japan Atomic Energy Agency (JAEA), 1233 Watanuki-machi, Takasaki, Gunma 370-1292, Japan
2 shared publicationsH. Guo
Institute of Life Science, Shanghai Fisheries University, Shanghai 200090, PR China
2 shared publicationsHailei Zhang
Fudan Univ, Inst Modern Phys, Key Lab Nucl Phys & Ion beam Applicat, Shanghai 200433, Peoples R China
2 shared publications
Latest Publications
- 9 June 2026
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 69 (12) , 14854-14865
Development and Preclinical Evaluation of 68 Ga-Labeled B7-H3-Specific Bicyclic Peptides as Immuno-PET Tracers for Oncology
B7-H3 (CD276) is an emerging target for cancer theranostics, highlighting the need for imaging probes capable of noninvasively quantifying B7-H3 expression in tumors. Here, we developed three 68Ga-labeled B7-H3-targeting bicyclic peptide tracers with different PEG linker lengths. All tracers showed high radiochemical purity (>96%), favorable in vitro stability, and rapid blood clearance. Among them, [68Ga]Ga-B7H3-FZ1 exhibited the highest affinity (KD = 83.22 nM). Micro-PET/CT imaging demonstrated that tumor uptake of [68Ga]Ga-B7H3-FZ1 correlated positively with B7-H3 expression across multiple tumor models. In H1299 tumors. B7-H3 overexpression increased uptake from 1.09 ± 0.18 to 3.50 ± 0.97%ID/g at 30 min postinjection, confirming target specificity. Biosafety studies indicated no obvious toxicity. These results support [68Ga]Ga-B7H3-FZ1 as a promising PET tracer for noninvasive B7-H3 imaging.
- 9 June 2026
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 69 (12) , 14854-14865
Development and Preclinical Evaluation of 68 Ga-Labeled B7-H3-Specific Bicyclic Peptides as Immuno-PET Tracers for Oncology
B7-H3 (CD276) is an emerging target for cancer theranostics, highlighting the need for imaging probes capable of noninvasively quantifying B7-H3 expression in tumors. Here, we developed three 68Ga-labeled B7-H3-targeting bicyclic peptide tracers with different PEG linker lengths. All tracers showed high radiochemical purity (>96%), favorable in vitro stability, and rapid blood clearance. Among them, [68Ga]Ga-B7H3-FZ1 exhibited the highest affinity (KD = 83.22 nM). Micro-PET/CT imaging demonstrated that tumor uptake of [68Ga]Ga-B7H3-FZ1 correlated positively with B7-H3 expression across multiple tumor models. In H1299 tumors. B7-H3 overexpression increased uptake from 1.09 ± 0.18 to 3.50 ± 0.97%ID/g at 30 min postinjection, confirming target specificity. Biosafety studies indicated no obvious toxicity. These results support [68Ga]Ga-B7H3-FZ1 as a promising PET tracer for noninvasive B7-H3 imaging.
- Open Access
Enhancing Proton Therapy Efficacy Through Nanoparticle-Mediated Radiosensitization
Proton therapy, characterized by its unique Bragg peak, offers the potential to optimize the destruction of cancer cells while sparing healthy tissues, positioning it as one of the most advanced cancer treatment modalities currently available. However, in comparison to heavy ions, protons exhibit a relatively lower relative biological effectiveness (RBE), which limits the efficacy of proton therapy. The incorporation of nanoparticles for radiosensitization presents a novel approach to enhance the RBE of protons. This review provides a comprehensive discussion of the recent advancements in augmenting the biological effects of proton therapy through the use of nanoparticles. It examines the various types of nanoparticles that have been the focus of extensive research, elucidates their mechanisms of radiation sensitization, and evaluates the factors influencing the efficiency of this sensitization process. Furthermore, this review discusses the latest synergistic therapeutic strategies that integrate nanoparticle-mediated radiosensitization and outlines prospective directions for the future application of nanoparticles in conjunction with proton therapy.
Open AccessEnhancing Proton Therapy Efficacy Through Nanoparticle-Mediated Radiosensitization
Proton therapy, characterized by its unique Bragg peak, offers the potential to optimize the destruction of cancer cells while sparing healthy tissues, positioning it as one of the most advanced cancer treatment modalities currently available. However, in comparison to heavy ions, protons exhibit a relatively lower relative biological effectiveness (RBE), which limits the efficacy of proton therapy. The incorporation of nanoparticles for radiosensitization presents a novel approach to enhance the RBE of protons. This review provides a comprehensive discussion of the recent advancements in augmenting the biological effects of proton therapy through the use of nanoparticles. It examines the various types of nanoparticles that have been the focus of extensive research, elucidates their mechanisms of radiation sensitization, and evaluates the factors influencing the efficiency of this sensitization process. Furthermore, this review discusses the latest synergistic therapeutic strategies that integrate nanoparticle-mediated radiosensitization and outlines prospective directions for the future application of nanoparticles in conjunction with proton therapy.
- Open Access
- 17 May 2023
- Published by Springer Nature in Radiation Oncology
- Vol. 18 (1) , 1-10
Validation of the relative biological effectiveness of active-energy scanning carbon-ion radiotherapy on a commercial treatment planning system with a microdosimetic kinetic model
Background: The study objective was to validate the relative biological effectiveness (RBE) calculated by the modified microdosimetric kinetic model in RayStation (Ray-MKM) for active-energy scanning carbon-ion radiotherapy. Methods: The Ray-MKM was benchmarked using a spread-out Bragg-peak (SOBP) plan, which was suggested in literature from the National Institute of Radiobiological Science (NIRS) in Japan. The residual RBE differences from the MKM at NIRS (NIRS-MKM) were derived using several SOBP plans with different ranges, SOBP widths, and prescriptions. To investigate the origins of the differences, we compared the saturation-corrected dose-mean specific energy $$Z_{1D}^{*}$$ of the aforementioned SOBPs. Furthermore, we converted the RBE-weighted doses with the Ray-MKM to those with local effect model I (LEM doses). The purpose was to investigate whether the Ray-MKM could reproduce the RBE-weighted conversion study. Results: The benchmark determined the value of the clinical dose scaling factor, $$F_{clin}$$ , as 2.40. The target mean RBE deviations between the Ray-MKM and NIRS-MKM were median: 0.6 (minimum: 0.0 to maximum: 1.69) %. The $$Z_{1D}^{*}$$ difference in-depth led to the RBE difference in-depth and was remarkable at the distal end. The converted LEM doses from the Ray-MKM doses were comparable (the deviation being − 1.8–0.7%) to existing literature. Conclusion: This study validated the Ray-MKM based on our active-energy scanning carbon-ion beam via phantom studies. The Ray-MKM could generate similar RBEs as the NIRS-MKM after benchmarking. Analysis based on $$Z_{1D}^{*}$$ indicated that the different beam qualities and fragment spectra caused the RBE differences. Since the absolute dose differences at the distal end were small, we neglected them. Furthermore, each centre may determine its centre-specific $$F_{clin}$$ based on this approach.- 17 May 2023
- Published by Springer Nature in Radiation Oncology
- Vol. 18 (1) , 1-10
Open AccessValidation of the relative biological effectiveness of active-energy scanning carbon-ion radiotherapy on a commercial treatment planning system with a microdosimetic kinetic model
Background: The study objective was to validate the relative biological effectiveness (RBE) calculated by the modified microdosimetric kinetic model in RayStation (Ray-MKM) for active-energy scanning carbon-ion radiotherapy. Methods: The Ray-MKM was benchmarked using a spread-out Bragg-peak (SOBP) plan, which was suggested in literature from the National Institute of Radiobiological Science (NIRS) in Japan. The residual RBE differences from the MKM at NIRS (NIRS-MKM) were derived using several SOBP plans with different ranges, SOBP widths, and prescriptions. To investigate the origins of the differences, we compared the saturation-corrected dose-mean specific energy $$Z_{1D}^{*}$$ of the aforementioned SOBPs. Furthermore, we converted the RBE-weighted doses with the Ray-MKM to those with local effect model I (LEM doses). The purpose was to investigate whether the Ray-MKM could reproduce the RBE-weighted conversion study. Results: The benchmark determined the value of the clinical dose scaling factor, $$F_{clin}$$ , as 2.40. The target mean RBE deviations between the Ray-MKM and NIRS-MKM were median: 0.6 (minimum: 0.0 to maximum: 1.69) %. The $$Z_{1D}^{*}$$ difference in-depth led to the RBE difference in-depth and was remarkable at the distal end. The converted LEM doses from the Ray-MKM doses were comparable (the deviation being − 1.8–0.7%) to existing literature. Conclusion: This study validated the Ray-MKM based on our active-energy scanning carbon-ion beam via phantom studies. The Ray-MKM could generate similar RBEs as the NIRS-MKM after benchmarking. Analysis based on $$Z_{1D}^{*}$$ indicated that the different beam qualities and fragment spectra caused the RBE differences. Since the absolute dose differences at the distal end were small, we neglected them. Furthermore, each centre may determine its centre-specific $$F_{clin}$$ based on this approach. - Open Access
- 31 December 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-8
Calibration and evaluation of the relative biological effectiveness for carbon-ion radiotherapy in a new relative to a clinically applied treatment planning system
Background: The study objective was to validate the relative biological effectiveness (RBE) in RayStation for carbon-ion radiotherapy (CIRT) using the Syngo treatment planning system as reference. Methods: Local effect model I was established in RayStation (Ray-LEM) with the same parameters as in LEM I in Syngo (Syngo-LEM). Three cube plans covering most of the tumors treated at our center were generated with Syngo-LEM. Ray-LEM re-calculated the Syngo plans and compared the RBEs to the Syngo counterparts. The results showed that RayStation RBE was smaller than Syngo RBE. To ensure that Ray-LEM reproduced Syngo RBE, the observed deviations were used to scale the maximum RBE (RBEmax) in Ray-LEM. After this calibration, we further compared the RayStation RBE to Syngo RBE using additional plans in both homogeneous phantoms and patients, to ensure that the calibrated Ray-LEM reproduced Syngo RBE even with more complex planning features. Results: The calibration increased the RBEmax by 2.3% to raise the Ray-LEM RBE. The target mean RBE deviations in the phantom evaluation plans were median: 0.0 (minimum: − 1.1 to maximum: 0.7) %, and the target mean RBE deviations of the clinical target volumes of 16 patient cases were − 0.4 (− 1.5 to 0.2) %. Conclusions: The residual RBE difference between RayStation and Syngo was found to be ≤ 1.0%. Thus, we can propose to use RayStation for clinical CIRT treatment planning. However, the potential differences due to the absorbed beam model warrants further exploration.
- 31 December 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-8
Open AccessCalibration and evaluation of the relative biological effectiveness for carbon-ion radiotherapy in a new relative to a clinically applied treatment planning system
Background: The study objective was to validate the relative biological effectiveness (RBE) in RayStation for carbon-ion radiotherapy (CIRT) using the Syngo treatment planning system as reference. Methods: Local effect model I was established in RayStation (Ray-LEM) with the same parameters as in LEM I in Syngo (Syngo-LEM). Three cube plans covering most of the tumors treated at our center were generated with Syngo-LEM. Ray-LEM re-calculated the Syngo plans and compared the RBEs to the Syngo counterparts. The results showed that RayStation RBE was smaller than Syngo RBE. To ensure that Ray-LEM reproduced Syngo RBE, the observed deviations were used to scale the maximum RBE (RBEmax) in Ray-LEM. After this calibration, we further compared the RayStation RBE to Syngo RBE using additional plans in both homogeneous phantoms and patients, to ensure that the calibrated Ray-LEM reproduced Syngo RBE even with more complex planning features. Results: The calibration increased the RBEmax by 2.3% to raise the Ray-LEM RBE. The target mean RBE deviations in the phantom evaluation plans were median: 0.0 (minimum: − 1.1 to maximum: 0.7) %, and the target mean RBE deviations of the clinical target volumes of 16 patient cases were − 0.4 (− 1.5 to 0.2) %. Conclusions: The residual RBE difference between RayStation and Syngo was found to be ≤ 1.0%. Thus, we can propose to use RayStation for clinical CIRT treatment planning. However, the potential differences due to the absorbed beam model warrants further exploration.
- 3 July 2021
- Published by Springer Nature in Journal of Sol-Gel Science and Technology
- Vol. 99 (2) , 284-294
Fabrication and characterization of resorcinol–formaldehyde gradient aerogels by double-diffusive convection
- 3 July 2021
- Published by Springer Nature in Journal of Sol-Gel Science and Technology
- Vol. 99 (2) , 284-294
Fabrication and characterization of resorcinol–formaldehyde gradient aerogels by double-diffusive convection
- 2 March 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 493, 1-8
Reconstruction of hydrogen distribution in Inertial Confinement Fusion target shell by tomography with proton-proton scattering coincidence measurement
- 2 March 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 493, 1-8
Reconstruction of hydrogen distribution in Inertial Confinement Fusion target shell by tomography with proton-proton scattering coincidence measurement
- 12 December 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 348, 178-182
Nuclear microbeam analysis of ICF target material made by GDP technique
- 12 December 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 348, 178-182
Nuclear microbeam analysis of ICF target material made by GDP technique