Thomas R. Katona
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas R. Katona has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Brandon C. Parrish
Private Practice, Fort Wayne, Ind
1 shared publicationG. J. Eckert
Indiana University School of Medicine; IUPUI, Indianapolis, IN, USA
1 shared publicationHaihong Qian
1 shared publicationJie Chen
1 shared publicationKatherine S. Kula
Professor and Chair, Department of Orthodontics and Oral Facial Genetics, Indiana University School of Dentistry, IUPUI, Indianapolis, Ind
1 shared publicationKelton T. Stewart
Assistant Professor, Department of Orthodontics and Oral Facial Genetics, Indiana University School of Dentistry, IUPUI, Indianapolis, Ind
1 shared publication
Latest Publications
- 20 December 2012
- Published by Springer Nature in international journal of stomatology & occlusion medicine
- Vol. 6 (1) , 16-21
Engineering analyses of the link between occlusion and temporomandibular joint disorders
- 20 December 2012
- Published by Springer Nature in international journal of stomatology & occlusion medicine
- Vol. 6 (1) , 16-21
Engineering analyses of the link between occlusion and temporomandibular joint disorders
- 1 January 2012
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 82 (1) , 131-136
The effects of application time of a self-etching primer and debonding methods on bracket bond strength
Objective: To test the manufacturer's recommendation for the application rubbing time of a self-etching primer (Transbond Plus, 3M Unitek) and to compare the resulting bond strength of a resin composite (Transbond XT, 3M Unitek) in the traditional laboratory tension on all four wings with a simulation of the clinical single-wing lift-off debonding instrument (LODI; 3M Unitek). Materials and Methods: Flattened stainless-steel maxillary incisor orthodontic brackets (Victory Series, 3M Unitek) were bonded to 108 flattened bovine incisors. The enamel was rubbed with the self-etching primer for 0, 5 (the manufacturer's recommendation), and 10 seconds during a 10-second application. Traditional four-wing and LODI simulated debonding forces and the adhesive remnant index (ARI) were recorded. Results: One-way analysis of variance testing among rubbing times and debonding methods indicated a significant difference in strength with 0 and 5 seconds of rubbing and between traditional and LODI simulated tension. The bond strengths were higher in the ARI = 1 subset compared to the ARI = 3–5 subsets. Conclusions: The manufacturer's recommendation for primer rubbing time produced the highest bond strength. Less force is required for debonding when tension is applied to one wing (LODI simulation) vs on all four wings.
- 1 January 2012
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 82 (1) , 131-136
The effects of application time of a self-etching primer and debonding methods on bracket bond strength
Objective: To test the manufacturer's recommendation for the application rubbing time of a self-etching primer (Transbond Plus, 3M Unitek) and to compare the resulting bond strength of a resin composite (Transbond XT, 3M Unitek) in the traditional laboratory tension on all four wings with a simulation of the clinical single-wing lift-off debonding instrument (LODI; 3M Unitek). Materials and Methods: Flattened stainless-steel maxillary incisor orthodontic brackets (Victory Series, 3M Unitek) were bonded to 108 flattened bovine incisors. The enamel was rubbed with the self-etching primer for 0, 5 (the manufacturer's recommendation), and 10 seconds during a 10-second application. Traditional four-wing and LODI simulated debonding forces and the adhesive remnant index (ARI) were recorded. Results: One-way analysis of variance testing among rubbing times and debonding methods indicated a significant difference in strength with 0 and 5 seconds of rubbing and between traditional and LODI simulated tension. The bond strengths were higher in the ARI = 1 subset compared to the ARI = 3–5 subsets. Conclusions: The manufacturer's recommendation for primer rubbing time produced the highest bond strength. Less force is required for debonding when tension is applied to one wing (LODI simulation) vs on all four wings.
- 29 December 2011
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 39 (5) , 357-363
Do occlusal contact detection products alter the occlusion?
Clinicians rely on occlusal contact detection products to identify high contacts and to equilibrate occlusions. Concerns about these products have stimulated numerous investigations into marking reproducibility, accuracy and interpretation, but none have looked at their effects on the occlusion itself. The aim of this study was to assess whether these products alter the occlusion that they purport to measure by determining whether there are differences in the forces and moments experienced by occluding teeth with and without their presence. A matched pair of IPN Portrait 33° molar denture teeth was placed into occlusion with the mandibular tooth supported by a load sensor and the maxillary tooth mounted onto a vertically sliding assembly with a total weight of 15·1N. The three-dimensional force and moment components on the mandibular tooth were measured when the teeth were in direct crown-crown contact (control) and with the products in place. All six products, (Accufilm I, Accufilm II, Hanel Articulating Silk, Rudischhauser Thick and Thin, and T-scan) showed significant (P<0·05) differences in forces and moments from control.
- 29 December 2011
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 39 (5) , 357-363
Do occlusal contact detection products alter the occlusion?
Clinicians rely on occlusal contact detection products to identify high contacts and to equilibrate occlusions. Concerns about these products have stimulated numerous investigations into marking reproducibility, accuracy and interpretation, but none have looked at their effects on the occlusion itself. The aim of this study was to assess whether these products alter the occlusion that they purport to measure by determining whether there are differences in the forces and moments experienced by occluding teeth with and without their presence. A matched pair of IPN Portrait 33° molar denture teeth was placed into occlusion with the mandibular tooth supported by a load sensor and the maxillary tooth mounted onto a vertically sliding assembly with a total weight of 15·1N. The three-dimensional force and moment components on the mandibular tooth were measured when the teeth were in direct crown-crown contact (control) and with the products in place. All six products, (Accufilm I, Accufilm II, Hanel Articulating Silk, Rudischhauser Thick and Thin, and T-scan) showed significant (P<0·05) differences in forces and moments from control.
- Open Access
- 1 December 2011
- Published by Portico in Journal of Dental Biomechanics
- Vol. 2 (1) , 752741
A Qualitative Engineering Analysis of Occlusion Effects on Mandibular Fracture Repair Mechanics
Objectives. The purpose of this analytical study was to examine and critique the engineering foundations of commonly accepted biomechanical principles of mandible fracture repair. Materials and Methods. Basic principles of static equilibrium were applied to intact and plated mandibles, but instead of the traditional lever forces, the mandibles were subjected to more realistic occlusal forces. Results. These loading conditions produced stress distributions within the intact mandible that were very different and more complex than the customary lever-based gradient. The analyses also demonstrated the entirely different mechanical environments within intact and plated mandibles. Conclusions. Because the loading and geometry of the lever-idealized mandible is incomplete, the associated widely accepted bone stress distribution (tension on top and compression on the bottom) should not be assumed. Furthermore, the stress gradients within the bone of an intact mandible should not be extrapolated to the mechanical environment within the plated regions of a fractured mandible.
- 1 December 2011
- Published by Portico in Journal of Dental Biomechanics
- Vol. 2 (1) , 752741
Open AccessA Qualitative Engineering Analysis of Occlusion Effects on Mandibular Fracture Repair Mechanics
Objectives. The purpose of this analytical study was to examine and critique the engineering foundations of commonly accepted biomechanical principles of mandible fracture repair. Materials and Methods. Basic principles of static equilibrium were applied to intact and plated mandibles, but instead of the traditional lever forces, the mandibles were subjected to more realistic occlusal forces. Results. These loading conditions produced stress distributions within the intact mandible that were very different and more complex than the customary lever-based gradient. The analyses also demonstrated the entirely different mechanical environments within intact and plated mandibles. Conclusions. Because the loading and geometry of the lever-idealized mandible is incomplete, the associated widely accepted bone stress distribution (tension on top and compression on the bottom) should not be assumed. Furthermore, the stress gradients within the bone of an intact mandible should not be extrapolated to the mechanical environment within the plated regions of a fractured mandible.
- 1 June 2009
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 135 (6) , 696.e1-696.e8
An engineering analysis of dental occlusion principles
- 1 June 2009
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 135 (6) , 696.e1-696.e8
An engineering analysis of dental occlusion principles
- 1 December 2006
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 130 (6) , 698.e19-698.e27
Flaws in root resorption assessment algorithms: Role of tooth shape
- 1 December 2006
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 130 (6) , 698.e19-698.e27
Flaws in root resorption assessment algorithms: Role of tooth shape
- 1 January 2006
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 129 (1) , 54-59
The effects of first- and second-order gable bends on forces and moments generated by triangular loops
- 1 January 2006
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 129 (1) , 54-59
The effects of first- and second-order gable bends on forces and moments generated by triangular loops
- 1 January 2006
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 129 (1) , 60-64
Effect of loading mode on bond strength of orthodontic brackets bonded with 2 systems
- 1 January 2006
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 129 (1) , 60-64
Effect of loading mode on bond strength of orthodontic brackets bonded with 2 systems
- 1 December 2001
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 86 (6) , 636-643
A mathematical analysis of the role of friction in occlusal trauma
- 1 December 2001
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 86 (6) , 636-643
A mathematical analysis of the role of friction in occlusal trauma
- 1 September 2001
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 120 (3) , 263-271
A mechanism of noncontinuous supraosseous tooth eruption
- 1 September 2001
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 120 (3) , 263-271
A mechanism of noncontinuous supraosseous tooth eruption