Donald L. Russell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Donald L. Russell has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Chad E. English
Neptec Design Group Ltd., 302 Legget Drive, Ottawa, Ontario, Canada K2K 1Y5
2 shared publicationsMartin J. Conlon
Department of Mechanical and Aerospace Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, ON, K1S 5B6, Canada
1 shared publicationMegan McTavish
Canadian Intellectual Property Office, Industry Canada, Place du Portage I, 50 Victoria St., Room C-114, Gatineau, Quebec, Canada K1A 0C9
1 shared publicationTofy Mussivand
University of Ottawa Heart Institute
1 shared publication
Latest Publications
- 18 September 2009
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 1 (4) , 044501
Mechanical Issues Inherent in Antagonistically Actuated Systems
The relationship between the stiffness properties of actuators configured in an agonist-antagonist configuration and the stiffness of the joint is simple but not intuitively obvious. In this paper, this relationship is investigated and it is shown that the stiffness properties (hardening or softening) of the joint depend on the second derivative of the individual actuator stiffness with respect to actuator displacement. Numerical examples are given to illustrate the relationship and two practical examples, in which the actuators stiffness arises from Belleville washers or from an air piston, are analyzed.
- 18 September 2009
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 1 (4) , 044501
Mechanical Issues Inherent in Antagonistically Actuated Systems
The relationship between the stiffness properties of actuators configured in an agonist-antagonist configuration and the stiffness of the joint is simple but not intuitively obvious. In this paper, this relationship is investigated and it is shown that the stiffness properties (hardening or softening) of the joint depend on the second derivative of the individual actuator stiffness with respect to actuator displacement. Numerical examples are given to illustrate the relationship and two practical examples, in which the actuators stiffness arises from Belleville washers or from an air piston, are analyzed.
- 1 March 2008
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 43 (3) , 297-309
Representations of multi-joint stiffness for prosthetic limb design
- 1 March 2008
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 43 (3) , 297-309
Representations of multi-joint stiffness for prosthetic limb design
- 9 August 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 34 (9) , 1400-1413
Development of a Mathematical Model of the Human Circulatory System
A mathematical lumped parameter model of the human circulatory system (HCS) has been developed to complement in vitro testing of ventricular assist devices. Components included in this model represent the major parts of the systemic HCS loop, with all component parameters based on physiological data available in the literature. Two model configurations are presented in this paper, the first featuring elements with purely linear constitutive relations, and the second featuring nonlinear constitutive relations for the larger vessels. Three different aortic compliance functions are presented, and a pressure-dependent venous flow resistance is used to simulate venous collapse. The mathematical model produces reasonable systemic pressure and flow behaviour, and graphs of this data are included.
- 9 August 2006
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 34 (9) , 1400-1413
Development of a Mathematical Model of the Human Circulatory System
A mathematical lumped parameter model of the human circulatory system (HCS) has been developed to complement in vitro testing of ventricular assist devices. Components included in this model represent the major parts of the systemic HCS loop, with all component parameters based on physiological data available in the literature. Two model configurations are presented in this paper, the first featuring elements with purely linear constitutive relations, and the second featuring nonlinear constitutive relations for the larger vessels. Three different aortic compliance functions are presented, and a pressure-dependent venous flow resistance is used to simulate venous collapse. The mathematical model produces reasonable systemic pressure and flow behaviour, and graphs of this data are included.