Swapan Kumar Ghorai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Swapan Kumar Ghorai has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ajit Kumar
Department of Electronics & Communication, School of Engineering , 484700 Presidency University , Bengaluru , Karnataka , India
4 shared publications - Nishant Sharan
Department of ECE, SoE , Presidency University , Itgalpur Rajanakunte , Bengaluru , Karnataka , India
3 shared publications Mainak Basu
2 shared publications- Anupriya Singh1 shared publication
Ashish Kumar Sharma
1 shared publication- Bharat Gupta
National Institute of Technology Patna
1 shared publication
Latest Publications
- 24 April 2023
- Published by Springer Nature in Wireless Personal Communications
- Vol. 131 (2) , 1149-1165
Alleviating LED Nonlinearity in a HACO System Using a Blend of Precoder and a $\upmu$-Law Compander- 24 April 2023
- Published by Springer Nature in Wireless Personal Communications
- Vol. 131 (2) , 1149-1165
Alleviating LED Nonlinearity in a HACO System Using a Blend of Precoder and a $\upmu$-Law Compander- 29 August 2022
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 54 (10) , 1-21
Performance analysis of downlink multipath multi-user NOMA-VLC system
- 29 August 2022
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 54 (10) , 1-21
Performance analysis of downlink multipath multi-user NOMA-VLC system
- 24 August 2022
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 54 (10) , 1-13
LED non-linearity mitigation in a NOMA-OFDM VLC system using a union of precoder and companding
- 24 August 2022
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 54 (10) , 1-13
LED non-linearity mitigation in a NOMA-OFDM VLC system using a union of precoder and companding
- 31 May 2020
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 52 (6) , 1-14
PAPR reduction and non-linearity alleviation using hybrid of precoding and companding in a visible light communication (VLC) system
- 31 May 2020
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 52 (6) , 1-14
PAPR reduction and non-linearity alleviation using hybrid of precoding and companding in a visible light communication (VLC) system
- 8 April 2020
- Published by Springer Nature in Wireless Personal Communications
- Vol. 113 (4) , 2009-2026
Effect of LED Radiation Pattern on BER Performance in Indoor Multipath MIMO-VLC System
- 8 April 2020
- Published by Springer Nature in Wireless Personal Communications
- Vol. 113 (4) , 2009-2026
Effect of LED Radiation Pattern on BER Performance in Indoor Multipath MIMO-VLC System
- 6 April 2020
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 63 (2) , 273-283
Development of a Wearable Remote Cardiac Health Monitoring with Alerting System
Remote monitoring with alerting systems becomes unavoidable in the field of remote healthcare. The efficiency of such a system depends on accuracy, easy-to-use, versatility, and cost-effectiveness. In this study, a remote cardiac health monitoring along with the alert raising facility is presented. Special design techniques have been adopted to craft the photoplethysmography (PPG) sensor to overcome the congenital limitations like pressure disturbance, the influence of ambient light and motion artifacts. Three key components like pulse rate (PR), blood pressure (BP) and heart rate variability (HRV) are considered to monitor the cardiac health status. A novel algorithm has been developed to detect the cardiac health status of any subject from the above-mentioned physiological parameters. Also, the variation of human skin tone across demography is considered to minimize the impact of skin structure variability in PPG-based cardiac parameter measurement. Decentralized remote monitoring architecture is implemented using the virtual network computing (VNC) platform. We conducted a trial where the training dataset consisted of data from 70 volunteers and the trial dataset considered 20 new volunteers. The overall accuracy of cardiac health monitoring achieved is 98.5%. The experimental results demonstrate the good promise of reliable and efficient system architecture.
- 6 April 2020
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 63 (2) , 273-283
Development of a Wearable Remote Cardiac Health Monitoring with Alerting System
Remote monitoring with alerting systems becomes unavoidable in the field of remote healthcare. The efficiency of such a system depends on accuracy, easy-to-use, versatility, and cost-effectiveness. In this study, a remote cardiac health monitoring along with the alert raising facility is presented. Special design techniques have been adopted to craft the photoplethysmography (PPG) sensor to overcome the congenital limitations like pressure disturbance, the influence of ambient light and motion artifacts. Three key components like pulse rate (PR), blood pressure (BP) and heart rate variability (HRV) are considered to monitor the cardiac health status. A novel algorithm has been developed to detect the cardiac health status of any subject from the above-mentioned physiological parameters. Also, the variation of human skin tone across demography is considered to minimize the impact of skin structure variability in PPG-based cardiac parameter measurement. Decentralized remote monitoring architecture is implemented using the virtual network computing (VNC) platform. We conducted a trial where the training dataset consisted of data from 70 volunteers and the trial dataset considered 20 new volunteers. The overall accuracy of cardiac health monitoring achieved is 98.5%. The experimental results demonstrate the good promise of reliable and efficient system architecture.
- 1 April 2010
- Published by Elsevier in Optics Communications
- Vol. 283 (7) , 1278-1284
Phase retrieval in optical fiber modal interference for structural health monitoring
- 1 April 2010
- Published by Elsevier in Optics Communications
- Vol. 283 (7) , 1278-1284
Phase retrieval in optical fiber modal interference for structural health monitoring
- 8 May 2008
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 19 (6) , 065201
Distributed strain measurement using modal interference in a birefringent optical fiber
We propose a method based on modal interference in a birefringent optical fiber for distributed strain measurement. A frequency-modulated optical signal from a laser diode was launched in a birefringent fiber whose 'V' number was set in the range 2.405–3.831. The beat signal produced due to the interference of two lower order modes LP01 and LP11 was detected in a photodetector. The change in propagation constants between two modes under loading conditions leads to a phase variation of interference signal. The amplitude of the beat frequency was measured in the frequency domain by varying the modulating frequency, and it provides the measurand distribution along the beam. Results for strain distribution of a simply supported beam (51.0 cm × 3.0 cm × 0.6 cm) for an applied load of 250–1500 g are presented.
- 8 May 2008
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 19 (6) , 065201
Distributed strain measurement using modal interference in a birefringent optical fiber
We propose a method based on modal interference in a birefringent optical fiber for distributed strain measurement. A frequency-modulated optical signal from a laser diode was launched in a birefringent fiber whose 'V' number was set in the range 2.405–3.831. The beat signal produced due to the interference of two lower order modes LP01 and LP11 was detected in a photodetector. The change in propagation constants between two modes under loading conditions leads to a phase variation of interference signal. The amplitude of the beat frequency was measured in the frequency domain by varying the modulating frequency, and it provides the measurand distribution along the beam. Results for strain distribution of a simply supported beam (51.0 cm × 3.0 cm × 0.6 cm) for an applied load of 250–1500 g are presented.