Francis Kralick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Francis Kralick has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Gyu Man Kim
School of Mechanical Engineering, Kyungpook National University, Daegu, South Korea
1 shared publication Hongseok (Moses) Noh
Drexel University
1 shared publication- Hongseok (Moses) Noh
Mechanical Engineering and Mechanics, Drexel University, Philadelphia, PA 19104, USA
1 shared publication Jonghyun Oh
Drexel University
1 shared publication- Jonghyun Oh
Mechanical Engineering and Mechanics Department, Drexel University, Philadelphia, PA, USA
1 shared publication Robert Koenigsberg
1 shared publication
Latest Publications
- 13 January 2012
- Published by Springer Nature
- Vol. 114, 239-242
Micro-fabricated Shunt to Mimic Arachnoid Granulations for the Treatment of Communicating Hydrocephalus
Hydrocephalus is the abnormal accumulation of cerebrospinal fluid (CSF) within the confines of the skull that if left untreated results in significant morbidity and mortality. The treatment for hydrocephalus has remained essentially unchanged for over 50 years. It was a technological advance in materials that allowed John Holter, in conjunction with neurosurgeons Spitzer and Nulsen, to devise a valve and shunt system that diverted excess CSF from the ventricular space to the peritoneum. This ventriculo-peritoneal (VP) shunt is far from ideal, with problems associated with under/over shunting, mechanical mismatch, infection, high failure rates, disconnection and erosion. With the advances in the field of micro-fabrication and micro-machines we propose an innovative shunt system that would mimic the function of arachnoid granulations. This micro-fabricated shunting device, or micro-mechanical arachnoid granulation (MAG), consists of a multiplicity of micro-valves each 210 μm in diameter that each adhere to individual micro-needles. This work demonstrates the design and initial test results of the micro-valve with parameters for low cracking pressure, optimal flow rate, and reflux that would mimic the function of the native arachnoid granulations.
- 13 January 2012
- Published by Springer Nature
- Vol. 114, 239-242
Micro-fabricated Shunt to Mimic Arachnoid Granulations for the Treatment of Communicating Hydrocephalus
Hydrocephalus is the abnormal accumulation of cerebrospinal fluid (CSF) within the confines of the skull that if left untreated results in significant morbidity and mortality. The treatment for hydrocephalus has remained essentially unchanged for over 50 years. It was a technological advance in materials that allowed John Holter, in conjunction with neurosurgeons Spitzer and Nulsen, to devise a valve and shunt system that diverted excess CSF from the ventricular space to the peritoneum. This ventriculo-peritoneal (VP) shunt is far from ideal, with problems associated with under/over shunting, mechanical mismatch, infection, high failure rates, disconnection and erosion. With the advances in the field of micro-fabrication and micro-machines we propose an innovative shunt system that would mimic the function of arachnoid granulations. This micro-fabricated shunting device, or micro-mechanical arachnoid granulation (MAG), consists of a multiplicity of micro-valves each 210 μm in diameter that each adhere to individual micro-needles. This work demonstrates the design and initial test results of the micro-valve with parameters for low cracking pressure, optimal flow rate, and reflux that would mimic the function of the native arachnoid granulations.
- 27 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 20 (4) , 811-818
Design and Fabrication of a PDMS/Parylene Microvalve for the Treatment of Hydrocephalus
We present a novel microvalve for the treatment of a pathological condition, i.e., hydrocephalus. This microvalve is made of polydimethylsiloxane/Parylene composite layer which has a 3-D dome petal shape. This geometry enables the microvalve to rectify fluid flow in the forward and backward directions. New microfabrication techniques such as dome-shaped SU-8 mold fabrication and excimer laser machining for valve opening have been investigated to build the proposed microvalve. The pressure drop versus flow rate characteristics of the fabricated microvalve was investigated through in vitro flow tests. The flow test results showed that a 10 × 10 microvalve array with a cross-cut opening shape (200 × 60 μm) was found to be optimal for the treatment of hydrocephalus.
- 27 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 20 (4) , 811-818
Design and Fabrication of a PDMS/Parylene Microvalve for the Treatment of Hydrocephalus
We present a novel microvalve for the treatment of a pathological condition, i.e., hydrocephalus. This microvalve is made of polydimethylsiloxane/Parylene composite layer which has a 3-D dome petal shape. This geometry enables the microvalve to rectify fluid flow in the forward and backward directions. New microfabrication techniques such as dome-shaped SU-8 mold fabrication and excimer laser machining for valve opening have been investigated to build the proposed microvalve. The pressure drop versus flow rate characteristics of the fabricated microvalve was investigated through in vitro flow tests. The flow test results showed that a 10 × 10 microvalve array with a cross-cut opening shape (200 × 60 μm) was found to be optimal for the treatment of hydrocephalus.
- 1 December 2006
- Published by Elsevier in Surgical Neurology
- Vol. 66 (6) , 634-637
Sciatica in a patient with unusual peripheral nerve sheath tumors
- 1 December 2006
- Published by Elsevier in Surgical Neurology
- Vol. 66 (6) , 634-637
Sciatica in a patient with unusual peripheral nerve sheath tumors