BABijan Arjomandy

Bijan Arjomandy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bijan Arjomandy has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Christopher Ainsley

    University of Pennsylvania, Philadelphia, PA, USA

    1 shared publication
  • David Followill

    Imaging and Radiation Oncology Core (IROC) Houston, University of Texas MD Anderson Cancer Center, Houston, TX, USA

    1 shared publication
  • Ellen D. Yorke

    Memorial Sloan-Kettering Cancer Center, New York, NY, USA

    1 shared publication
  • Eric Klein

    Rhode Island Hospital, The Warren Alpert Medical School of Brown University, Providence, RI, USA

    1 shared publication
  • Jacob Flanz

    Massachusetts General Hospital, Burr Proton Therapy Center, Boston, MA

    1 shared publication
  • Jonathan B. Farr

    Applications of Detectors and Accelerators to Medicine, 1217, Meyrin, Switzerland

    1 shared publication

Latest Publications

  • Open Access

    AAPM task group 224: Comprehensive proton therapy machine quality assurance

    by Bijan Arjomandy, Paige Taylor, Christopher Ainsley, Sairos Safai, Narayan Sahoo, Mark Pankuch, Jonathan B. Farr, Sung Yong Park, Eric Klein, Jacob Flanz, et al.

    Purpose: Task Group (TG) 224 was established by the American Association of Physicists in Medicine's Science Council under the Radiation Therapy Committee and Work Group on Particle Beams. The group was charged with developing comprehensive quality assurance (QA) guidelines and recommendations for the three commonly employed proton therapy techniques for beam delivery: scattering, uniform scanning, and pencil beam scanning. This report supplements established QA guidelines for therapy machine performance for other widely used modalities, such as photons and electrons (TG 142, TG 40, TG 24, TG 22, TG 179, and Medical Physics Practice Guideline 2a) and shares their aims of ensuring the safe, accurate, and consistent delivery of radiation therapy dose distributions to patients. Methods: To provide a basis from which machine‐specific QA procedures can be developed, the report first describes the different delivery techniques and highlights the salient components of the related machine hardware. Depending on the particular machine hardware, certain procedures may be more or less important, and each institution should investigate its own situation. Results: In lieu of such investigations, this report identifies common beam parameters that are typically checked, along with the typical frequencies of those checks (daily, weekly, monthly, or annually). The rationale for choosing these checks and their frequencies is briefly described. Short descriptions of suggested tools and procedures for completing some of the periodic QA checks are also presented. Conclusion: Recommended tolerance limits for each of the recommended QA checks are tabulated, and are based on the literature and on consensus data from the clinical proton experience of the task group members. We hope that this and other reports will serve as a reference for clinical physicists wishing either to establish a proton therapy QA program or to evaluate an existing one.


  • EBT2 film as a depth-dose measurement tool for radiotherapy beams over a wide range of energies and modalities

    by Bijan Arjomandy, Ramesh Tailor, Li Zhao, Slobodan Devic

    Purpose: One of the fundamental parameters used for dose calculation is percentage depth-dose, generally measured employing ionization chambers. There are situations where use of ion chambers for measuring depth-doses is difficult or problematic. In such cases, radiochromic film might be an alternative. The EBT-2 model GAFCHROMIC™ film was investigated as a potential tool for depth-dose measurement in radiotherapybeams over a broad range of energies and modalities. Methods: Pieces of the EBT-2 model GAFCHROMIC™ EBT2 film were exposed to x-ray, electron, and protonbeams used in radiotherapy. The beams employed for this study included kilovoltage x-rays (75 kVp),60Co gamma-rays, megavoltage x-rays (18 MV), electrons (7 and 20 MeV), and pristine Bragg-peak protonbeams (126 and 152 MeV). At each beam quality, film response was measured over the dose range of 0.4–8.0 Gy, which corresponds to optical densities ranging from 0.05 to 0.4 measured with a flat-bed document scanner. To assess precision in depth-dose measurements with the EBT-2 model GAFCHROMIC™ film, uncertainty in measured optical density was investigated with respect to variation in film-to-film and scanner-bed uniformity. Results: For most beams, percentage depth-doses measured with the EBT-2 model GAFCHROMIC™ film show an excellent agreement with those measured with ion chambers. Some discrepancies are observed in case of (i) kilovoltage x-rays at larger depths due to beam-hardening, and (ii) protonbeams around Bragg-peak due to quenching effects. For these beams, an empirical polynomial correction produces better agreement with ion-chamber data. Conclusions: The EBT-2 model GAFCHROMIC™ film is an excellent secondary dosimeter for measurement of percentage depth-doses for a broad range of beam qualities and modalities used in radiotherapy. It offers an easy and efficient way to measure beam depth-dose data with a high spatial resolution.