Karolos Grigoriadis&ThinSpace
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Karolos Grigoriadis&ThinSpace has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Albert Franchek
Department of Mechanical and Aerospace Engineering, University of Houston, Houston, TX 77204, USA
14 shared publications - Javad Mohammadpour
University of Houston
4 shared publications - Reza Tafreshi
Department of Mechanical Engineering, Texas A&M University at Qatar, Doha, Qatar
4 shared publications - Amal Chebbi
Department of Mechanical Engineering, University of Houston, Houston, USA
3 shared publications Javad Mohammadpour
Department of Mechanical Engineering, University of Houston, Houston, TX 77204 USA
3 shared publications- Yingjie Tang
Department of Mechanical and Aerospace Engineering, University of Houston, Houston, TX 77204, USA
3 shared publications
Latest Publications
- Top Cited PapersOpen Access
Simultaneous State and Parameter Estimation Methods Based on Kalman Filters and Luenberger Observers: A Tutorial & Review
Simultaneous state and parameter estimation is essential for control system design and dynamic modeling of physical systems. This capability provides critical real-time insight into system behavior, supports the discovery of underlying mechanisms, and facilitates adaptive control strategies. Surveyed in this review paper are two classes of state and parameter estimation methods: Kalman Filters and Luenberger Observers. The Kalman Filter framework, including its major variants such as the Extended Kalman Filter (EKF), Unscented Kalman Filter (UKF), Cubature Kalman Filter (CKF), and Ensemble Kalman Filter (EnKF), has been widely applied for joint and dual estimation in linear and nonlinear systems under uncertainty. In parallel, Luenberger observers, typically used in deterministic settings, offer alternative approaches through high-gain, sliding mode, and adaptive observer structures. This review focuses on the theoretical foundations, algorithmic developments, and application domains of these methods and provides a comparative analysis of their advantages, limitations, and practical relevance across diverse engineering scenarios.
Top Cited PapersOpen AccessSimultaneous State and Parameter Estimation Methods Based on Kalman Filters and Luenberger Observers: A Tutorial & Review
Simultaneous state and parameter estimation is essential for control system design and dynamic modeling of physical systems. This capability provides critical real-time insight into system behavior, supports the discovery of underlying mechanisms, and facilitates adaptive control strategies. Surveyed in this review paper are two classes of state and parameter estimation methods: Kalman Filters and Luenberger Observers. The Kalman Filter framework, including its major variants such as the Extended Kalman Filter (EKF), Unscented Kalman Filter (UKF), Cubature Kalman Filter (CKF), and Ensemble Kalman Filter (EnKF), has been widely applied for joint and dual estimation in linear and nonlinear systems under uncertainty. In parallel, Luenberger observers, typically used in deterministic settings, offer alternative approaches through high-gain, sliding mode, and adaptive observer structures. This review focuses on the theoretical foundations, algorithmic developments, and application domains of these methods and provides a comparative analysis of their advantages, limitations, and practical relevance across diverse engineering scenarios.
- Open Access
- 3 July 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (3) , 1-16
Multi-Physics Modeling of Above-Ground Electromagnetic Inspection on Underground Pipeline
This study explores the effectiveness of electromagnetic-based non-destructive evaluation (NDE) for above-ground inspection of underground pipelines to detect corrosion defects. The above-ground electromagnetic inspection method involves measuring the magnetic field induced by an alternating current (AC) passed through the buried pipeline and analyzing the resulting electromagnetic field perturbations under various frequencies to identify defects. Finite Element Analysis (FEA) simulations using ANSYS Electronics Desktop were conducted to model the electromagnetic field around pipelines induced by a given AC signal with various frequencies through the pipeline with and without defects. The numerical simulations indicate the capability of detecting magnetic field perturbations caused by wall defects from above-ground sensors, even at a distance of one meter above the pipeline. However, sensing ability at the nano-Tesla level is required. The thresholds for such perturbations to indicate a pipeline defect were also numerically studied. The study also evaluated the impact of sensor movement and its sensitivity effect on the electromagnetic field and then the Low-High Frequency Method was introduced to mitigate potential false positives due to sensor displacement. The results highlight the potential of electromagnetic NDE for reliable and efficient pipeline monitoring, contributing to enhanced safety and operational efficiency in the oil and gas sector. Future experimental validation will be performed to validate the numerical solutions, quantify the effectiveness and optimize defect detection.
- 3 July 2025
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 44 (3) , 1-16
Open AccessMulti-Physics Modeling of Above-Ground Electromagnetic Inspection on Underground Pipeline
This study explores the effectiveness of electromagnetic-based non-destructive evaluation (NDE) for above-ground inspection of underground pipelines to detect corrosion defects. The above-ground electromagnetic inspection method involves measuring the magnetic field induced by an alternating current (AC) passed through the buried pipeline and analyzing the resulting electromagnetic field perturbations under various frequencies to identify defects. Finite Element Analysis (FEA) simulations using ANSYS Electronics Desktop were conducted to model the electromagnetic field around pipelines induced by a given AC signal with various frequencies through the pipeline with and without defects. The numerical simulations indicate the capability of detecting magnetic field perturbations caused by wall defects from above-ground sensors, even at a distance of one meter above the pipeline. However, sensing ability at the nano-Tesla level is required. The thresholds for such perturbations to indicate a pipeline defect were also numerically studied. The study also evaluated the impact of sensor movement and its sensitivity effect on the electromagnetic field and then the Low-High Frequency Method was introduced to mitigate potential false positives due to sensor displacement. The results highlight the potential of electromagnetic NDE for reliable and efficient pipeline monitoring, contributing to enhanced safety and operational efficiency in the oil and gas sector. Future experimental validation will be performed to validate the numerical solutions, quantify the effectiveness and optimize defect detection.
- Open Access
- 23 May 2024
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 133 (1-2) , 287
Correction to: Substrate temperature estimation and control in advanced MOCVD process for superconductor manufacturing
- 23 May 2024
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 133 (1-2) , 287
Open AccessCorrection to: Substrate temperature estimation and control in advanced MOCVD process for superconductor manufacturing
- 13 May 2024
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 133 (1-2) , 273-285
Substrate temperature estimation and control in advanced MOCVD process for superconductor manufacturing
- 13 May 2024
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 133 (1-2) , 273-285
Substrate temperature estimation and control in advanced MOCVD process for superconductor manufacturing
- Open Access
Hybrid Analytical Modeling of Force Dense Segmented Magnetic Linear Actuator with Non-Dimensional Parametric Modeling of the Magnetic Flux Effects
A new advanced two-dimensional hybrid analytical model of a segmented magnet linear actuator (MLA) comprised of surface permanent magnets (PM) is developed in this paper. This model is used to predict and evaluate the performance of the segmented MLA with proper correction on magnetic Flux Effects, validated by computational modeling. An MLA design with non-uniform PM segmentation was applied in this research to improve its performance compared with conventional radially magnetized MLA and uniform segmented Halbach Array based MLA. For MLA thrust force prediction, the previous published analytical model does not consider losses due to two observed magnetic Flux Effects: (1) the magnetic edge effect—the diminishing nature of the magnetic flux at the edge of the MLA, and (2) the observed magnetic interaction effect—the inconsistent peaks of individual magnetic flux lines, lower than the overall peak flux. In the proposed hybrid model for the segmented MLA, the shaft magnetic field distribution is based on a scalar potential theory subdomain method and the ring magnetic field is based on equivalent surface distributed currents. Collectively, these models are combined with three-dimensional finite element analysis (FEA), to estimate the magnetic thrust force. A data driven pole correction factor is introduced, based on the FEA computational database of three-dimensional MLA, to capture the losses associated with the magnetic flux, which is not considered in the analytical subdomain method. Finally, a normalized pole correction is proposed to generalize the model to different magnetic grades, different dimensional constraints, and varying magnet ratios of the segmented magnets. The developed model provides the design basis for manufacturing optimized force dense segmented MLAs for rotary to linear actuation, based on the force required for the application without the need for running FEA analysis after each design iteration, reducing costs and time required for the optimal design.
Open AccessHybrid Analytical Modeling of Force Dense Segmented Magnetic Linear Actuator with Non-Dimensional Parametric Modeling of the Magnetic Flux Effects
A new advanced two-dimensional hybrid analytical model of a segmented magnet linear actuator (MLA) comprised of surface permanent magnets (PM) is developed in this paper. This model is used to predict and evaluate the performance of the segmented MLA with proper correction on magnetic Flux Effects, validated by computational modeling. An MLA design with non-uniform PM segmentation was applied in this research to improve its performance compared with conventional radially magnetized MLA and uniform segmented Halbach Array based MLA. For MLA thrust force prediction, the previous published analytical model does not consider losses due to two observed magnetic Flux Effects: (1) the magnetic edge effect—the diminishing nature of the magnetic flux at the edge of the MLA, and (2) the observed magnetic interaction effect—the inconsistent peaks of individual magnetic flux lines, lower than the overall peak flux. In the proposed hybrid model for the segmented MLA, the shaft magnetic field distribution is based on a scalar potential theory subdomain method and the ring magnetic field is based on equivalent surface distributed currents. Collectively, these models are combined with three-dimensional finite element analysis (FEA), to estimate the magnetic thrust force. A data driven pole correction factor is introduced, based on the FEA computational database of three-dimensional MLA, to capture the losses associated with the magnetic flux, which is not considered in the analytical subdomain method. Finally, a normalized pole correction is proposed to generalize the model to different magnetic grades, different dimensional constraints, and varying magnet ratios of the segmented magnets. The developed model provides the design basis for manufacturing optimized force dense segmented MLAs for rotary to linear actuation, based on the force required for the application without the need for running FEA analysis after each design iteration, reducing costs and time required for the optimal design.
- Open Access
- 10 December 2021
- Published by Frontiers Media SA in Frontiers in Control Engineering
- Vol. 2
Observer-Based Control of LPV Systems with Input Delay and Saturation and Matched Disturbances via a Generalized Sector Condition
This paper examines the control design for parameter-dependent input-delay linear parameter-varying (LPV) systems with saturation constraints and matched input disturbances. A gain-scheduled dynamic output feedback controller, coupled with a disturbance observer to cancel out input disturbance effects, was augmented with an anti-windup compensator to locally stabilize the input-delay LPV system under saturation, model uncertainty, and exogenous disturbances. Sufficient delay-dependent conditions to asymptotically stabilize the closed-loop system were derived using Lyapunov-Krasovskii functionals and a modified generalized sector condition to address the input saturation nonlinearity. The level of disturbance rejection was characterized via the closed-loop induced-norm of the closed-loop system in the form of linear matrix inequality (LMI) constraints. The results are examined in the context of the mean arterial pressure (MAP) control in the clinical resuscitation of critical hypotensive patients. The MAP variation response to the injection of vasopressor drugs was modeled as an LPV system with a varying input delay and was susceptible to model uncertainty and input/output disturbances. A Bayesian filtering method known as the cubature Kalman filter (CKF) was used to estimate the instantaneous values of the parameters. The varying delay was estimated via a multiple-model approach. The proposed input-delay LPV control was validated in closed-loop simulations to demonstrate its merits and capabilities in the presence of drug administration constraints.- 10 December 2021
- Published by Frontiers Media SA in Frontiers in Control Engineering
- Vol. 2
Open AccessObserver-Based Control of LPV Systems with Input Delay and Saturation and Matched Disturbances via a Generalized Sector Condition
This paper examines the control design for parameter-dependent input-delay linear parameter-varying (LPV) systems with saturation constraints and matched input disturbances. A gain-scheduled dynamic output feedback controller, coupled with a disturbance observer to cancel out input disturbance effects, was augmented with an anti-windup compensator to locally stabilize the input-delay LPV system under saturation, model uncertainty, and exogenous disturbances. Sufficient delay-dependent conditions to asymptotically stabilize the closed-loop system were derived using Lyapunov-Krasovskii functionals and a modified generalized sector condition to address the input saturation nonlinearity. The level of disturbance rejection was characterized via the closed-loop induced-norm of the closed-loop system in the form of linear matrix inequality (LMI) constraints. The results are examined in the context of the mean arterial pressure (MAP) control in the clinical resuscitation of critical hypotensive patients. The MAP variation response to the injection of vasopressor drugs was modeled as an LPV system with a varying input delay and was susceptible to model uncertainty and input/output disturbances. A Bayesian filtering method known as the cubature Kalman filter (CKF) was used to estimate the instantaneous values of the parameters. The varying delay was estimated via a multiple-model approach. The proposed input-delay LPV control was validated in closed-loop simulations to demonstrate its merits and capabilities in the presence of drug administration constraints. - Open Access
Low Pressure Experimental Validation of Low-Dimensional Analytical Model for Air–Water Two-Phase Transient Flow in Horizontal Pipelines
This paper presents a low-pressure experimental validation of a two-phase transient pipeline flow model. Measured pressure and flow rate data are collected for slug and froth flow patterns at the low pressure of 6 bar at the National University of Singapore Multiphase Flow Loop facility. The analyzed low-dimensional model proposed in comprises a steady-state multiphase flow model in series with a linear dynamic model capturing the flow transients. The model is based on a dissipative distributed parameter model for transient flow in transmission lines employing equivalent fluid properties. These parameters are based solely on the flowing conditions, fluid properties and pipeline geometry. OLGA simulations are employed as an independent method to validate the low-dimension model. Both low-dimensional and OLGA models are evaluated based on the estimated two-phase pressure transients for varying gas volume fraction (GVF). Both models estimated the two-phase flow transient pressure within 5% mean absolute percent error of the laboratory data. Additionally, an unavoidable presence of entrained air within a pipeline is confirmed for the case of 0% GVF as evidenced by the pressure transient estimation. Thus, dampened oscillations in the simulated 0% GVF case exists owing to an increase in the fluid compressibility.
Open AccessLow Pressure Experimental Validation of Low-Dimensional Analytical Model for Air–Water Two-Phase Transient Flow in Horizontal Pipelines
This paper presents a low-pressure experimental validation of a two-phase transient pipeline flow model. Measured pressure and flow rate data are collected for slug and froth flow patterns at the low pressure of 6 bar at the National University of Singapore Multiphase Flow Loop facility. The analyzed low-dimensional model proposed in comprises a steady-state multiphase flow model in series with a linear dynamic model capturing the flow transients. The model is based on a dissipative distributed parameter model for transient flow in transmission lines employing equivalent fluid properties. These parameters are based solely on the flowing conditions, fluid properties and pipeline geometry. OLGA simulations are employed as an independent method to validate the low-dimension model. Both low-dimensional and OLGA models are evaluated based on the estimated two-phase pressure transients for varying gas volume fraction (GVF). Both models estimated the two-phase flow transient pressure within 5% mean absolute percent error of the laboratory data. Additionally, an unavoidable presence of entrained air within a pipeline is confirmed for the case of 0% GVF as evidenced by the pressure transient estimation. Thus, dampened oscillations in the simulated 0% GVF case exists owing to an increase in the fluid compressibility.
- Open Access
Real-Time Cubature Kalman Filter Parameter Estimation of Blood Pressure Response Characteristics Under Vasoactive Drugs Administration
Mathematical modeling and real-time dynamics identification of the mean arterial blood pressure (MAP) response of a patient to vasoactive drug infusion can provide a reliable tool for automated drug administration and therefore, reduce the emergency costs and significantly benefit the patient's MAP regulation in an intensive care unit. To this end, a dynamic first-order linear parameter-varying (LPV) model with varying parameters and varying input delay is considered to capture the MAP response dynamics. Such a model effectively addresses the complexity and the intra- and inter-patient variability of the physiological response. We discretize the model and augment the state vector with model parameters as unknown states of the system and a Bayesian-based multiple-model square root cubature Kalman filtering (MMSRCKF) approach is utilized to estimate the model time-varying parameters. Since, unlike the other model parameters, the input delay cannot be captured by a random-walk process, a multiple-model module with a posterior probability estimation is implemented to provide the delay identification. Validation results confirm the effectiveness of the proposed identification algorithm both in simulation scenarios and also using animal experiment data.
Open AccessReal-Time Cubature Kalman Filter Parameter Estimation of Blood Pressure Response Characteristics Under Vasoactive Drugs Administration
Mathematical modeling and real-time dynamics identification of the mean arterial blood pressure (MAP) response of a patient to vasoactive drug infusion can provide a reliable tool for automated drug administration and therefore, reduce the emergency costs and significantly benefit the patient's MAP regulation in an intensive care unit. To this end, a dynamic first-order linear parameter-varying (LPV) model with varying parameters and varying input delay is considered to capture the MAP response dynamics. Such a model effectively addresses the complexity and the intra- and inter-patient variability of the physiological response. We discretize the model and augment the state vector with model parameters as unknown states of the system and a Bayesian-based multiple-model square root cubature Kalman filtering (MMSRCKF) approach is utilized to estimate the model time-varying parameters. Since, unlike the other model parameters, the input delay cannot be captured by a random-walk process, a multiple-model module with a posterior probability estimation is implemented to provide the delay identification. Validation results confirm the effectiveness of the proposed identification algorithm both in simulation scenarios and also using animal experiment data.
- 10 October 2018
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 141 (2)
Full- and Reduced-Order Fault Detection Filter Design With Application in Flow Transmission Lines
The full- and reduced-order fault detection filter design is examined for fault diagnosis in linear time-invariant (LTI) systems in the presence of noise and disturbances. The fault detection filter design problem is formulated as an H∞ problem using a linear fractional transformation (LFT) framework and the solution is based on the bounded real lemma (BRL). Necessary and sufficient conditions for the existence of the fault detection filter are presented in the form of linear matrix inequalities (LMIs) resulting in a convex problem for the full-order filter design and a rank-constrained nonconvex problem for the reduced-order filter design. By minimizing the sensitivity of the filter residuals to noise and disturbances, the fault detection objective is fulfilled. A reference model can be incorporated in the design in order to shape the desired performance of the fault detection filter. The proposed fault detection and isolation (FDI) framework is applied to detect instrumentation and sensor faults in fluid transmission and pipeline systems. To this end, a lumped parameter framework for modeling infinite-dimensional fluid transient systems is utilized and a low-order model is obtained to pursue the instrumentation fault diagnosis objective. Full- and reduced-order filters are designed for sensor FDI. Simulations are conducted to assess the effectiveness of the proposed fault detection approach.
- 10 October 2018
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 141 (2)
Full- and Reduced-Order Fault Detection Filter Design With Application in Flow Transmission Lines
The full- and reduced-order fault detection filter design is examined for fault diagnosis in linear time-invariant (LTI) systems in the presence of noise and disturbances. The fault detection filter design problem is formulated as an H∞ problem using a linear fractional transformation (LFT) framework and the solution is based on the bounded real lemma (BRL). Necessary and sufficient conditions for the existence of the fault detection filter are presented in the form of linear matrix inequalities (LMIs) resulting in a convex problem for the full-order filter design and a rank-constrained nonconvex problem for the reduced-order filter design. By minimizing the sensitivity of the filter residuals to noise and disturbances, the fault detection objective is fulfilled. A reference model can be incorporated in the design in order to shape the desired performance of the fault detection filter. The proposed fault detection and isolation (FDI) framework is applied to detect instrumentation and sensor faults in fluid transmission and pipeline systems. To this end, a lumped parameter framework for modeling infinite-dimensional fluid transient systems is utilized and a low-order model is obtained to pursue the instrumentation fault diagnosis objective. Full- and reduced-order filters are designed for sensor FDI. Simulations are conducted to assess the effectiveness of the proposed fault detection approach.
- 28 August 2017
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 140 (1)
Transmission Line Modeling of Inclined Compressible Fluid Flows
Compressible fluid flow modeling for inclined lines is a challenging phenomenon due to the nonlinearity of the governing equations and the spatial–temporal dependency of the fluid density. In this paper, the transmission line analytical model is applied to the determination of inclined compressible fluid flow's dynamics. To establish this model, an exact transcendent solution is developed by solving the Navier–Stokes equation in the Laplace domain. A transfer function approximation, allowing the fluid flow transients determination, is recovered from the exact solution using residual calculations. The error resulting from the polynomial fraction approximation of the transfer functions is circumvented through frequency response corrections for the approximation to meet the exact function steady-state behavior. The effect of gravity and fluid compressibility on the fluid flow dynamics as well as the interplay between those two factors are illustrated through the pressure and flow rate's frequency and time responses.
- 28 August 2017
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 140 (1)
Transmission Line Modeling of Inclined Compressible Fluid Flows
Compressible fluid flow modeling for inclined lines is a challenging phenomenon due to the nonlinearity of the governing equations and the spatial–temporal dependency of the fluid density. In this paper, the transmission line analytical model is applied to the determination of inclined compressible fluid flow's dynamics. To establish this model, an exact transcendent solution is developed by solving the Navier–Stokes equation in the Laplace domain. A transfer function approximation, allowing the fluid flow transients determination, is recovered from the exact solution using residual calculations. The error resulting from the polynomial fraction approximation of the transfer functions is circumvented through frequency response corrections for the approximation to meet the exact function steady-state behavior. The effect of gravity and fluid compressibility on the fluid flow dynamics as well as the interplay between those two factors are illustrated through the pressure and flow rate's frequency and time responses.