RARami J. Abboud

Rami J. Abboud

*This is an algorithmically generated author record based on publicly available information.

Rami J. Abboud has a total of 54 co-authors. Here are the top co-authors by number of shared publications:

  • Graham Arnold

    Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, University of Dundee, Dundee DD1 9SY, UK

    6 shared publications
  • Lynda Cochrane

    4 shared publications
  • Weijie Wang

    Institute of Motion Analysis Research (IMAR), Department of Orthopaedic and Trauma Surgery, TORT Centre, Ninewells Hospital & Medical School, University of Dundee, Dundee, Scotland

    4 shared publications
  • Weijie Wang

    Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, University of Dundee, Dundee DD1 9SY, UK

    4 shared publications
  • Graham P Arnold

    Institute of Motion Analysis Research (IMAR), Department of Orthopaedic and Trauma Surgery, TORT Centre, Ninewells Hospital & Medical School, University of Dundee, Dundee, Scotland

    3 shared publications
  • Tim S Drew

    Institute of Motion Analysis Research (IMAR), Department of Orthopaedic and Trauma Surgery, TORT Centre, Ninewells Hospital & Medical School, University of Dundee, Dundee, Scotland

    3 shared publications

Latest Publications

  • Short term results of reverse total shoulder arthroplasty

    by Aditya K. Agrawal, Carlos Wigderowitz, Bruno Ribeiro, Amar Malhas, Abhishek Vaish, Rami Abboud


  • Open Access

    Comparison of branded rugby headguards on their effectiveness in reducing impact on the head

    by Erin R A Frizzell, Graham P Arnold, Weijie Wang, Rami J Abboud, Tim S Drew

    Aim To compare the available brands of rugby headguards and evaluate their impact attenuation properties at various locations on the cranium, with regard to concussion prevention. Methods Seven different branded headguards were fitted onto a rigid headform and drop-tested in three different positions. An accelerometer measured the linear acceleration the headform experienced on impact with the ground. Each test involved dropping the headform from a height that generated 103.8 g on average when bare, which is the closest acceleration to the upper limit of the concussion threshold of 100 g. A mean peak acceleration for each drop position was calculated and compared with the bare baseline measurement. Results Each headguard demonstrated a significant decrease in the mean peak acceleration from the baseline value (all p≤0.01). Overall the Canterbury Ventilator was the most effective headguard, decreasing the impact force on average by 47%. The least effective was the XBlades Elite headguard, averaging a force reduction of 27%. In five of the seven headguards, the right side of the headwear was the most effective at reducing impact force. Conclusion Overall, the results indicate that it would be beneficial to wear a headguard during rugby in order to reduce the impact forces involved in head collisions. There was also a clear difference in performance between the tested brands, establishing the Canterbury headguard as the most effective. However, only one model of headguard from each brand was tested, so further research evaluating all other models should be considered.


  • Open Access

    Establishing state of motion through two-dimensional foot and shoe print analysis: A pilot study

    by Fernando Bueno Neves, Graham P. Arnold, Sadiq Nasir, Weijie Wang, Calum MacDonald, Ian Christie, Rami J. Abboud


  • Open Access

    A pilot biomechanical assessment of curling deliveries: is toe sliding more likely to cause knee injury than flatfoot sliding?

    by Iona Robertson, Graham P Arnold, Weijie Wang, Tim S Drew, Sadiq Nasir, Calum MacDonald, Rami J Abboud

    Background The aim of this study was to determine whether toe sliding is more likely to cause knee injuries than flatfoot sliding in curling. Methods Twelve curlers participated in the study, each delivering 12 stones. Six stones per volunteer were delivered using a flatfoot slide and six were delivered using a toe slide. The Pedar-X in-shoe pressure system recorded the plantar pressure during each of the slides, while a sagittal plane digital video recorded the body position of the curler. Measurements were taken from the video recordings using a software overlay program (MB Ruler), and this, combined with the Pedar-X data, gave the overall joint force in the tuck knee. Results The knee joint force for toe sliding was more than double that of flatfoot sliding (pConclusion Injuries are more likely to occur in toe sliding, compared with flatfoot sliding, due to the increase in force and moment, pushing the weight of the curler forward over the knee, which could make the adopted position less stable. Curlers might consider avoiding toe sliding to reduce the risk of knee injuries if the two types of delivery could be performed equally well.


  • Racquet string tension directly affects force experienced at the elbow: implications for the development of lateral epicondylitis in tennis players

    by Badri R Mohandhas, Navnit Makaram, Tim S Drew, Weijie Wang, Graham P Arnold, Rami J Abboud

    Background: Lateral epicondylitis (LE) occurs in almost half of all tennis players. Racket-string tension is considered to be an important factor influencing the development of LE. No literature yet exists that substantiates how string-tension affects force transmission to the elbow, as implicated in LE development. We establish a quantitative relationship between string-tension and elbow loading, analyzing tennis strokes using rackets with varying string-tensions. Methods: Twenty recreational tennis players simulated backhand tennis strokes using three rackets strung at tensions of 200 N, 222 N and 245 N. Accelerometers recorded accelerations at the elbow, wrist and racket handle. Average peak acceleration was determined to correlate string-tension with elbow loading. Results: Statistically significant differences ( p < 0.05) were observed when average peak acceleration at the elbow at 200 N string-tension (acceleration of 5.58 m/s2) was compared with that at 222 N tension (acceleration of 6.83 m/s2) and 245 N tension (acceleration of 7.45 m/s2). The 200 N racket induced the least acceleration at the elbow. Conclusions: Although parameters determining force transmission to the elbow during a tennis stroke are complex, the present study was able to control these parameters, isolating the effect of string-tension. Lower string-tensions transmit less force to the elbow in backhand strokes. Reducing string-tension should be considered favourably with respect to reducing the risk of developing LE.


  • Footwear in rock climbing: Current practice

    by R.D. McHenry, G.P. Arnold, W. Wang, R.J. Abboud


  • Dynamic pressure effect on horse and horse rider during riding

    by Graeme Nicol, Graham P. Arnold, Weijie Wang, Rami J. Abboud


  • Open Access

    Dynamic 3D shape of the plantar surface of the foot using coded structured light: a technical report

    by Ali K Thabet, Emanuele Trucco, Joaquim Salvi, Weijie Wang, Rami J Abboud

    Background: The foot provides a crucial contribution to the balance and stability of the musculoskeletal system, and accurate foot measurements are important in applications such as designing custom insoles/footwear. With better understanding of the dynamic behavior of the foot, dynamic foot reconstruction techniques are surfacing as useful ways to properly measure the shape of the foot. This paper presents a novel design and implementation of a structured‐light prototype system providing dense three dimensional (3D) measurements of the foot in motion. The input to the system is a video sequence of a foot during a single step; the output is a 3D reconstruction of the plantar surface of the foot for each frame of the input.Methods: Engineering and clinical tests were carried out to test the accuracy and repeatability of the system. Accuracy experiments involved imaging a planar surface from different orientations and elevations and measuring the fitting errors of the data to a plane. Repeatability experiments were done using reconstructions from 27 different subjects, where for each one both right and left feet were reconstructed in static and dynamic conditions over two different days.Results: The static accuracy of the system was found to be 0.3 mm with planar test objects. In tests with real feet, the system proved repeatable, with reconstruction differences between trials one week apart averaging 2.4 mm (static case) and 2.8 mm (dynamic case).Conclusion: The results obtained in the experiments show positive accuracy and repeatability results when compared to current literature. The design also shows to be superior to the systems available in the literature in several factors. Further studies need to be done to quantify the reliability of the system in clinical environments.


  • Energy consumption during simulated minimal access surgery with and without using an armrest

    by Mansoor Jafri, Stuart Brown, Graham Arnold, Rami Abboud, Weijie Wang

    Minimal access surgery (MAS) can be a lengthy procedure when compared to open surgery and therefore surgeon fatigue becomes an important issue and surgeons may expose themselves to chronic injuries and making errors. There have been few studies on this topic and they have used only questionnaires and electromyography rather than direct measurement of energy expenditure (EE). The aim of this study was to investigate whether the use of an armrest could reduce the EE of surgeons during MAS. Sixteen surgeons performed simulated MAS with and without using an armrest. They were required to perform the time-consuming task of using scissors to cut a rubber glove through its top layer in a triangular fashion with the help of a laparoscopic camera. Energy consumptions were measured using the Oxycon® Mobile system during all the procedures. Error rate and duration time for simulated surgery were recorded. After performing the simulated surgery, subjects scored how comfortable they felt using the armrest. It was found that O2 uptake (VO2) was 5 % less when surgeons used the armrest. The error rate when performing the procedure with the armrest was 35 % compared with 42.29 % without the armrest. Additionally, comfort levels with the armrest were higher than without the armrest. 75 % of surgeons indicated a preference for using the armrest during the simulated surgery. The armrest provides support for surgeons and cuts energy consumption during simulated MAS.