François Philippon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
François Philippon has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Marcel Gilbert
4 shared publicationsGilles O'Hara
3 shared publicationsJean Champagne
Quebec Heart and Lung Institute, Ste-Foy, Canada
3 shared publications- Jean Champagne
Quebec Heart and Lung Institute, Laval University, Quebec City, QC, Canada (J.R.-C., J.-M.P., J.C., P.V.-C., M.C., G.O., E.S.).
3 shared publications Denis Desaulniers
Quebec Heart Institute, Quebec, Canada
2 shared publicationsJean G. Dumesnil
2 shared publications
Latest Publications
- Open Access
- 1 September 2016
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 2 (5) , 399-403
Wolff-Parkinson-White as a bystander in a patient with aborted sudden cardiac death
- 1 September 2016
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 2 (5) , 399-403
Open AccessWolff-Parkinson-White as a bystander in a patient with aborted sudden cardiac death
- Open Access
- 30 October 2008
- Published by Bentham Science Publishers Ltd. in The Open Pacing, Electrophysiology & Therapy Journal
- Vol. 1 (1) , 1-5
Long Term Follow-Up After Atrioventricular Node Ablation and Right Ventricular Pacing: Effects on Clinical Events and Left Ventricular Function
- 30 October 2008
- Published by Bentham Science Publishers Ltd. in The Open Pacing, Electrophysiology & Therapy Journal
- Vol. 1 (1) , 1-5
Open AccessLong Term Follow-Up After Atrioventricular Node Ablation and Right Ventricular Pacing: Effects on Clinical Events and Left Ventricular Function
- 1 October 2007
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 23, 5B-8B
The Quebec Heart Institute: 50 years of excellence in cardiology
- 1 October 2007
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 23, 5B-8B
The Quebec Heart Institute: 50 years of excellence in cardiology
- Open Access
- 1 January 2005
- Published by Springer Nature in BMC Medicine
- Vol. 3 (1) , 1
Recurrent cardiac events in patients with idiopathic ventricular fibrillation, excluding patients with the Brugada syndrome
Background: The recurrence of cardiac events in patients with idiopathic ventricular fibrillation (VF) excluding patients with the Brugada syndrome is unclear since this entity remains present in previous studies. Methods: Since 1992, 18 patients (72% male) with idiopathic VF out of 455 ICD implants were treated with an implantable cardioverter defibrillator (ICD). The mean age at first ICD implantation was 42 ± 14 years. Brugada syndrome, as well as other primary electrical diseases (e.g. long QT), were systematically excluded in all patients by the absence of the typical electrocardiogram (ST elevation in the right precordial leads) at rest and/or after pharmacological tests (ajmaline, flecainide, or procainamide). Recurrence of cardiac events was prospectively assessed. Results: During a mean follow-up period of 41 ± 27 months, VF recurrence with appropriate shock occurred in 7 patients (39%) covering a total of 27 shocks. The median time to first appropriate shock was 12 ± 9 months. There were no deaths. In the electrophysiological study, 39% of patients were inducible, but inducibility failed to predict subsequent arrhythmic events. Forty-four percent of patients suffered 21 inappropriate shocks, which were caused by sinus tachycardia, atrial arrhythmias or lead malfunction. Conclusion: Idiopathic ventricular fibrillation patients have a high recurrence rate of potentially fatal ventricular arrhythmias, excluding patients with the Brugada syndrome or other known causes. ICD prevents sudden cardiac death but inappropriate shocks remained a major issue in this young and active population.
- 1 January 2005
- Published by Springer Nature in BMC Medicine
- Vol. 3 (1) , 1
Open AccessRecurrent cardiac events in patients with idiopathic ventricular fibrillation, excluding patients with the Brugada syndrome
Background: The recurrence of cardiac events in patients with idiopathic ventricular fibrillation (VF) excluding patients with the Brugada syndrome is unclear since this entity remains present in previous studies. Methods: Since 1992, 18 patients (72% male) with idiopathic VF out of 455 ICD implants were treated with an implantable cardioverter defibrillator (ICD). The mean age at first ICD implantation was 42 ± 14 years. Brugada syndrome, as well as other primary electrical diseases (e.g. long QT), were systematically excluded in all patients by the absence of the typical electrocardiogram (ST elevation in the right precordial leads) at rest and/or after pharmacological tests (ajmaline, flecainide, or procainamide). Recurrence of cardiac events was prospectively assessed. Results: During a mean follow-up period of 41 ± 27 months, VF recurrence with appropriate shock occurred in 7 patients (39%) covering a total of 27 shocks. The median time to first appropriate shock was 12 ± 9 months. There were no deaths. In the electrophysiological study, 39% of patients were inducible, but inducibility failed to predict subsequent arrhythmic events. Forty-four percent of patients suffered 21 inappropriate shocks, which were caused by sinus tachycardia, atrial arrhythmias or lead malfunction. Conclusion: Idiopathic ventricular fibrillation patients have a high recurrence rate of potentially fatal ventricular arrhythmias, excluding patients with the Brugada syndrome or other known causes. ICD prevents sudden cardiac death but inappropriate shocks remained a major issue in this young and active population.
- 22 July 2002
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 25 (7) , 1131-1134
Permanent Pacemaker Lead Entrapment: Role of the Transesophageal Echocardiography
CHAMPAGNE, J., et al.: Permanent Pacemaker Lead Entrapment: Role of the Transesophageal Echocardiography. Numerous complications induced by pacemaker electrodes have been reported. Although mild tricuspid regurgitation is a well‐documented complication of transvenous right ventricular pacemaker leads secondary to abnormal valve coaptation, severe tricuspid regurgitation resulting from perforation of the tricuspid valve itself is a rare complication. This case report details a patient with severe tricuspid regurgitation secondary to impingement of the tricuspid valve by a permanent pacing lead that was diagnosed by transesophageal echocardiography. Surgical repair was advocated because of symptomatic significant tricuspid regurgitation.
- 22 July 2002
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 25 (7) , 1131-1134
Permanent Pacemaker Lead Entrapment: Role of the Transesophageal Echocardiography
CHAMPAGNE, J., et al.: Permanent Pacemaker Lead Entrapment: Role of the Transesophageal Echocardiography. Numerous complications induced by pacemaker electrodes have been reported. Although mild tricuspid regurgitation is a well‐documented complication of transvenous right ventricular pacemaker leads secondary to abnormal valve coaptation, severe tricuspid regurgitation resulting from perforation of the tricuspid valve itself is a rare complication. This case report details a patient with severe tricuspid regurgitation secondary to impingement of the tricuspid valve by a permanent pacing lead that was diagnosed by transesophageal echocardiography. Surgical repair was advocated because of symptomatic significant tricuspid regurgitation.
- 1 July 2002
- Vol. 18 (7) , 763-7
Differential effect of right and left carotid sinus massage: implications for sudden rate drop pacing algorithm.
This present report describes a patient with syncope in whom asystole was triggered by right carotid sinus massage and complete atrioventricular block with slight bradycardia by left carotid sinus massage. A dual-chamber, rate-responsive, permanent pacemaker with 'sudden rate drop' algorithm was implanted. The present report underlines the pathophysiology and the clinical utility of carotid sinus massage on both sides. Programming considerations to tailor the rate drop algorithm when two different physiological responses are triggered by carotid sinus massage are discussed. The importance of careful clinical assessment to detect all appropriate physiological responses as well as new pacing algorithms is depicted.
- 1 July 2002
- Vol. 18 (7) , 763-7
Differential effect of right and left carotid sinus massage: implications for sudden rate drop pacing algorithm.
This present report describes a patient with syncope in whom asystole was triggered by right carotid sinus massage and complete atrioventricular block with slight bradycardia by left carotid sinus massage. A dual-chamber, rate-responsive, permanent pacemaker with 'sudden rate drop' algorithm was implanted. The present report underlines the pathophysiology and the clinical utility of carotid sinus massage on both sides. Programming considerations to tailor the rate drop algorithm when two different physiological responses are triggered by carotid sinus massage are discussed. The importance of careful clinical assessment to detect all appropriate physiological responses as well as new pacing algorithms is depicted.
- 1 May 2002
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 25 (5) , 863-865
Pacemaker Contact Sensitivity: Case Report and Review of the Literature
DÉRY, J.‐P., et al.: Pacemaker Contact Sensitivity: Case Report and Review of the Literature. Pacemaker contact sensitivity is a rare condition. Less than 25 reports of pacemaker skin reaction have been described over the past 30 years. This report describes one patient who developed contact dermatitis after implantation of two subsequent pacemakers. The diagnosis was made with skin patch tests that were positive to polyurethane 75D and polysulfone beige, two of the pacemaker and connector components. Review of the literature and general guidelines for the management of this unusual condition is depicted in this report.
- 1 May 2002
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 25 (5) , 863-865
Pacemaker Contact Sensitivity: Case Report and Review of the Literature
DÉRY, J.‐P., et al.: Pacemaker Contact Sensitivity: Case Report and Review of the Literature. Pacemaker contact sensitivity is a rare condition. Less than 25 reports of pacemaker skin reaction have been described over the past 30 years. This report describes one patient who developed contact dermatitis after implantation of two subsequent pacemakers. The diagnosis was made with skin patch tests that were positive to polyurethane 75D and polysulfone beige, two of the pacemaker and connector components. Review of the literature and general guidelines for the management of this unusual condition is depicted in this report.