S. C. Kaushik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S. C. Kaushik has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Ranjana Hans
Centre for Energy Studies, Indian Institute of Technology Delhi, New Delhi, India
2 shared publications- Sundararaj Manikandan
Department of Mechanical Engineering, Faculty of Engineering and Technology, SRM Institute of Science and Technology
2 shared publications - Abdus Salam Azad
GreenTree Building Energy Pvt. Ltd., Noida 201301, India
1 shared publication Akhilesh Arora
Delhi Technological University
1 shared publication- Akhilesh Arora
Department of Mechanical Engineering, Delhi College of Engineering, New Delhi 110042, India
1 shared publication - Dibakar Rakshit
Department of Energy Science and Engineering, Indian Institute of Technology Delhi, New Delhi, India
1 shared publication
Latest Publications
- 17 May 2022
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 144 (5) , 1-30
Energy Savings of an Optimized Daylight-Pipe System With Single and Dual Reflectors in Tropical Climates of India
Buildings in India consume over one-third of the country’s total electricity consumption and out of which about 28% and 25% are accounted for lighting energy in the residential and commercial buildings, respectively. Passive daylighting system using tubular daylight-pipe is a promising technique to save lighting energy by illuminating deep building interiors that have no daylight access through exterior windows. In this study, an innovative daylight-pipe has been designed and developed for enhanced daylighting performance by optimizing configurations of single and dual reflectors at its receiver. A detailed daylight assessment has been carried out using controlled experimentation while varying the reflectors position and orientation inside the hemispherical receiver of the daylight-pipe. It has been found that the single reflector oriented toward south has the best performance with a light transmission efficiency of 35.6%. Furthermore, monthly electrical energy savings due to the advanced daylight-pipe along with various supplementary electrical lighting options such as incandescent bulb, compact fluorescent lamp (CFL), and light emitting diode (LED) were estimated and compared for various climatic locations of India. From these evaluations, a lighting energy saving up to 23% has been observed in the summer month of May for temperate climate of Pune and hot-dry climate of Jodhpur.
- 17 May 2022
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 144 (5) , 1-30
Energy Savings of an Optimized Daylight-Pipe System With Single and Dual Reflectors in Tropical Climates of India
Buildings in India consume over one-third of the country’s total electricity consumption and out of which about 28% and 25% are accounted for lighting energy in the residential and commercial buildings, respectively. Passive daylighting system using tubular daylight-pipe is a promising technique to save lighting energy by illuminating deep building interiors that have no daylight access through exterior windows. In this study, an innovative daylight-pipe has been designed and developed for enhanced daylighting performance by optimizing configurations of single and dual reflectors at its receiver. A detailed daylight assessment has been carried out using controlled experimentation while varying the reflectors position and orientation inside the hemispherical receiver of the daylight-pipe. It has been found that the single reflector oriented toward south has the best performance with a light transmission efficiency of 35.6%. Furthermore, monthly electrical energy savings due to the advanced daylight-pipe along with various supplementary electrical lighting options such as incandescent bulb, compact fluorescent lamp (CFL), and light emitting diode (LED) were estimated and compared for various climatic locations of India. From these evaluations, a lighting energy saving up to 23% has been observed in the summer month of May for temperate climate of Pune and hot-dry climate of Jodhpur.
- 22 December 2020
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 143 (9) , 1-18
Effect of Hydrogen Enrichment Strategy on Performance and Emission Features of Biodiesel-Biogas Dual Fuel Engine Using Simulation and Experimental Analyses
In the present work, hydrogen enrichment in biogas is studied as a potential approach to improve the performance and emission features of a biodiesel-biogas dual fuel engine. A single-cylinder diesel engine is modified to operate in dual fuel mode using Jatropha curcas biodiesel as the pilot fuel and biogas as the main fuel. An electronic control unit is developed in-house to study 5−20% hydrogen enrichment in biogas using the timed manifold injection (TMI) technique. A three-dimensional computational fluid dynamics-based simulation methodology is presented for optimal selection of TMI parameters to ensure efficient and safe operation of the engine. Subsequently, the optimized injection conditions are used for the experimental evaluations, which are performed for performance and emission characteristics of the engine at low and high engine loads. Engine performance is analyzed based on energy and exergy analyses, whereas hydrocarbon (HC), carbon monoxide (CO), oxides of nitrogen (NOx), and smoke emissions are analyzed for emission characterization. The simulation results show that the injection angle and injection pressure influence in-cylinder mixture formation and hydrogen accumulation in the intake manifold. A combination of injection angle = 60 deg and injection pressure = 150 kPa offers good mixture formation. Experimental results show that at 20% hydrogen enrichment, exergy efficiencies of the dual fuel engine are increased from 8.4% to 10.1% at low load and 23.3% to 25.5% at high load. However, maximum reductions in HC and CO emissions of 35.6% and 50.0%, respectively, are calculated at low load.
- 22 December 2020
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 143 (9) , 1-18
Effect of Hydrogen Enrichment Strategy on Performance and Emission Features of Biodiesel-Biogas Dual Fuel Engine Using Simulation and Experimental Analyses
In the present work, hydrogen enrichment in biogas is studied as a potential approach to improve the performance and emission features of a biodiesel-biogas dual fuel engine. A single-cylinder diesel engine is modified to operate in dual fuel mode using Jatropha curcas biodiesel as the pilot fuel and biogas as the main fuel. An electronic control unit is developed in-house to study 5−20% hydrogen enrichment in biogas using the timed manifold injection (TMI) technique. A three-dimensional computational fluid dynamics-based simulation methodology is presented for optimal selection of TMI parameters to ensure efficient and safe operation of the engine. Subsequently, the optimized injection conditions are used for the experimental evaluations, which are performed for performance and emission characteristics of the engine at low and high engine loads. Engine performance is analyzed based on energy and exergy analyses, whereas hydrocarbon (HC), carbon monoxide (CO), oxides of nitrogen (NOx), and smoke emissions are analyzed for emission characterization. The simulation results show that the injection angle and injection pressure influence in-cylinder mixture formation and hydrogen accumulation in the intake manifold. A combination of injection angle = 60 deg and injection pressure = 150 kPa offers good mixture formation. Experimental results show that at 20% hydrogen enrichment, exergy efficiencies of the dual fuel engine are increased from 8.4% to 10.1% at low load and 23.3% to 25.5% at high load. However, maximum reductions in HC and CO emissions of 35.6% and 50.0%, respectively, are calculated at low load.
- 6 September 2019
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 142 (1) , 1-38
Suitability Assessment and Experimental Characterization of Phase Change Materials for Energy Conservation in Indian Buildings
With increasing energy consumption in buildings, energy efficiency measures are matter of prime concern. A huge portion of energy consumed in buildings is used for regulating the thermal comfort. A solution to this is to incorporate phase change material (PCM) within the building elements which increases their overall thermal capacity. In the present study, the temperature of inner room surface, with and without PCM incorporation, is calculated for composite climate of Delhi. The analysis of PCM sandwiched walls has been performed. The performance analysis of five PCMs, having different melting temperatures, is carried out with nodal temperatures as the output. The results show that a phase change temperature range of 34–38 °C is suitable for peak summer conditions of Delhi. It is also observed that due to the low thermal conductivity of PCMs, they act as both storage medium and insulation, thus reducing temperature fluctuation during summer/winter. Based on the simulation, three PCMs were found suitable and hence were experimentally tested for their characteristic charging and discharging properties and performance, using differential scanning calorimeter (DSC). Based on the characterization results, it is concluded that two commercially available PCMs (Eicosane and OM35) are suitable for Delhi. All the other PCMs have also been simulated for different climatic conditions in India and their impact on heat gain has been assessed.
- 6 September 2019
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 142 (1) , 1-38
Suitability Assessment and Experimental Characterization of Phase Change Materials for Energy Conservation in Indian Buildings
With increasing energy consumption in buildings, energy efficiency measures are matter of prime concern. A huge portion of energy consumed in buildings is used for regulating the thermal comfort. A solution to this is to incorporate phase change material (PCM) within the building elements which increases their overall thermal capacity. In the present study, the temperature of inner room surface, with and without PCM incorporation, is calculated for composite climate of Delhi. The analysis of PCM sandwiched walls has been performed. The performance analysis of five PCMs, having different melting temperatures, is carried out with nodal temperatures as the output. The results show that a phase change temperature range of 34–38 °C is suitable for peak summer conditions of Delhi. It is also observed that due to the low thermal conductivity of PCMs, they act as both storage medium and insulation, thus reducing temperature fluctuation during summer/winter. Based on the simulation, three PCMs were found suitable and hence were experimentally tested for their characteristic charging and discharging properties and performance, using differential scanning calorimeter (DSC). Based on the characterization results, it is concluded that two commercially available PCMs (Eicosane and OM35) are suitable for Delhi. All the other PCMs have also been simulated for different climatic conditions in India and their impact on heat gain has been assessed.
- 31 July 2018
- Published by Springer Nature
- p. 525-543
Parametric Optimization of Concentrated Photovoltaic-Thermoelectric Hybrid System
- 31 July 2018
- Published by Springer Nature
- p. 525-543
Parametric Optimization of Concentrated Photovoltaic-Thermoelectric Hybrid System
- 18 June 2018
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 140 (5)
Performance Prediction and Assessment of Energy Conservation Potential for a Light Pipe System in Indian Composite Climate of New Delhi
Light pipes are popularly used for transporting outdoor sunlight into deep spaces of the building, and hence, use of artificial lighting could be substantially reduced. Performance prediction of a light pipe is an essential step before its use in buildings, so that energy saving potential of the light pipe could be quantified. This paper deals with experimental validation of three existing semi-empirical models for light pipes with different aspect ratios, installed on a windowless test room, at IIT Delhi, New Delhi. Two new semi-empirical models based on the existing correlations are developed. The new model found to perform better with mean bias error (MBE) and root-mean-squared error (MSE) of 0.076 and 0.01, respectively. The better performing new model is used for the evaluation of hourly internal illuminance by the light pipe in a typical meteorological year (TMY) in New Delhi. From hourly internal illuminance in a typical meteorological year, the energy saving potential and CO2 mitigation potential of light pipe system for the test room are evaluated. Monthly average energy saving potentials of the light pipe-fluorescent tube light system are found to be 50% for continuous dimming control and 38% for three-step on–off control. Results show that the light pipe-fluorescent tube light system, with different lighting controls, could reduce CO2 emissions to 15–50%.
- 18 June 2018
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 140 (5)
Performance Prediction and Assessment of Energy Conservation Potential for a Light Pipe System in Indian Composite Climate of New Delhi
Light pipes are popularly used for transporting outdoor sunlight into deep spaces of the building, and hence, use of artificial lighting could be substantially reduced. Performance prediction of a light pipe is an essential step before its use in buildings, so that energy saving potential of the light pipe could be quantified. This paper deals with experimental validation of three existing semi-empirical models for light pipes with different aspect ratios, installed on a windowless test room, at IIT Delhi, New Delhi. Two new semi-empirical models based on the existing correlations are developed. The new model found to perform better with mean bias error (MBE) and root-mean-squared error (MSE) of 0.076 and 0.01, respectively. The better performing new model is used for the evaluation of hourly internal illuminance by the light pipe in a typical meteorological year (TMY) in New Delhi. From hourly internal illuminance in a typical meteorological year, the energy saving potential and CO2 mitigation potential of light pipe system for the test room are evaluated. Monthly average energy saving potentials of the light pipe-fluorescent tube light system are found to be 50% for continuous dimming control and 38% for three-step on–off control. Results show that the light pipe-fluorescent tube light system, with different lighting controls, could reduce CO2 emissions to 15–50%.
- 1 May 2017
- Published by EJournal Publishing in Journal of Clean Energy Technologies
- Vol. 5 (3) , 222-227
Energy and Exergy Analysis of Solar Triple Effect Refrigeration Cycle
- 1 May 2017
- Published by EJournal Publishing in Journal of Clean Energy Technologies
- Vol. 5 (3) , 222-227
Energy and Exergy Analysis of Solar Triple Effect Refrigeration Cycle
- 13 April 2016
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 45 (7) , 3400-3409
Energy and Exergy Analysis of an Annular Thermoelectric Heat Pump
- 13 April 2016
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 45 (7) , 3400-3409
Energy and Exergy Analysis of an Annular Thermoelectric Heat Pump
- Open Access
- 1 January 2016
- Published by EJournal Publishing in International Journal of Environmental Science and Development
- Vol. 7 (8) , 615-620
Theoretical and Experimental Investigations on Solar Photovoltaic Driven Thermoelectric Cooler System for Cold Storage Application
- 1 January 2016
- Published by EJournal Publishing in International Journal of Environmental Science and Development
- Vol. 7 (8) , 615-620
Open AccessTheoretical and Experimental Investigations on Solar Photovoltaic Driven Thermoelectric Cooler System for Cold Storage Application