Daniel F. Huber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniel F. Huber has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Boris Kaminsky
Carnegie Mellon Univ. (United States)
1 shared publication- C. Kent Kwoh
University of Pittsburgh and Pittsburgh VA Healthcare System, Pittsburgh, PA, USA
1 shared publication - Joseph Enama
Department of Medicine, University of Pittsburgh School of Medicine, 3550 Terrace Street, Pittsburgh, PA 15213, USA
1 shared publication - Julie Lunich
Division of Rheumatology, Children's Hospital of Pittsburgh, 3705 Fifth Avenue, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA
1 shared publication Louis J. Denes
Carnegie Mellon Univ. (United States)
1 shared publication- Louis J. Denes
Robotics Institute, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213, USA
1 shared publication
Latest Publications
- Open Access
- 23 January 2008
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 10 (1) , R10
Three-dimensional and thermal surface imaging produces reliable measures of joint shape and temperature: a potential tool for quantifying arthritis
Introduction: The assessment of joints with active arthritis is a core component of widely used outcome measures. However, substantial variability exists within and across examiners in assessment of these active joint counts. Swelling and temperature changes, two qualities estimated during active joint counts, are amenable to quantification using noncontact digital imaging technologies. We sought to explore the ability of three dimensional (3D) and thermal imaging to reliably measure joint shape and temperature. Methods: A Minolta 910 Vivid non-contact 3D laser scanner and a Meditherm med2000 Pro Infrared camera were used to create digital representations of wrist and metacarpalphalangeal (MCP) joints. Specialized software generated 3 quantitative measures for each joint region: 1) Volume; 2) Surface Distribution Index (SDI), a marker of joint shape representing the standard deviation of vertical distances from points on the skin surface to a fixed reference plane; 3) Heat Distribution Index (HDI), representing the standard error of temperatures. Seven wrists and 6 MCP regions from 5 subjects with arthritis were used to develop and validate 3D image acquisition and processing techniques. HDI values from 18 wrist and 9 MCP regions were obtained from 17 patients with active arthritis and compared to data from 10 wrist and MCP regions from 5 controls. Standard deviation (SD), coefficient of variation (CV), and intraclass correlation coefficients (ICC) were calculated for each quantitative measure to establish their reliability. CVs for volume and SDI were <1.3% and ICCs were greater than 0.99. Results: Thermal measures were less reliable than 3D measures. However, significant differences were observed between control and arthritis HDI values. Two case studies of arthritic joints demonstrated quantifiable changes in swelling and temperature corresponding with changes in symptoms and physical exam findings. Conclusion: 3D and thermal imaging provide reliable measures of joint volume, shape, and thermal patterns. Further refinement may lead to the use of these technologies to improve the assessment of disease activity in arthritis.
- 23 January 2008
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 10 (1) , R10
Open AccessThree-dimensional and thermal surface imaging produces reliable measures of joint shape and temperature: a potential tool for quantifying arthritis
Introduction: The assessment of joints with active arthritis is a core component of widely used outcome measures. However, substantial variability exists within and across examiners in assessment of these active joint counts. Swelling and temperature changes, two qualities estimated during active joint counts, are amenable to quantification using noncontact digital imaging technologies. We sought to explore the ability of three dimensional (3D) and thermal imaging to reliably measure joint shape and temperature. Methods: A Minolta 910 Vivid non-contact 3D laser scanner and a Meditherm med2000 Pro Infrared camera were used to create digital representations of wrist and metacarpalphalangeal (MCP) joints. Specialized software generated 3 quantitative measures for each joint region: 1) Volume; 2) Surface Distribution Index (SDI), a marker of joint shape representing the standard deviation of vertical distances from points on the skin surface to a fixed reference plane; 3) Heat Distribution Index (HDI), representing the standard error of temperatures. Seven wrists and 6 MCP regions from 5 subjects with arthritis were used to develop and validate 3D image acquisition and processing techniques. HDI values from 18 wrist and 9 MCP regions were obtained from 17 patients with active arthritis and compared to data from 10 wrist and MCP regions from 5 controls. Standard deviation (SD), coefficient of variation (CV), and intraclass correlation coefficients (ICC) were calculated for each quantitative measure to establish their reliability. CVs for volume and SDI were <1.3% and ICCs were greater than 0.99. Results: Thermal measures were less reliable than 3D measures. However, significant differences were observed between control and arthritis HDI values. Two case studies of arthritic joints demonstrated quantifiable changes in swelling and temperature corresponding with changes in symptoms and physical exam findings. Conclusion: 3D and thermal imaging provide reliable measures of joint volume, shape, and thermal patterns. Further refinement may lead to the use of these technologies to improve the assessment of disease activity in arthritis.
- 27 January 1998
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3207, 94-103
Spectro-polarimetric imager for intelligent transportation systems
We have built a portable spectro-polarimetric machine vision system that operates at video frame rates. Our system contains only electronically controllable components, including an imaging acousto-optic tunable filter (AOTF), a phase retarder, acceptance and imaging optics, and a standard CCD-based camera. The device operates like an ordinary camera, except that a computer controls the spectral and polarization content of light to be viewed. For example, by sweeping the wavelength over the AOTF's range, one can obtain a spectral signature for each pixel in an image. Alternately, the camera can switch between two wavelengths, allowing for high-speed discrimination of closely matched colors in a scene. In addition to digitally controlling the wavelength, our imager uses a liquid crystal retarder to filter images based on polarization signatures of objects. We have implemented a number of algorithms to take advantage of the unique capabilities of our sensor, some of which can be applied to problems specific to transportation systems. We present two image processing applications that highlight the different methods we use to analyze scenes with our system. One application uses spectral processing to locate vegetation in a scene; the second uses polarization signatures to detect glare from hazardous road conditions such as water and ice.
- 27 January 1998
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3207, 94-103
Spectro-polarimetric imager for intelligent transportation systems
We have built a portable spectro-polarimetric machine vision system that operates at video frame rates. Our system contains only electronically controllable components, including an imaging acousto-optic tunable filter (AOTF), a phase retarder, acceptance and imaging optics, and a standard CCD-based camera. The device operates like an ordinary camera, except that a computer controls the spectral and polarization content of light to be viewed. For example, by sweeping the wavelength over the AOTF's range, one can obtain a spectral signature for each pixel in an image. Alternately, the camera can switch between two wavelengths, allowing for high-speed discrimination of closely matched colors in a scene. In addition to digitally controlling the wavelength, our imager uses a liquid crystal retarder to filter images based on polarization signatures of objects. We have implemented a number of algorithms to take advantage of the unique capabilities of our sensor, some of which can be applied to problems specific to transportation systems. We present two image processing applications that highlight the different methods we use to analyze scenes with our system. One application uses spectral processing to locate vegetation in a scene; the second uses polarization signatures to detect glare from hazardous road conditions such as water and ice.