Chiang-Ho Cheng
Research Subjects
Chiang-Ho Cheng has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Chih-Jer Lin
Graduate Institute of Automation Technology, National Taipei University of Technology, Taipei 10608, Taiwan
2 shared publications An-Shik Yang
National Taipei University of Technology
1 shared publication- An-Shik Yang
Department of Energy and Refrigerating Air-conditioning Engineering, National Taipei University of Technology, Taipei 106, Taiwan
1 shared publication - Chi-Ming Huang
Industrial Technology Research Institute, Opto-Electronics& Systems Laboratories
1 shared publication - Chia-Yen Lee
National Pingtung University of Science and Technology
1 shared publication - Chien-Chung Fu
National Tsing-Hua University
1 shared publication
Latest Publications
- Open Access
- 2 February 2016
- Published by MDPI AG in Applied Sciences
- Vol. 6 (2) , 42
Design of an Image-Servo Mask Alignment System Using Dual CCDs with an XXY Stage
Mask alignment of photolithography technology is used in many applications, such as micro electro mechanical systems’ semiconductor process, printed circuits board, and flat panel display. As the dimensions of the product are getting smaller and smaller, the automatic mask alignment of photolithography is becoming more and more important. The traditional stacked XY-Θz stage is heavy and it has cumulative flatness errors due to its stacked assembly mechanism. The XXY stage has smaller cumulative error due to its coplanar design and it can move faster than the traditional XY-Θz stage. However, the relationship between the XXY stage’s movement and the commands of the three motors is difficult to compute, because the movements of the three motors on the same plane are coupling. Therefore, an artificial neural network is studied to establish a nonlinear mapping from the desired position and orientation of the stage to three motors’ commands. Further, this paper proposes an image-servo automatic mask alignment system, which consists of a coplanar XXY stage, dual GIGA-E CCDs with lens and a programmable automatic controller (PAC). Before preforming the compensation, a self-developed visual-servo provides the positioning information which is obtained from the image processing and pattern recognition according to the specified fiducial marks. To obtain better precision, two methods including the center of gravity method and the generalize Hough Transformation are studied to correct the shift positioning error.
- 2 February 2016
- Published by MDPI AG in Applied Sciences
- Vol. 6 (2) , 42
Open AccessDesign of an Image-Servo Mask Alignment System Using Dual CCDs with an XXY Stage
Mask alignment of photolithography technology is used in many applications, such as micro electro mechanical systems’ semiconductor process, printed circuits board, and flat panel display. As the dimensions of the product are getting smaller and smaller, the automatic mask alignment of photolithography is becoming more and more important. The traditional stacked XY-Θz stage is heavy and it has cumulative flatness errors due to its stacked assembly mechanism. The XXY stage has smaller cumulative error due to its coplanar design and it can move faster than the traditional XY-Θz stage. However, the relationship between the XXY stage’s movement and the commands of the three motors is difficult to compute, because the movements of the three motors on the same plane are coupling. Therefore, an artificial neural network is studied to establish a nonlinear mapping from the desired position and orientation of the stage to three motors’ commands. Further, this paper proposes an image-servo automatic mask alignment system, which consists of a coplanar XXY stage, dual GIGA-E CCDs with lens and a programmable automatic controller (PAC). Before preforming the compensation, a self-developed visual-servo provides the positioning information which is obtained from the image processing and pattern recognition according to the specified fiducial marks. To obtain better precision, two methods including the center of gravity method and the generalize Hough Transformation are studied to correct the shift positioning error.
- 30 December 2015
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (6) , 1709-1717
Characteristic studies of a novel piezoelectric impedance micropump
- 30 December 2015
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (6) , 1709-1717
Characteristic studies of a novel piezoelectric impedance micropump
- 27 April 2014
- Published by Springer Nature
- p. 101-115
Performance Evaluation of the Valveless Micropump with Piezoelectric Actuator
- 27 April 2014
- Published by Springer Nature
- p. 101-115
Performance Evaluation of the Valveless Micropump with Piezoelectric Actuator
- 19 June 2013
- Published by Springer Nature in Microsystem Technologies
- Vol. 19 (11) , 1707-1715
Characteristic studies of the piezoelectrically actuated micropump with check valve
- 19 June 2013
- Published by Springer Nature in Microsystem Technologies
- Vol. 19 (11) , 1707-1715
Characteristic studies of the piezoelectrically actuated micropump with check valve
- 26 November 2008
- Published by Springer Nature in Microsystem Technologies
- Vol. 15 (8) , 1171-1177
Design and fabrication of novel micro electromagnetic actuator
- 26 November 2008
- Published by Springer Nature in Microsystem Technologies
- Vol. 15 (8) , 1171-1177
Design and fabrication of novel micro electromagnetic actuator
- 26 May 2008
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 201 (1-3) , 683-688
Processing of PZT actuator and nickel plate in a multi-droplets microejector
- 26 May 2008
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 201 (1-3) , 683-688
Processing of PZT actuator and nickel plate in a multi-droplets microejector
- 15 January 2008
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 141 (1) , 160-165
Fabrication of a novel piezoelectric actuator with high load-bearing capability
- 15 January 2008
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 141 (1) , 160-165
Fabrication of a novel piezoelectric actuator with high load-bearing capability
- 14 February 2006
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 126 (2) , 386-395
Effect of poling conditions on out-of-plane displacement for a shear mode PZT actuator
- 14 February 2006
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 126 (2) , 386-395
Effect of poling conditions on out-of-plane displacement for a shear mode PZT actuator
- 1 January 2005
- Published by Springer Nature in MRS Proceedings
- Vol. 888
Active CPU Cooling System with Piezoelectric Actuated Droplet Generator
- 1 January 2005
- Published by Springer Nature in MRS Proceedings
- Vol. 888
Active CPU Cooling System with Piezoelectric Actuated Droplet Generator