Rafael Nilson Rodrigues
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rafael Nilson Rodrigues has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Juliano Kasmirski Zatta
Smart Grids Laboratory - Labsmart, Federal Institute of Santa Catarina, Florianópolis, Brazil
3 shared publicationsL. S. B. Pereira
Federal Institute of Santa Catarina,undergraduate electronics engineering at Electronics Department,Florianpolis,SC,Brasil,88020-300
3 shared publications- Alexandre Rasi Aoki
Department of Electrical Engineering, Federal University of Parana, Curitiba 81531-990, PR, Brazil
2 shared publications Edson L. da Silva
2 shared publicationsErlon C. Finardi
2 shared publicationsG. A. Massuyama
Federal Institute of Santa Catarina, Florianópolis, SC,undergraduate electronics engineering at Electronics Department,Brasil,88020-300
2 shared publications
Latest Publications
- Open Access
Electrical Event Detection and Monitoring Data Storage from Wide Area Measurement System
Synchronized phasor measurement systems are being widely used around the world and have become essential elements in the evolution of the operation of large electrical power systems (EPS). These systems, called Phasor Measurement Units (PMUs), are capable of recording and communicating dynamic data from the EPSs in a synchronized way by GPS and with a high sampling rate, generate a huge set of data that, among many applications, has the capacity to detect events. In this way, this work presents a data management system architecture applied to a real PMU system located in the state of Paraná, Brazil that detects and storages events using principal component analysis and Pearson correlation. This method can detect and store electrical events that occurred during the operation of the national interconnected system of Brazil with good results.
Open AccessElectrical Event Detection and Monitoring Data Storage from Wide Area Measurement System
Synchronized phasor measurement systems are being widely used around the world and have become essential elements in the evolution of the operation of large electrical power systems (EPS). These systems, called Phasor Measurement Units (PMUs), are capable of recording and communicating dynamic data from the EPSs in a synchronized way by GPS and with a high sampling rate, generate a huge set of data that, among many applications, has the capacity to detect events. In this way, this work presents a data management system architecture applied to a real PMU system located in the state of Paraná, Brazil that detects and storages events using principal component analysis and Pearson correlation. This method can detect and store electrical events that occurred during the operation of the national interconnected system of Brazil with good results.
- 17 August 2021
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 32 (6) , 1617-1626
Artificial Neural Network Approach for Fault Detection and Identification in Power Systems with Wide Area Measurement Systems
- 17 August 2021
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 32 (6) , 1617-1626
Artificial Neural Network Approach for Fault Detection and Identification in Power Systems with Wide Area Measurement Systems
- Open Access
A Hybrid VLC-RF Portable Phasor Measurement Unit for Deep Tunnels
In this manuscript we propose a hybrid Visible Light Communication and Radio Frequency (VLC-RF) scheme for the implementation of a portable Phaser Measurement Unit (PMU) for deep underground tunnels. Through computer simulations and laboratory measurements we are capable of providing Coordinated Universal Time (UTC) to the PMUs, as well as high accuracy positioning in a Global Positioning System (GPS) denied environment. The estimated PMU position, time stamp, and electrical power system measurements are sent to a central monitoring station using a radio frequency uplink with a data rate of hundreds of Kbps. Simulations and experimental measurements show that the proposed scheme can be used to control a large number of VLC-RF PMU devices inside a tunnel. The tests demonstrate the viability of the hybrid prototype, which will improve performance compared to commercial PMUs that lack these features.
Open AccessA Hybrid VLC-RF Portable Phasor Measurement Unit for Deep Tunnels
In this manuscript we propose a hybrid Visible Light Communication and Radio Frequency (VLC-RF) scheme for the implementation of a portable Phaser Measurement Unit (PMU) for deep underground tunnels. Through computer simulations and laboratory measurements we are capable of providing Coordinated Universal Time (UTC) to the PMUs, as well as high accuracy positioning in a Global Positioning System (GPS) denied environment. The estimated PMU position, time stamp, and electrical power system measurements are sent to a central monitoring station using a radio frequency uplink with a data rate of hundreds of Kbps. Simulations and experimental measurements show that the proposed scheme can be used to control a large number of VLC-RF PMU devices inside a tunnel. The tests demonstrate the viability of the hybrid prototype, which will improve performance compared to commercial PMUs that lack these features.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Development of a phasor measurement unit prototype applied to Brazilian and Chilean electrical systems
A reliable and efficient electric distribution network depends on a real-time acquisition system and data transmission. Monitoring the dynamic performance of large areas of the transmission systems is based on Phasor Measurement Units (PMUs). The advantage of using PMUs is a high data acquisition rate and the synchronization of measurements using Global Positioning System (GPS). This paper presents the development of a low-cost PMU prototype, based on IEEE C37.118 standards, using Digital Signal Processor (DSP).
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Development of a phasor measurement unit prototype applied to Brazilian and Chilean electrical systems
A reliable and efficient electric distribution network depends on a real-time acquisition system and data transmission. Monitoring the dynamic performance of large areas of the transmission systems is based on Phasor Measurement Units (PMUs). The advantage of using PMUs is a high data acquisition rate and the synchronization of measurements using Global Positioning System (GPS). This paper presents the development of a low-cost PMU prototype, based on IEEE C37.118 standards, using Digital Signal Processor (DSP).
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Energy management web portal prototype (PGEN) for public institutions
Over the years, the demand for electricity in Brazil has steadily risen and the energy taxes have suffered several adjustments, increasing the megawatt per hour value. These adjustments combined with seasons that may have less generation of electric energy can make electricity a monetary concern, especially for industrial customers. With the increase of price in electricity bills, the management of energy is a fundamental tool to achieve energy efficiency and reduce costs while maintaining the same production rate. In Brazil the energy efficiency policy is rarely adopted, not having a significant amount of systems that can provide such service effectively and at a low cost. This paper proposes the development of a low-cost prototype for monitoring the consumption of electricity in real-time using communication with electronic meters of power distribution companies (ISO 50001) and a web platform that can process and display the data. Making a comparative analysis with the daily collected data from the prototype, it's possible to find patterns of power consumption, high demand moments and abnormal use of energy. The prototype was able to provide important data that can be used to make rational choices regarding on how to optimize the consumption of energy and achieve energy efficiency, making it a cheap and reliable energy management system.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Energy management web portal prototype (PGEN) for public institutions
Over the years, the demand for electricity in Brazil has steadily risen and the energy taxes have suffered several adjustments, increasing the megawatt per hour value. These adjustments combined with seasons that may have less generation of electric energy can make electricity a monetary concern, especially for industrial customers. With the increase of price in electricity bills, the management of energy is a fundamental tool to achieve energy efficiency and reduce costs while maintaining the same production rate. In Brazil the energy efficiency policy is rarely adopted, not having a significant amount of systems that can provide such service effectively and at a low cost. This paper proposes the development of a low-cost prototype for monitoring the consumption of electricity in real-time using communication with electronic meters of power distribution companies (ISO 50001) and a web platform that can process and display the data. Making a comparative analysis with the daily collected data from the prototype, it's possible to find patterns of power consumption, high demand moments and abnormal use of energy. The prototype was able to provide important data that can be used to make rational choices regarding on how to optimize the consumption of energy and achieve energy efficiency, making it a cheap and reliable energy management system.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Machine Learning Applied to Energy Efficiency of Large Consumers
The use of electric energy is rapidly increasing, so it is essential that users improve their understanding of electric consumption, thus reducing waste and improper use. The present work uses Machine Learning techniques (specifically Linear Regression and Random Forest) to model the relationship between electricity consumption and climatic conditions within the Federal Institute of Education, Science and Technology of Santa Catarina (IFSC) and the Ministries Esplanade (headquarters of the Brazilian Executive, in Brasilia). Historical data of active power, ambient temperature and atmospheric pressure obtained from the database of the project PGEN. The results show that the model allows predicting the instantaneous energy consumption of the localities with an average error of 22.75% KW. The building of the Ministries Esplanade obtained the lower errors, and the campus Florianópolis obtained the bigger erros.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Machine Learning Applied to Energy Efficiency of Large Consumers
The use of electric energy is rapidly increasing, so it is essential that users improve their understanding of electric consumption, thus reducing waste and improper use. The present work uses Machine Learning techniques (specifically Linear Regression and Random Forest) to model the relationship between electricity consumption and climatic conditions within the Federal Institute of Education, Science and Technology of Santa Catarina (IFSC) and the Ministries Esplanade (headquarters of the Brazilian Executive, in Brasilia). Historical data of active power, ambient temperature and atmospheric pressure obtained from the database of the project PGEN. The results show that the model allows predicting the instantaneous energy consumption of the localities with an average error of 22.75% KW. The building of the Ministries Esplanade obtained the lower errors, and the campus Florianópolis obtained the bigger erros.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Phasor Measurement Unit based on discrete fourier transform using digital signal processor
A reliable and efficient electric distribution network depends on a real-time acquisition system and data transmission. Monitoring the dynamic performance of large areas of the transmission systems is based on Phasor Measurement Units (PMUs). The advantage of using PMUs is a high data acquisition rate and the synchronization of measurements using Global Positioning System (GPS). This paper presents the development of a low-cost PMU prototype, based on IEEE C37.118 standards, using Digital Signal Processor (DSP).
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Phasor Measurement Unit based on discrete fourier transform using digital signal processor
A reliable and efficient electric distribution network depends on a real-time acquisition system and data transmission. Monitoring the dynamic performance of large areas of the transmission systems is based on Phasor Measurement Units (PMUs). The advantage of using PMUs is a high data acquisition rate and the synchronization of measurements using Global Positioning System (GPS). This paper presents the development of a low-cost PMU prototype, based on IEEE C37.118 standards, using Digital Signal Processor (DSP).
- 10 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sistema de supervisão de consumo de energia elétrica baseado em plataforma web
The energy consumption had grown deeply in the entire world. In Brazil, although the economic growth in the last years had been underwhelming, the energy consumption rate continues high. Recently, at the beginning of the year 2015, meaningful adjusts had been done at the energy tax. Especially on the state of Santa Catarina, the National Agency of Electrical Energy of Brazil (ANEEL) approved a readjustment of 43% on the bills of the industrial customer of electricity. The concepts and advantages of Smart Grids make relevant detailed measurements. These aspects combined with the recent adjustments on the electricity bills fall under the need to develop real-time consumption monitoring systems. From this point of view, there is not a significant amount of systems designed to achieve those functions simply and at low cost. This paper proposes the development of a low-cost prototype for monitoring the consumption of electricity in real-time using communication with electronic meters of power distribution companies. Specifically, we seek to develop a prototype computer based on the Intel® Galileo Gen2 platform and data communication standard ABNT NBR 14522.
- 10 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sistema de supervisão de consumo de energia elétrica baseado em plataforma web
The energy consumption had grown deeply in the entire world. In Brazil, although the economic growth in the last years had been underwhelming, the energy consumption rate continues high. Recently, at the beginning of the year 2015, meaningful adjusts had been done at the energy tax. Especially on the state of Santa Catarina, the National Agency of Electrical Energy of Brazil (ANEEL) approved a readjustment of 43% on the bills of the industrial customer of electricity. The concepts and advantages of Smart Grids make relevant detailed measurements. These aspects combined with the recent adjustments on the electricity bills fall under the need to develop real-time consumption monitoring systems. From this point of view, there is not a significant amount of systems designed to achieve those functions simply and at low cost. This paper proposes the development of a low-cost prototype for monitoring the consumption of electricity in real-time using communication with electronic meters of power distribution companies. Specifically, we seek to develop a prototype computer based on the Intel® Galileo Gen2 platform and data communication standard ABNT NBR 14522.
- 10 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A low cost prototype of a Phasor Measurement Unit using Digital Signal Processor
A network of reliable and efficient electricity depends on an acquisition system and data transmission in real time. Monitoring the dynamic performance of large areas of the transmission systems is based on Phasor Measurement Units (PMUs). The advantage of using PMUs is on a high rate of acquisition and synchronization measurements using Global Positioning System (GPS). This paper presents the development of a low cost PMU prototype, based on IEEE C37.118 standards using Digital Signal Processor (DSP).
- 10 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A low cost prototype of a Phasor Measurement Unit using Digital Signal Processor
A network of reliable and efficient electricity depends on an acquisition system and data transmission in real time. Monitoring the dynamic performance of large areas of the transmission systems is based on Phasor Measurement Units (PMUs). The advantage of using PMUs is on a high rate of acquisition and synchronization measurements using Global Positioning System (GPS). This paper presents the development of a low cost PMU prototype, based on IEEE C37.118 standards using Digital Signal Processor (DSP).
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Facing the data analysis complexity for the energetic efficiency management at great copper mining, in Codelco Chuquicamata, Chile
This study is centered in the complexity of the data analysis for the management of the energetic efficiency in the productive processes of copper. For that the study is divided in two stages, in the first one, through a process of hierarchical analysis (AHP), it is stablished the importance of the characteristics to be considered for the gathering of information related to the energetic efficiency. In the second stage, it is analyzed how the energetic consumption results a critical variable in copper production, being the unitarian operation of the concentrator, the one of the most energetic consumption, together with its most important actives, the SAG and Ball mills. Consequently, the study standardized a model to obtain data in the concentrator, thus evaluate the different areas of the organization, according to the characteristics or qualities of the information.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Facing the data analysis complexity for the energetic efficiency management at great copper mining, in Codelco Chuquicamata, Chile
This study is centered in the complexity of the data analysis for the management of the energetic efficiency in the productive processes of copper. For that the study is divided in two stages, in the first one, through a process of hierarchical analysis (AHP), it is stablished the importance of the characteristics to be considered for the gathering of information related to the energetic efficiency. In the second stage, it is analyzed how the energetic consumption results a critical variable in copper production, being the unitarian operation of the concentrator, the one of the most energetic consumption, together with its most important actives, the SAG and Ball mills. Consequently, the study standardized a model to obtain data in the concentrator, thus evaluate the different areas of the organization, according to the characteristics or qualities of the information.